Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10964
Full metadata record
DC FieldValueLanguage
dc.creator.IDSANTOS, W. R. N.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/9446044529292660pt_BR
dc.contributor.advisor1SILVA, Edison Roberto Cabral da.-
dc.contributor.advisor1IDSILVA, E. R. C.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/7577873305205472pt_BR
dc.contributor.advisor2JACOBINA, Cursino Brandão.-
dc.contributor.advisor2IDJACOBINA, C. B.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/0261885352003041pt_BR
dc.contributor.referee1OLIVEIRA, Alexandre Cunha.-
dc.contributor.referee2CORTIZO, Porfírio Cabaleiro.-
dc.contributor.referee3BARRETO, Luiz Henrique Colado.-
dc.contributor.referee4RIBEIRO, Ricardo Lúcio de Araújo.-
dc.contributor.referee5SANTOS JÚNIOR, Euzeli Cipriano dos.-
dc.description.resumoEste trabalho tem como objetivo estudar as topologias de filtros ativos monofásicos universais e sistemas UPS com redução de componentes. A redução de componentes pode ser obtida a partir da eliminação de urna chave ou um conjunto de chaves estáticas de potencia. Tal feito pode também ser conseguido reduzindo-se a quantidade de elementos passivos presentes no circuito como, por exemplo: capacitores, indutores e transformadores; obtendo-se, dessa forma, redução de peso, custo e volume ocupado. Assim sendo, encontra-se no texto um estudo sobre filtros ativos monofásicos universais com quatro, três e dois braços incluindo os circuitos de potencia, de controle, as equações e as curvas que descrevem o comportamento dinâmico e de regime permanente, os custos de implementação e as análises de perdas dos sistemas propostos. Algumas configurações de filtros ativos foram escolhidas para operarem com um banco de baterias conectado ao barramento c.c. a partir de um conversor c.c, funcionando, dessa forma, como sistema UPS (fonte de alimentação ininterrupta), em caso de falta na fonte primaria de alimentação c.a.. Como o foco do trabalho e desenvolver estruturas com número reduzido de componentes, desenvolveram-se estruturas que emulam os conversores buck e boost fazendo-se uma comutação no modo de operação dos conversores dos filtros ativos, deixando-se um dos braços livres para carregar ou para elevar a tensão no banco de baterias quando necessário. Os resultados obtidos são comprovados através de simulações digitais e experimentação com os protótipos montados no laboratório.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleFiltros ativos monofásicos e sistemas UPS com redução do número de componentes.pt_BR
dc.date.issued2010-12-10-
dc.description.abstractThis work aimed to study topologies of single phase universal active filters and UPS systems with a reduced number of components. The reduction of components may be obtained from the elimination of one or a set of power static switch. This fact can also be achieved by reducing the number of passive elements presented in the power circuit such as capacitors, inductors, transformers in order to reduce weight, cost and volume. As part of this work, the studies of single-phase active power filters with four or three or two legs including the power circuits, control circuits, their analysis and corresponding equations and curves that describe the dynamic and the steady state response, the implementation costs and the power losses of the systems are shown. Some configurations of single-phase power filters have been chosen to operate with a battery bank connected to the d.c. bus from the d.c. converter, working as UPS (Uninterruptible Power Supply) systems in case of failure in a.c. power supply. As the focus of this work is to develop structures with reduced number of components, some structures that emulate the buck and boost converters are developed. They work by change the mode of operation of the filter's converters making them with one-leg free to load or to raise the voltage at the battery bank when necessary. The results arc demonstrated by digital simulations and experimentation with prototypes assembled in the laboratory.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10964-
dc.date.accessioned2020-01-15T15:09:33Z-
dc.date.available2020-01-15-
dc.date.available2020-01-15T15:09:33Z-
dc.typeTesept_BR
dc.subjectFiltro Ativo Monofásico-
dc.subjectFonte de Alimentação Ininterrupta-
dc.subjectRedução de Componentes-
dc.subjectSistema UPS-
dc.subjectCircuito de Potência-
dc.subjectSingle Phase Active Filter-
dc.subjectUninterruptible Power Supply-
dc.subjectComponent Reduction-
dc.subjectUPS System-
dc.subjectPower Circuit-
dc.rightsAcesso Abertopt_BR
dc.creatorSANTOS, Welflen Ricardo Nogueira.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeSingle phase active filters and UPS systems with reduced component count.pt_BR
dc.identifier.citationSANTOS, Welflen Ricardo Nogueira. Filtros ativos monofásicos e sistemas UPS com redução do número de componentes. 2010. 211 f. Tese (Doutorado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2010.pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
WELFLEN RICARDO NOGUEIRA SANTOS - TESE PPGEE 2010.pdfWelflen Ricardo Nogueira Santos - Dissertação PPGEE 201010.78 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.