dc.description.resumoO presente trabalho tem como objetivo estudar a normalização de dois sistemas de dessalinização via osmose inversa, instalados nas localidades de Riacho de Santo Antonio e Catingueira, ambos no Estado da Paraíba, alimentados com água de 13.665 mg/L e 945 mg/L de sólidos totais dissolvidos (STD), respectivamente. A partir dos dados das variáveis de medidas dos sistemas como vazão, pressão, temperatura, condutividade e concentração, efetuou-se uma serie de cálculos para observar o desempenho dos sistemas. Foram avaliados os seguintes parâmetros normalizados: vazão do permeado, gradiente de pressão efetiva media (NDP), STD do permeado, passagem e rejeição de sais e o coeficiente de transferência de massa (CTM). Apos a normalização dos dados foi realizado um estudo dos tipos de incrustações que poderiam estar ocorrendo nos sistemas, O resultado para o sistema localizado em Catingueira-PB foi: diminuição de 13% na vazão do permeado; aumento de 16% na TDP; aumento no STD de 48%; aumento de 71% na passagem de sais; diminuição de 30% no CTM e os cálculos de prevenção de incrustações indicou uma tendencia a incrustações de CaCOs e CaSd. O resultado para o sistema localizado em Riacho de Santo Antônio-PB foi: diminuição de 7% na vazão do permeado; aumento de 7% na TDP; aumento no STD de 34%; aumento de 50% na passagem de sais; diminuição de 11% no CTM e os cálculos de prevenção de incrustações indicou uma tendencia a incrustações de CaCO3.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.titleNormalização de sistemas de dessalinização via osmose inversa.pt_BR
dc.date.issued2003-09-
dc.description.abstractThe present work has as objective studies the normalization of two desalination systems via reverse osmosis, installed in the Riacho de Santo Antonio and Catingueira, both in the State of Paraiba, with feed water of 13.665 mg/L and 945 mg/L total of dissolved solids (TDS), respectively. Starting from the data of the variables of measures of the systems as; flow, pressure, temperature, conductivity and concentration, making a series of calculations to observe the peformance of the systems. The evaluate parameters were: flow of the permeate, net driving pressure (NOP), TDS of the permeate, salt passage and salt rejection and the mass transfer coefficient (MTC). After the normalization was accomplished a study of the scalings types that could be happening in the systems. The result for the system of Catingueira-PB was: decrease of 13% in the flow of the permeate; increase of 16% in NDP; increase in TDS of 48%; increase of 71% in the salts passage ; decrease of 30% in MTC and the calculations of scalings prevention indicated a tendency to the scaling of CaCCb and CaS04. The result for the system of Riacho de Santo Antdnio- PB was: decrease of 7% in the flow of the permeate; increase of 7% in NDP; increase in TDS of 34%; increase of 50% in the salts passage; decrease of 11% in MTC and the calculations of scalings prevention indicated a tendency to the scaling of CaCO;*.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11049-
dc.date.accessioned2020-01-20T13:33:23Z-
dc.date.available2020-01-20-
dc.date.available2020-01-20T13:33:23Z-
dc.typeDissertaçãopt_BR
dc.subjectOsmose Inversa-
dc.subjectNormalização-
dc.subjectDessalinização-
dc.subjectMembranas-
dc.subjectIncrustação-
dc.subjectLimpeza Química-
dc.subjectReverse Osmosis-
dc.subjectNormalization-
dc.subjectDesalination-
dc.subjectMembranes-
dc.subjectInlay-
dc.subjectChemical Cleaning-
dc.rightsAcesso Abertopt_BR
dc.creatorSOUSA, Shefora Elisangela Henriques de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeNormalization of desalination systems via reverse osmosis.pt_BR
dc.identifier.citationSOUSA, Shefora Elisangela Henriques de. Normalização de sistemas de dessalinização via osmose inversa. 2003. 128f. (Dissertação de Mestrado em Engenharia Química), Programa de Pós-graduação em Engenharia Química, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande - Paraíba - Brasil, 2003. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11049pt_BR
Appears in Collections:Mestrado em Engenharia Química

Files in This Item:
File Description SizeFormat 
SHEFORA ELISANGELA HENRIQUES DE SOUSA - DISSERTAÇÃO PPGEQ CCT 2003.pdfShefora Elisangela Henriques de Sousa - Dissertação PPGEQ 2003. 8.2 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.