dc.description.resumoO UASB, sigla do inglês Upflow anaerobic sludge blanket, e hoje o sistema mais usado para tratamento anaeróbio de esgoto a taxa elevada. Varias unidades tratando esgoto domestico, em escala real, estão implantadas em diferentes países e mais sistemas estão sendo construídos, prioritariamente, em regiões com clima tropical ou subtropical. No Brasil varias unidades em escala real estão em operação satisfatória tratando efluentes de redes urbanas de esgotos sanitários, sobretudo no Estado do Parana. Diante desta nova realidade o PROSAB - Programa de Saneamento Básico, coordenado pela FINEP - Financiadora de Estudos e Projetos, definiu entre temas prioritários, o tratamento anaeróbio de esgotos domésticos em reatores UASB. Assim, em Campina Grande, esta sendo desenvolvida uma serie de pesquisas com vários conjuntos de reatores tipo UASB, de diferentes configurações e modos operacionais, inclusive associados com outras modalidades de tratamento como lagoas de estabilização. Um dos trabalhos, o de que trata esta dissertação, consistiu da operação de três reatores, em escala piloto, alimentados de forma continua e descontinua, simulando as variações de vazão afluente que podem ser observadas na entrada das estações de tratamento. Considerando que as vazões de esgotamento mudam ao longo do dia e que esta variação pode ser extremamente elevada em função das presenças, por exemplo, de elevatórias dentro do sistema, a montante da unidade de tratamento, o trabalho teve o objetivo de verificar o comportamento de reatores UASB para velocidades ascensionais temporárias significativamente superiores aquelas para as quais foi projetado. O trabalho foi dividido em duas etapas. Na primeira os tres reatores, R l , R2 e R3, trabalharam da seguinte forma: Rl com TDH = 6 h, durante as 24 h consecutivas, R2 com TDH = 3 h em 12 h seguidas e R3 com TDH = 1,5 h por 6 h de funcionamento. Na segunda etapa trabalhou-se com Rl sob TDH = 3 h, durante as 24 h consecutivas, R2 com TDH = 1,5 h em 12 h seguidas e R3 com TDH = 0,75 h por 6 h de funcionamento. Os resultados indicaram que para TDH mini mo de ate 3 h, independente da natureza continua ou não da vazão de alimentação, o desempenho dos reatores era ainda satisfatório e que TDH inferiores a 1,5 h não seriam recomendáveis.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTALpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Civil-
dc.titleEfeito da variação temporal da vazão sobre o desempenho de um reator UASB.pt_BR
dc.date.issued2000-03-30-
dc.description.abstractUASB. acronym of English Upflow anaerobic sludge blanket, is today the system more used for treatment sewer anaerobic the high rate. Several units treating domestic sewer, in real scale, are implanted at different countries and more systems are being built, with great results, in areas with tropical or subtropical climate. In Brazil several units in real scale are in satisfactory operation treating effluents of urban nets of sanitary sewers, above all in the State of Parana. Due to this new reality PROSAB - Programa de Saneamento Basico, coordinated by FINEP - Financiadora de Estudos e Projetos, it defined among themes with priorities, the treatment anaerobic of domestic sewers in reactors UASB. Thus, in Campina Grande, a series of researches is being developed with several groups of reactors type UASB, of different configurations and operational manners, besides associated with other modalities of treatments as ponds of stabilization. One of the works, the that he/she treats this dissertation, it consisted of the operation of three reactors, in pilot scale, feed-dos in a continuous and discontinuous way, simulating the variations of inflow that can be observed in the entrance of the treatment stations. Considering that wastewater flow moves along the day and that this variation it can be extremely elevated in function of the presence, for example, of pumping station inside of the system, to amount of the unit of treatment, the work had the objective significantly of verifying the behavior of reactors UASB for temporary ascendant speeds superiors to those for which it was projected. The work was divided in two stages, where in the first the three reactors, R l , R2 and R3, they worked in the following way: Rl with TDH = 6:00, during 24:00 o'clock serial, R2 with TDH = 3:00 in 12:00 followed and R3 with TDH = 1:30 in 6:00 of operation. In the second stage worked him with Rl under TDH = 3:00, during 24:00 o'clock serial, R2 with TDH = 1:30 in 12:00 followed and R3 with TDH = 0:45 in 6:00 of operation. The results indicated that for minimum TDH of up to 3:00, independent of the continuous nature or not of the feeding flow, the acting of the reactors was still satisfactory and that TDH inferior for 1:30 would not be advisable.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10022-
dc.date.accessioned2019-12-09T20:42:54Z-
dc.date.available2019-12-09-
dc.date.available2019-12-09T20:42:54Z-
dc.typeDissertaçãopt_BR
dc.subjectVariação Temporal-
dc.subjectVazão-
dc.subjectDesempenho de um Reator UASB-
dc.subjectTratamento de Esgoto Doméstico-
dc.subjectTratamento Anaeróbio-
dc.subjectEsgotos Sanitários-
dc.subjectDigestão Anaeróbia-
dc.subjectMetabolismo Bacteriano-
dc.subjectTime Variation-
dc.subjectFlow Rate-
dc.subjectPerformance of a UASB Reactor-
dc.subjectDomestic Sewage Treatment-
dc.subjectAnaerobic Treatment-
dc.subjectSanitary Sewers-
dc.subjectAnaerobic Digestion-
dc.subjectBacterial Metabolism-
dc.rightsAcesso Abertopt_BR
dc.creatorMEDEIROS FILHO, Carlos Fernandes de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeEffect of time flow variation on the performance of a UASB reactor.pt_BR
dc.identifier.citationMEDEIROS FILHO, Carlos Fernandes de. Efeito da variação temporal da vazão sobre o desempenho de um reator UASB. 2000. 106f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Curso de Pós-Graduação em Engenharia Civil, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - PB - Brasil, 2000. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10022pt_BR