dc.description.resumoA medição e análise harmônica da resistiva tem sido usadas como parâmetros no monitoramento nos para-raios de oxido de zinco (ZnO). Os pára-raios a base de ZnO são formados por varistores, elementos que apresentam alta não-linearidade entre a tensão e a corrente. A medição da componente resistiva da corrente de fuga total sera realizada utilizando-se o método de compensação capacitiva diferencial virtual - método da ponte virtual desenvolvido neste trabalho. A nova abordagem propõe a eliminação física do capacitor de compensação da ponte diferencial capacitiva. Com o objetivo de validar a analise harmônica da corrente resistiva, como parâmetro eficaz no monitoramento dos para-raios, varistores de ZnO novos serão degradados paulatinamente com aplicação de sobretensão alternada e impulsos de corrente. Antes e apos os ensaios de degradação efetuam-se medições da corrente de fuga resistiva. Figura 2.50s resultados obtidos nos ensaios experimentais e nas simulações demonstram que o método da ponte virtual desenvolvida neste trabalho e eficiente nas medições e na determinação da corrente resistiva e suas harmônicas. Também se constatou que a corrente resistiva e a componente de 3a harmônica são os parâmetros que mais evidenciam a degradação dos varistores.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleMedição e análise harmônica da corrente de fuga resistiva em varistores de ZNO.pt_BR
dc.date.issued2004-08-31-
dc.description.abstractThe measurement and the harmonic analysis of the resistive leakage current is an efficient technique for determining the degradation level of metal oxide surge arresters. The arrester consists of a stack of nonlinear resistive blocks known as varistors. A novel technique for determining the resistive component of the leakage current of ZnO varistors has been presented. It consists of a virtual bridge that does not require a high voltage coupling capacitor. The proposed technique has been applied to monitor the resistive leakage current of ZnO varistors that have been degraded under controlled conditions. The degradation has been obtained by applying high voltages and high impulses current discharges. The resistive waveform has been measured before and after the degradation of the varistors. Measurements and simulations are presented and they show that the 3rd harmonic component of the resistive leakage current is a good indicator of the level degradation of the ZnO varistors.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11131-
dc.date.accessioned2020-01-22T18:18:37Z-
dc.date.available2020-01-22-
dc.date.available2020-01-22T18:18:37Z-
dc.typeDissertaçãopt_BR
dc.subjectAnálise Harmônica-
dc.subjectPara-raios-
dc.subjectPonte Virtual-
dc.subjectSupressores de Surto-
dc.subjectÓxido de Zinco - ZNO-
dc.subjectHarmonic Analysis-
dc.subjectLightning Rod-
dc.subjectVirtual Bridge-
dc.subjectOutbreak Suppressors-
dc.subjectZinc Oxide - ZNO-
dc.rightsAcesso Abertopt_BR
dc.creatorSOUZA, Ronimack Trajano de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeHarmonic leakage current measurement and analysis in ZNO varistors.pt_BR
dc.identifier.citationSOUZA, Ronimack Trajano de. Medição e análise harmônica da corrente de fuga resistiva em varistores de ZNO. 2004. 87 f. Dissertação (Mestrado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2004.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.