dc.description.resumoAs agendas reguladoras e o grau de exigência dos consumidores fazem com que as empresa de energia elétrica busquem aumentar a sua confiabilidade. Assim o monitoramento dos equipamentos elétricos torna-se essencial neste contexto. As técnicas de medição das descargas parciais tem sido usadas no monitoramento do envelhecimento dos equipamentos elétricos. Descargas Parciais são descargas elétricas que curto-circuitam parte da isolação entre dois condutores. A constatação da sua presença pode identificar situações danosas para a isolação de um equipamento submetido a alta tensão. Para se ter um diagnostico adequado sobre os efeitos danosos dos sinais de descargas parciais, não apenas se deve quantificar a descarga parcial, mas também medir a amplitude, frequência, taxa de repetição, dentre outros. Uma medição ideal dos parâmetros essenciais presentes nos sinais de descargas parciais e obtida quando o detector de descargas parciais tem a capacidade de não distorcer ou atenuar estes parâmetros. Como os sinais de descargas parciais são pulsos de alta frequência, neste trabalho e projetado e implementado um detector de banda larga, formado por um impedor de 50 Q e um amplificador com faixa de passagem de 50 MHz e frequência de corte inferior de 2,75 MHz. São realizados ensaios de geração, detecção e medição dos sinais de descargas parciais. A validação dos resultados e feita com a comparação entre os resultados obtidos nos ensaios realizados com um detector comercial e o desenvolvido.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleProjeto e implementação de um circuito para detecção de sinais de descargas parciais.pt_BR
dc.date.issued2003-04-04-
dc.description.abstractThe electric energy regulatory agencies and the consumer requirements propitiate that the electric energy companies increase its confiability. Thus, the electric equipments monitoring become essential in this context. The partial discharge measurement techniques have been used in electric equipment ageing monitoring. Partial discharges are electric discharges that only partially bridge the insulation between conductors. The partial discharges presence can identify prejudicial situations to the equipment insulation submitted to high voltages. To obtain an adequate diagnostic about the prejudicial effects of the partial discharge signals, it must quantify the discharges and also measure its magnitude, frequency, repetition rates, among others. An ideal measurement of the essential parameters present in the partial discharge signals is obtained when the partial discharge detector has capacity of not distort and attenuate these parameters. As the partial discharge signals are high frequency pulses, in this work, a large band detector is projected and implemented. It is composed for a 50 Q impedance and an 50 MHz passband amplificator with a 2,75 MHz cutoff frequency. The partial discharge generation, detection and measurement tests are accomplished. The obtained results using the commercial and the developed detector are compared.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10973-
dc.date.accessioned2020-01-15T18:15:39Z-
dc.date.available2020-01-15-
dc.date.available2020-01-15T18:15:39Z-
dc.typeDissertaçãopt_BR
dc.subjectImpedor de Medição-
dc.subjectDescargas Parciais-
dc.subjectAmplificador de Banda Larga-
dc.subjectMétodos de Detecção-
dc.subjectCircuitos-
dc.subjectMeasurement Stopper-
dc.subjectPartial Discharges-
dc.subjectBroadband Amplifier-
dc.subjectDetection Methods-
dc.subjectCircuits-
dc.rightsAcesso Abertopt_BR
dc.creatorMEDEIROS, Maria Aparecida Alves de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeDesign and implementation of a circuit for detection of partial discharge signals.pt_BR
dc.identifier.citationMEDEIROS, Maria Aparecida Alves de. Projeto e implementação de um circuito para detecção de sinais de descargas parciais. 2003. 100 f. Dissertação ( Mestrado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2003.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
MARIA APARECIDA ALVES DE MEDEIROS - DISSERTAÇÃO PPGEE 2003.pdfMaria Aparecida Alves de Medeiros - Dissertação PPGEE 200312.38 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.