Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11159
Full metadata record
DC FieldValueLanguage
dc.creator.IDCARVALHO JÚNIOR, R. O.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/7320244516732073pt_BR
dc.contributor.advisor1JACOBINA, Cursino Brandão.
dc.contributor.advisor1LIMA, Antonio Marcus Nogueira.
dc.contributor.advisor1IDJACOBINA, C. B.pt_BR
dc.contributor.advisor1IDLIMA, A. M. N.
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0261885352003041pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2237395961717699
dc.contributor.referee1SILVA, Edison Roberto Cabral da.
dc.contributor.referee2SOUZA FILHO, Eurico Bezerra de.
dc.description.resumoNeste trabalho são estudados a modelagem e o controle de corrente de sistemas de eletrônica de potência trifásicos desequilibrados (a três fios). Neste estudo o sistema trifásico é convertido em um equivalente bifásico facilitando o estudo do comportamento de regime transitório e permanente de cargas apresentando desequilíbrios. O modelo bifásico resultante e apropriado para a determinação de uma estrategia de controle para sistemas desequilibrados. A estrategia de controle proposta e derivada de um esquema contendo um duplo controlador empregando uma malha de controle para as variáveis de sequência positiva e uma outra malha para a sequência negativa. A estrutura de controle proposta e mais simples do que o esquema de duplo controlador, a qual baseia-se em um único controlador para as variáveis de sequência positiva e negativa. São consideradas duas leis de controle, uma baseada no controlador PI e a outra baseada no controlador PID. Estes controladores são apresentados no referencial síncrono como também no referencial estacionário. Uma extensão da estratégia de controle diz respeito a matrizes de transformação de coordenada nas quais convertem um sistema desequilibrado em um sistema bifásico desacoplado dependendo do tipo de desequilíbrio. Esta lei de controle pode também ser implementada no referencial estacionário. Neste trabalho também e discutida uma estrutura de controle de corrente destinada a rejeição de harmônicos em sistemas trifásicos contendo componentes harmônicas de baixa frequência. As leis de controle propostas são implementadas em um sistema baseado em um micro computador, contendo placas de interface dedicadas para o controle em tempo real. Para comprovar a validade e eficácia da metodologia proposta são apresentados resultados experimentais e de simulação.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica
dc.titleControle de corrente digital de sistemas de potência desequilibrados contendo conversores estáticos.pt_BR
dc.date.issued2000-05-26
dc.description.abstractThis work aims of examine the modelling and control of unbalanced three-phase threewire power electronic systems. The three-phase sj-stera is converted into an equivalents two-phase system to represent the transient and steady-state behavior of unbalanced loads being supplied by PWM converters. The definition of the current control strategy for the unbalanced system is based on the equivalent two-phase model. The control strategy proposed is derived from the double controller scheme that employs one controller for the positive sequence and another for the negative sequence. The controller structure is simpler than the double controller scheme in which is based on a single controller for the positive and negative sequences. Two types of controllers are discussed, one based on the PI approach and another based on the PID approach. Both controllers can be implemented digitally in the stationary reference frame. An extension of the control strategy concerns coordinate transformation matrices in which convert the unbalanced system into an equivalent decoupled two-phase system depending on the type of unbalancing. This controller can also be Implemented in the stationary refence frame. The current control considering the presence of low frequency harmonic in the system is also addressed. The proposed control laws are implemented in a microcomputer- based system at the stationary reference frame. The simulation and experimental results demonstrate the validity of the proposed methodology.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11159
dc.date.accessioned2020-01-23T15:59:57Z
dc.date.available2020-01-23
dc.date.available2020-01-23T15:59:57Z
dc.typeDissertaçãopt_BR
dc.subjectControle de Corrente
dc.subjectAcionamento Estático
dc.subjectMáquina de Indução Assíncrona
dc.subjectSistemas de Potência
dc.subjectConversores
dc.subjectCurrent Control
dc.subjectStatic Drive
dc.subjectAsynchronous Induction Machine
dc.subjectPower Systems
dc.subjectConverters
dc.rightsAcesso Abertopt_BR
dc.creatorCARVALHO JÚNIOR, Rui Oliveira de.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeDigital current control of unbalanced power systems containing static converters.pt_BR
dc.identifier.citationCARVALHO JÚNIOR, Rui Oliveira de. Controle de corrente digital de sistemas de potência desequilibrados contendo conversores estáticos. 2000. 142 f. Dissertação (Mestrado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande, Paraíba, Brasil, 2000. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11159pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
RUI OLIVEIRA DE CARVALHO JÚNIOR - DISSERTAÇÃO PPGEE 2000.pdfRui Oliveira de Carvalho Júnior - Dissertação PPGEE 20007.84 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.