dc.description.resumoFaltas de alta impedância (FAI) são distúrbios graves e preocupantes nos sistemas de distribuição de energia elétrica. Devi do aos baixos níveis de corrente de falta, os principais dispositivos de proteção desses sistemas não são capazes de diagnosticá-las com precisão. Neste sentido, métodos de detecção e localização de FAI vêm sendo foco de interesse de muitas pesquisas. Tais métodos são, muitas vezes, validados com auxilio de simulações computacionais. Quanta mais próximo estes modelos consigam chegar das características encontradas no fenômeno real, mais confiáveis serão os algoritmos de diagnostico neles baseados. Desta forma, neste trabalho e apresentado um modelo de FAI que apresenta as principais características das correntes de falta deste distúrbio, tais como: baixos níveis de sobrecorrente, assimetria entre os semiciclos, não-linearidade, buildup, shoulder e intermitência. O modelo se baseia em oscilografias reais de FAI obtidas em ensaios de campo. As simulações foram realizadas no software ATP e o modelo foi implementado usando a linguagem MODELS. O modelo leva em consideração o tipo de superfície de contato, e contempla um número maior de características do que os modelos estudados. Com uma modelagem especifica para cada tipo de superfície, uma base de dados foi criada, na qual os arquivos finais foram convertidos para o padrão IEEE COMTRADE. Esse padrão e utilizado pela maioria dos RDP, qualímetros e reles oscilográficos do sistema elétrico, permitindo assim, que dados reais sejam inseridos a base de dados simulados sem a necessidade de nenhum tipo de conversão de formato.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleUma revisão de modelos clássicos de faltas de alta impedância para efeito de melhoramento.pt_BR
dc.date.issued2011-09-09-
dc.description.abstractHigh impedance faults (HIF) are serious and troubling disturbances in distribution systems of electric power. Due to their fault current low levels, the main power system protection devices are not able to diagnose them accurately. In this sense, HIF detection and location methods have been the focus of many researches. Such methods are often validated with the aid of computer simulations. The closer these models can reach the characteristics found in real phenomenon, the more reliable will be the diagnostic algorithms based on them. Thus, this paper presents a model of HIF which takes into account the main fault currents characteristics of the disturbance, such as: low levels of overcurrent, asymmetry between the half-cycles, nonlinearity, buildup, shoulder, and intermittence. The model is based on actual HIF oscillographic data obtained in field tests. Simulations were performed in ATP software and the model was implemented by using MODELS. At the end, it was obtained a model that takes into account the type of contact surface, and simulates a larger number of features than the evaluated models. With a specific model for each type of surface, it was created a database composed of records with IEEE COMTRADE standard. This pattern is used for most digital fault recorders (DFRs), qualimeters, and relays of the electrical system, allowing, in this way, actual data to be inserted to the simulated database without needing any kind of format conversion.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11061-
dc.date.accessioned2020-01-20T18:37:20Z-
dc.date.available2020-01-20-
dc.date.available2020-01-20T18:37:20Z-
dc.typeDissertaçãopt_BR
dc.subjectFaltas de Alta Impedância-
dc.subjectBanco de Dados-
dc.subjectEnsaios de Campo-
dc.subjectModelagem de Falta-
dc.subjectTransitórios Eletromagnéticos-
dc.subjectHigh Impedance Fault-
dc.subjectDatabase-
dc.subjectField Tests-
dc.subjectFault Modeling-
dc.subjectElectromagnetic Transients-
dc.rightsAcesso Abertopt_BR
dc.creatorSANTOS, Wellinsílvio Costa dos.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeA review of classic models of high impedance faults for improvement purposes.pt_BR
dc.identifier.citationSANTOS, Wellinsílvio Costa dos. Uma revisão de modelos clássicos de faltas de alta impedância para efeito de melhoramento. 2011. 75 f. Dissertação (Mestrado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande, Paraíba, Brasil, 2011.pt_BR