Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10894
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator.ID | LIMA, L. S. C. | pt_BR |
dc.creator.Lattes | http://lattes.cnpq.br/9995684019410436 | pt_BR |
dc.contributor.advisor1 | FREIRE, Raimundo Carlos Silvério. | - |
dc.contributor.advisor1ID | FREIRE, R. C. S. | pt_BR |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/4016576596215504 | pt_BR |
dc.contributor.referee1 | SILVA, João Bosco de Aquino. | - |
dc.contributor.referee2 | MELO, Hiran de. | - |
dc.description.resumo | Uma das maneiras para a avaliação da função pulmonar e a utilização da Técnica de Oscilações Forçadas (TOF). Na sua implementação necessita-se de geradores de pressão que podem ser baseados em alto-falantes. A analise destes geradores e relevante para a determinação da impedância mecânica do sistema respiratório (ZK). A princípio, com a proposta de realizar um estudo sobre a função de transferência de geradores de pressões, surgiu a necessidade de ser verificada a influencia de impedâncias no sistema da TOF. Neste contexto, o objetivo principal deste trabalho de dissertação passou a ser a determinação da influência destas impedâncias em três diferentes estruturas implementadas no sistema. Estas impedâncias são consequências de tubos colocados entre o sistema e a atmosfera. Desta forma, foram realizados experimentos com tubos de diâmetros diferentes para os comprimentos de: 80 e 160 cm. Estes tubos tem como finalidade: permitir a renovação do ar inspirado no sistema, quando posicionado próximo a carga ou ao paciente, e permitir ao cone do alto-falante um melhor movimento, quando posicionados na parte selada e frontal do gerador de pressão. Deste modo, foram efetuadas as medidas dos níveis de pressões no sistema: próximo ao gerador e próximo a carga, objetivando monitorar os níveis de pressões que são gerados, no momento das oscilações forçadas, possibilitando a implementação de sistemas que permitam uma respiração espontânea e sem danos ao paciente. Todo o processo foi efetuado com diferentes geradores de pressões. Com os resultados pode-se concluir que há influência do comprimento, do diâmetro e do posicionamento dos tubos na determinação da impedância mecânica respiratória. Definiu-se também uma melhor estrutura capaz de representar com qualidade a impedância mecânica do sistema, possibilitando uma melhor analise e diagnóstico sobre a função pulmonar. | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Centro de Engenharia Elétrica e Informática - CEEI | pt_BR |
dc.publisher.program | PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA | pt_BR |
dc.publisher.initials | UFCG | pt_BR |
dc.title | Análise de geradores de pressão a alto-falantes utilizados na técnica de oscilações forçadas. | pt_BR |
dc.date.issued | 2003-11-24 | - |
dc.description.abstract | One of the ways to the evaluation of the Pulmonary Function is the use of the Forced Oscillation Technique (FOT). Pressure Generators, which can be based on loudspeakers, are needed in its establishment. The analysis of these generators is important to the determination of the mechanic impedance of the Respiratory System (Zrs). In the beginning, aiming the study about the Transference Function of the pressure generators, the influence of the impedance in the FOT system had to be verified. Based on that, the main objective of this Thesis work became to be the determination of the influence of these impedances which are going to be analysed in three different structures implemented in the System. These impedances are the consequence of tubes put between the system and the atmosphere. In this way, experiments were made using tubes of different diameters to each length of 80 and 160cm. These tubes have the purpose to allow the renewal air inhaled in the System when positioned close to the charge or to the patient, and allow the loudspeaker's cone a better movement when positioned at the frontal part of the pressure generator. In this way, the measures of the levels of pressures in the system were taken: close to the generator and close to the charge, having objective to monitorate the levels of pressures that are generated, at the moment of the Forced Oscillations, making possible the implementation of systems that allow a spontaneous breath and without damages to the patient. The whole process has been accomplished using different pressure generators. Through the results was possible to conclude that there is influence of the length, diameter, and position of the tubes in the determination of the Mechanic Respiratory Impedance. It has also been defined a better structure, able to represent with quality the mechanical impedance of the system, allowing a better analysis and diagnosis about the Pulmonary Function. | pt_BR |
dc.identifier.uri | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10894 | - |
dc.date.accessioned | 2020-01-13T14:16:58Z | - |
dc.date.available | 2020-01-13 | - |
dc.date.available | 2020-01-13T14:16:58Z | - |
dc.type | Dissertação | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.creator | LIMA, Lívia de Souza Camurça. | - |
dc.publisher | Universidade Federal de Campina Grande | pt_BR |
dc.language | por | pt_BR |
dc.title.alternative | Analysis of pressure generators to speakers used in the forced oscillation technique. | pt_BR |
dc.identifier.citation | LIMA, Lívia de Souza Camurça. Análise de geradores de pressão a alto-falantes utilizados na técnica de oscilações forçadas. 91f. (Dissertação de Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2003. | pt_BR |
Appears in Collections: | Mestrado em Engenharia Elétrica. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
LÍVIA DE SOUZA CAMURÇA LIMA - DISSERTAÇÃO PPGEE 2003.pdf | Lívia de Souza Camurça Lima - Dissertação PPGEE 2003 | 7.03 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.