Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10947
Full metadata record
DC FieldValueLanguage
dc.creator.IDCAETANO, M. A. S.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/5656028750243919pt_BR
dc.contributor.advisor1VIEIRA, Maria de Fátima Queiroz.-
dc.contributor.advisor1SOUZA, Benemar Alencar de.-
dc.contributor.advisor1IDVIEIRA, M. F. Q.pt_BR
dc.contributor.advisor1IDSOUZA, B. A.-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1459797138770378pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4987294390789975-
dc.contributor.advisor2SOUZA, Benemar Alencar de.-
dc.contributor.advisor2IDSOUZA, B. A.-
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/4987294390789975-
dc.contributor.referee1BRITO, Nubia Silva Dantas.-
dc.contributor.referee2NEVES, Washington Luiz Araújo.-
dc.description.resumoO uso do formalismo de rede de Petri na modelagem dos sistemas de proteção e controle de uma Usina Hidroelétrica e proposto. O objetivo foi implantar um sistema de diagnóstico de falta em uma Usina visando apoiar o estudo de faltas e apoiar operadores quando da tomada de decisão a qual passa a ser dar com base em um diagnostico mais preciso sobre a causa raiz do desligamento da unidade geradora. O estudo se fundamentou na análise das proteções do sistema, na análise do histórico de faltas do sistema contido nos relatórios de ocorrências e no registro histórico do sistema super visório. Com o uso do aplicativo PIPE ("Plataform Independent Petri Net Editor V4.2.1") foi possível modelar em redes de Petri as principais proteções da usina e verificar a diminuição do numero de alarmes gerado numa ocorrência com desligamento da unidade geradora, que chega a mais de 300 eventos para 5 eventos em uma janela de analise da ocorrência que e de aproximadamente 5 minuto considerando o tempo do disparo da proteção ate a parada total da unidade. A abordagem usando rede de Petri proposto esta limitada em analisar as ocorrências causadas pela o disparo das proteções elétricas.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleModelagem do sistema de proteção e controle de uma usina hidroelétrica para diagnóstico de falta.pt_BR
dc.date.issued2014-10-31-
dc.description.abstractThe use of the formalism of Petri nets in modeling the protection and control systems of a Hydroelectric Power. The objective is to implement a system of fault diagnosis in a power plant to support the study of faults and provide an accurate and objective diagnosis of the root cause of the shutdown of the generating unit, to support operators when making any decision. The study was based on analysis of system protections, the historical analysis of system faults contained in occurrence reports and historical record of the supervisor)' system. Using the PIPE Application ("Platform Independent Petri Net Editor v4.2.1") was possible to model Petri nets the main protections of the plant and verify the reduction of the number of alarms generated in occurrence with shutdown of the generating unit, which reaches more than 300 events to 5 events in an analysis window the event which is approximately five minutes considering the protection tripping time to complete stoppage of the unit. The proposed approach using Petri net is limited in analyzing the events caused by the firing of electrical protections.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10947-
dc.date.accessioned2020-01-14T17:46:05Z-
dc.date.available2020-01-14-
dc.date.available2020-01-14T17:46:05Z-
dc.typeDissertaçãopt_BR
dc.subjectUsina Hidroelétrica-
dc.subjectRedes de Petri-
dc.subjectSistema de Diagnóstico de Falta-
dc.subjectRecomposição do Sistema de Geração-
dc.subjectInteligência Artificial-
dc.subjectHydroelectric Plant-
dc.subjectPetri Nets-
dc.subjectFault Diagnosis System-
dc.subjectGeneration System Recomposition-
dc.subjectArtificial Intelligence-
dc.rightsAcesso Abertopt_BR
dc.creatorCAETANO, Marcos Antônio dos Santos.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeModeling of the protection and control system of a hydroelectric power plant for fault diagnosis.pt_BR
dc.identifier.citationCAETANO, Marcos Antônio dos Santos. Modelagem do sistema de proteção e controle de uma usina hidroelétrica para diagnóstico de falta. 2014. 69 f. Dissertação (Mestrado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2014.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
MARCOS ANTÔNIO DOS SANTOS CAETANO - DISSERTAÇÃO PPGEE 2014.pdfMarcos Antônio dos Santos Caetano - Dissertação PPGEE 20142.71 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.