Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10215
Full metadata record
DC FieldValueLanguage
dc.creator.IDBATISTA, J. T.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/7812413413221928pt_BR
dc.contributor.advisor1SOARES, José Agnelo.-
dc.contributor.advisor1IDSOARES, J. A.pt_BR
dc.contributor.advisor1IDSOARES, JOSE AGNELO.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3513704271463341pt_BR
dc.contributor.referee1NOGUEIRA, Francisco Cézar Costa.-
dc.contributor.referee2GALVÃO, Carlos de Oliveira.-
dc.description.resumoO presente trabalho analisa o efeito da adoção de diferentes configurações do método da eletrorresistividade para investigar a ocorrência de potenciais aquíferos fissurais em três áreas na região polarizada pelo município de Campina Grande. Nessas áreas reconhecidamente existem zonas de fraturas subverticais no embasamento cristalino, além de rochas alteradas e/ou sedimentos aluviais. A fim de reconhecer tais estruturas potencialmente acumuladoras de água subterrânea foram aplicadas as técnicas de múltiplas sondagens elétricas verticais (SEVs), utilizando o arranjo Schlumberger, e o caminhamento elétrico (CE) utilizando o arranjo gradiente multinível total ou parcial. Diferentes configurações foram testadas em perfis cuja direção é aproximadamente perpendicular aos planos das fraturas e/ou foliação. Os resultados obtidos mostram que o caminhamento elétrico multinível pelo arranjo gradiente apresentou maior clareza na detecção das zonas de fraturas em relação às configurações utilizando sondagens elétricas verticais. No entanto, tais estruturas subverticais ainda poderiam ser detectadas por sondagem elétrica, desde que adotado um afastamento adequado entre os centros das SEVs. As seções geoelétricas obtidas pelas configurações testadas indicam a presença de estruturas acumuladoras de água subterrânea definida pelas anomalias de baixa resistividade elétrica, correlacionáveis a fraturamentos e/ou alterações na permeabilidade do meio. O caminhamento elétrico pelo arranjo gradiente apresenta vantagens operacionais em relação às demais configurações, sendo que o arranjo gradiente total fornece uma imagem de maior resolução que o arranjo gradiente parcial, cuja imagem perde resolução na parte mais rasa da seção geoelétrica.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM EXPLORAÇÃO PETROLÍFERA E MINERALpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqFísica dos Fluidos, Física de Plasmas e Descargas Elétricas.pt_BR
dc.titleAplicação de imageamento elétrico para a locação de poços em aquíferos fissurais na região de Campina Grande, PB.pt_BR
dc.date.issued2019-
dc.description.abstractThe present work analyzes the effect of the adoption of different configurations of the eletroresistivity method to investigate the occurrence of potential fissural aquifers in three areas in the region polarized by the municipality of Campina Grande. In these areas there are subvertical fractures in the crystalline basement, as well as altered rocks and / or alluvial sediments. In order to recognize such potentially groundwater accumulating structures, multiple vertical electric sounding technique (VES) using the Schlumberger array and the electric profiling (EP) using the total or partial multilevel gradient array were applied. Different configurations were tested in profiles whose direction is approximately perpendicular to the planes of fractures and / or foliation. The results obtained show that the multilevel electric profiling through the gradient array showed greater clarity in the detection of fracture zones in relation to the configurations using VES. However, such subvertical structures could still be detected by VES, provided that an adequate spacing between the VES centers was adopted. The geoelectric sections obtained by the tested configurations indicate the presence of accumulating structures of groundwater defined by the anomalies of low electrical resistivity, correlated to fractures and / or changes in the permeability of the medium. The gradient array presents operational advantages in relation to the other configurations, and the total gradient array provides a higher resolution image than the partial gradient array, whose image loses resolution in the shallower part of the geoelectric section.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10215-
dc.date.accessioned2019-12-16T13:48:36Z-
dc.date.available2019-12-16-
dc.date.available2019-12-16T13:48:36Z-
dc.typeDissertaçãopt_BR
dc.subjectHidrogeofísicapt_BR
dc.subjectEletrorresistividadept_BR
dc.subjectEmbasamento Cristalinopt_BR
dc.subjectHydrogeophysicspt_BR
dc.subjectElectric Resistivitypt_BR
dc.subjectCrystalline Basementpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorBATISTA, Juliana Targino.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeApplication of electric imaging for the location of wells in fissural aquifers in the region of Campina Grande, PB.pt_BR
dc.description.sponsorshipCapespt_BR
dc.identifier.citationBATISTA, J. T. Aplicação de imageamento elétrico para a locação de poços em aquíferos fissurais na região de Campina Grande, PB. 2019. 159 f. Dissertação (Mestrado em Exploração Petrolífera e Mineral) – Programa de Pós-Graduação em Exploração Petrolífera e Mineral, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande, Paraíba, Brasil, 2019. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10215pt_BR
Appears in Collections:Mestrado em Exploração Petrolífera e Mineral.

Files in This Item:
File Description SizeFormat 
JULIANA TARGINO BATISTA - DISSERTAÇÃO (PPGEPM) 2019.pdfJuliana Targino Batista - Dissertação PPGEPM CTRN 20196.02 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.