Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1123
Full metadata record
DC FieldValueLanguage
dc.creator.IDPRATA, L. S.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/9234155610858935pt_BR
dc.contributor.advisor1MENEZES, Romualdo Rodrigues.-
dc.contributor.advisor1IDMENEZES, R. R.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1169292996645931pt_BR
dc.contributor.advisor2FOOK, Marcus Vinícius Lia.-
dc.contributor.advisor2IDFOOK, M. V. L.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/4149843752530120pt_BR
dc.contributor.referee1FREIRE, Waldênia Pereira.-
dc.contributor.referee2PINTO, Maria Roberta de Oliveira.-
dc.description.resumoApós alerta sanitário emitido pela Agencia Francesa de Segurança Sanitária de Produtos de Saúde (AFFSAPS) de não conformidades no silicone utilizado para fabricação de próteses mamárias da empresa Poly Implant Prothese (PIP), a Agência Nacional de Vigilância Sanitária (ANVISA) publicou regulamentação estabelecendo a necessidade de certificação no âmbito do Sistema Brasileiro de Avaliação da Conformidade (SBAC) segundo parâmetros de Portaria do Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO) para avaliação de conformidade para Implantes Mamários. Dentre outros requisitos foi estabelecida a obrigatoriedade de observação das condições descritas na referida portaria. Neste trabalho foram avaliadas amostras de próteses mamárias de silicone de um mesmo fabricante, com as mesmas especificações, variando apenas o número dos lotes. Observaram-se as características macroscópicas das amostras como variáveis para a realização de ensaios normatizados. Foram comparadas características das amostras como rugosidade, cor, consistência, deformação, aderência ao elastômero, adesividade do gel e comportamento mecânico das membranas quando submetidas ao ensaio de tração. Embora tenham sido avaliadas próteses com as mesmas especificações de fabrica, foram observadas diferenças nas características macroscópicas das amostras e na resistência à tração. Quando avaliados em conjunto, os dados demonstram discrepâncias nas características das amostras e inconformidades com as normas estabelecidas.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM CIÊNCIA E ENGENHARIA DE MATERIAISpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia de Materiaispt_BR
dc.titleAvaliação de próteses mamárias quanto às características macroscópicas e resistência à tração.pt_BR
dc.date.issued2015-02-06-
dc.description.abstractAfter health alert issued by the French Agency for Sanitary Safety of Health Products (AFFSAPS) of non-compliance in the silicone used for the manufacture of breast implants the company Poly Implant Prothese (PIP), the Brazilian Health Surveillance Agency (ANVISA) has published regulations establishing certification requirement under the Brazilian System of Conformity Assessment (SBAC) within the parameters of Ordinance of the National Institute of Metrology, Quality and Technology (Inmetro) for conformity assessment to Breast Implants. Among other requirements the obligation to observe the conditions described in the said ordinance was established. In this work we were evaluated samples of silicone breast implants from the same manufacturer with the same specifications, varying only the number of lots. Were observed in the macroscopic characteristics of the samples as variable for performing standardized tests. Sample characteristics were compared as roughness, color, consistency, deformation, adhesion to the elastomer, gel adhesive and mechanical behavior of the membrane when subjected to tensile test. Although dentures have been evaluated with the same specifications of manufactures, differences were observed in macroscopic characteristics of the samples and tensile strength. When evaluated together, the data show differences in the characteristics of samples and noncompliance with established standards.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1123-
dc.date.accessioned2018-07-09T15:49:08Z-
dc.date.available2018-07-09-
dc.date.available2018-07-09T15:49:08Z-
dc.typeDissertaçãopt_BR
dc.subjectSiliconept_BR
dc.subjectPróteses Mamáriaspt_BR
dc.subjectANVISApt_BR
dc.subjectINMETROpt_BR
dc.subjectBreast Implantpt_BR
dc.subjectResistência à tração - próteses mamáriaspt_BR
dc.subjectTraction resistance - breast implantsen
dc.rightsAcesso Abertopt_BR
dc.creatorFONSECA, Letícia Seixas Prata da.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.identifier.citationFONSECA, L. S. P. da. Avaliação de próteses mamárias quanto às características macroscópicas e resistência à tração. 2015. 40 f. Dissertação (Mestrado em Ciência e Engenharia de Materiais) – Programa de Pós-Graduação em Ciência e Engenharia de Materiais, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1123pt_BR
Appears in Collections:Mestrado em Ciência e Engenharia de Materiais.

Files in This Item:
File Description SizeFormat 
LETÍCIA SEIXAS PRATA DA FONSECA - DISSERTAÇÃO PPG-CEMat CCT 2015.pdfLetícia Seixas Prata da Fonseca - Dissertação PPG-CEMat CCT 2015997.96 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.