Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10147
Full metadata record
DC FieldValueLanguage
dc.creator.IDVIEIRA, F. F.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/1129711375633007pt_BR
dc.contributor.advisor1FRANÇA, Kepler Borges.-
dc.contributor.advisor1IDFRANÇA, K. B.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3620576114544758pt_BR
dc.contributor.referee1FOSSY, Michel François.-
dc.contributor.referee2GOLDFARB, Júlio.-
dc.contributor.referee3ROCHA, José Duarte.-
dc.description.resumoO presente trabalho tem como objetivo avaliar a performance de um equipamento para extração líquido - líquido do tipo misturador - decantador (Mixer-Settler), o qual é constituído de cinco estágios, cada um contendo um misturador e um decantador, interligados entre si por janelas (weirs) que permitem a circulação de ambas as fases. O sistema escolhido para os testes foi: ácido clorídrico 0.10M - Ferro (III) - ácido di-(2-etilhexil) fosfórico (HDEHP ) diluído em hexano, sendo o Ferro (III) o soluto a ser distribuído entre as fases aquosa e orgânica respectivamente. Através do coeficiente de distribuição, foi estudado a influencia da variação da concentração do HDEHP e Ferro (III), para uma razão de volume entre as fases e um fluxo de alimentação constante. Um outro parâmetro investigado foi a influência da razão de volume entre as fases orgânica e aquosa sobre o coeficiente de distribuição quando mantem-se constante a concentração do extratante e do íon Ferro (III) em fase aquosa. Finalmente foi verificado o comportamento da variação da vazão de alimentação da fases orgânica e aquosa com o objetivo de estudar a performance do equipamento, mantendo-se constantes as concentrações do extratante e da espécie metálica em fase aquosa, e a razão de volume entre as duas fases.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Química-
dc.titleAvaliação de um equipamento (protótipo) para extração líquido-líquido.pt_BR
dc.date.issued1989-11-24-
dc.description.abstractThe present work aims to evaluate the performance of a liquid - mixer - decanter (Mixer - Settler) extraction equipment which is It consists of five stages, each containing a mixer and a decanter, interconnected by weirs that allow the circulation of both phases. The system chosen for the tests was: 0.10M hydrochloric acid - Iron (III) - di- (2-ethylhexyl) phosphoric acid (HDEHP) diluted in hexane, with Iron (III) being the solute to be distributed between the aqueous and organic respectively. Through the distribution coefficient, the influence of the variation of the concentration of HDEHP and Iron (III), for a volume ratio between phases and a constant feed flow. Another parameter investigated was the influence of the volume ratio between the organic and aqueous phases on the distribution coefficient when the concentration of the extractant and the iron (III) ion in the aqueous phase remained constant. Finally, it was verified the behavior of the variation of the flow rate of the organic and aqueous phases in order to study the equipment performance, keeping the concentrations of the extractant and the metallic species in the aqueous phase constant, and the volume ratio between the two. phases.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10147-
dc.date.accessioned2019-12-12T12:29:18Z-
dc.date.available2019-12-12-
dc.date.available2019-12-12T12:29:18Z-
dc.typeDissertaçãopt_BR
dc.subjectLíquido - Separação-
dc.subjectExtração Líquido-Líquido-
dc.subjectCoeficiente de Distribuição-
dc.subjectMisturador-Decantador-
dc.subjectSeparação de Metais-
dc.subjectSeparação de Terras Raras-
dc.subjectLiquid - Separation-
dc.subjectLiquid-Liquid Extraction-
dc.subjectDistribution Coefficient-
dc.subjectMixer-Decanter-
dc.subjectMetal Separation-
dc.subjectRare Earth Separation-
dc.rightsAcesso Abertopt_BR
dc.creatorVIEIRA, Fernando Fernandes.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeEvaluation of a equipment (prototype) for liquid-liquid extraction.pt_BR
dc.identifier.citationVIEIRA, Fernando Fernandes. Avaliação de um equipamento (protótipo) para extração líquido-líquido. 1989. 127f. (Dissertação) Mestrado em Engenharia Química, Curso de Mestrado em Engenharia Química, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba - Campus II - Campina Grande - Paraíba - Brasil, 1989. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10147pt_BR
Appears in Collections:Mestrado em Engenharia Química

Files in This Item:
File Description SizeFormat 
FERNANDO FERNANDES VIEIRA - DISSERTAÇÃO PPGEQ CCT 1989.pdfFernando Fernandes Vieira - Dissertação PPGEQ CCT 1989.13.65 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.