Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11303
Full metadata record
DC FieldValueLanguage
dc.creator.IDSOUZA, J.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/3941210590487917pt_BR
dc.contributor.advisor1OLIVEIRA, Rui de.-
dc.contributor.advisor1IDOLIVEIRA, R.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0621382505832223pt_BR
dc.contributor.advisor2COURA, Mônica de Amorim.-
dc.contributor.advisor2IDCOURA, M. A.-
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/8234481367230599-
dc.contributor.referee1MEIRA, Celeide Maria Belmont Sabino.-
dc.contributor.referee2DUARTE, Valderi Leite.-
dc.description.resumoEste trabalho teve por objetivo verificar o grau de conformidade da qualidade da água do sistema de abastecimento de Campina Grande (7°13'50" Sul e 35°52'52"Oeste), estado da Paraíba, Nordeste do Brasil, com o padrão de aceitação para consumo humano, de acordo com a Portaria do Ministério da Saúde 518/2004, com base nos indicadores selecionados, alumínio, cloreto, dureza, ferro, manganês e turbidez. Foram amostrados seis pontos em três diferentes horários do ciclo diário, no período de marco a dezembro de 2009, nas zonas de pressão A e B da rede de distribuição de água. A escolha desses pontos estratégicos foi feita seguindo os critérios definidos pela Diretriz Nacional do Piano de Amostragem da Vigilância em Saúde relacionada a qualidade da água para consumo humano. A aplicação de analise de variância de fator único aos vários conjuntos de dados amostrais de uma mesma variável demonstrou que as variações de comportamento dos indicadores não dependem do horário, mas do ponto de monitoração. Dos indicadores analisados somente alumínio (62,12%) e turbidez (3,42%) apresentaram não conformidade com o supramencionado padrão de aceitação sendo tais não conformidades atribuídas as alterações da qualidade da água bruta do manancial no período chuvoso e a um esquema operacional da estação de tratamento de água sem flexibilidade para responder a essas mudanças. Assim, numa estação de tratamento que ordinariamente não utiliza agente coagulante durante a estação seca, o inicio da estação chuvosa trazendo significativo aumento de turbidez a água, provoca como resposta uma dosagem do coagulante, sulfato de alumínio, que, sem o acompanhamento de um controle rigoroso das condições ótimas para o desempenho das operações de clarificação, tende a ultrapassar a sua real demanda e deixar um residual de alumínio que ultrapassa o valor máximo permissível padronizado de 0,2mgAI/L.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTALpt_BR
dc.publisher.initialsUFCGpt_BR
dc.titleConformidade da água de abastecimento de Campina Grande (PB) com o padrão de aceitação para o consumo humano.pt_BR
dc.date.issued2010-03-
dc.description.abstractThis study aimed to verify compliances and non-compliances of the water indicators, aluminum, chloride, hardness, iron, manganese and turbidity with the standard of acceptance for human consumption, according Brazilian Ministry of Health Ordinance 518/2004, of water distributed at pressure zones A and B of water network of Campina Grande (7°13'50" S and 35°52'52"W), Paraiba state, northeast Brazil. Samples from six monitoring points were collected at three distinct times within the daily cycle from March to December 2009. These points were chosen according the criteria established in the National Guidance for the Sampling Plan on Health Surveillance related with water quality for human consumption. The application of one-factor analysis of variance (ANOVA) to the various data sets from monitoring of a same variable demonstrated that variations in the behavior of indicators were dependent on the position of sampling point rather than on time collection. From all indicators analyzed only aluminium (62.12%) and turbidity (3.42%) presented noncompliances with the already mentioned standard for human consumption acceptance, being these non-compliances related with both changes in raw water stored at the reservoir in rainy season and a water treatment plant operation schedule without flexibility to work with those changes. Ordinarily, none coagulation chemical agent is used during dry season, but from the beginning of rainy season aluminium sulphate is dosed in order to face up the significant increase on turbidity in raw water. But, without a rigorous control of factors which promote an optimal clarification, coagulant dosage tend to overlap its real demand and leave a residue of aluminium in the water which is more than the standardized maximum permissible concentration of 0.2mgAI/L.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11303-
dc.date.accessioned2020-01-29T10:16:10Z-
dc.date.available2020-01-29-
dc.date.available2020-01-29T10:16:10Z-
dc.typeDissertaçãopt_BR
dc.subjectÁgua - Abastecimento-
dc.subjectÁgua - consumo Humano-
dc.subjectVigilância da Água-
dc.subjectAlumínio na Água-
dc.subjectQualidade da Água-
dc.subjectWater - Supply-
dc.subjectÁgua - Human Consumption-
dc.subjectMonitoring of Water-
dc.subjectAluminum in Water-
dc.subjectWater Quality-
dc.rightsAcesso Abertopt_BR
dc.creatorSOUZA, Joseneto de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeCompliance of the water supply in Campina Grande (PB) with the acceptance standard for human consumption.pt_BR
dc.identifier.citationSOUZA, Joseneto de. Conformidade da água de abastecimento de Campina Grande (PB) com o padrão de aceitação para o consumo humano. 2010. 92f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Programa de Pós-Graduação em Engenharia Civil e Ambiental, Universidade Federal de Campina Grande - Paraíba - Brasil, 2010. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11303pt_BR
Appears in Collections:Mestrado em Engenharia Civil e Ambiental.

Files in This Item:
File Description SizeFormat 
JOSENETO DE SOUZA - DISSERTAÇÃO PPGECA 2010.pdfJoseneto de Souza - Dissertação PPGECA 2010. 9.63 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.