Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11343
Title: Otimização de metodologia analítica utilizando resina de troca iônica para abrandamento de água do “poço 1” que abastece a cidade de Nova Floresta - PB.
Other Titles: Optimization of analytical methodology using ion exchange resin to soften water from “well 1” that supplies the city of Nova Floresta - PB.
Optimización de la metodología analítica utilizando resina de intercambio iónico para el ablandamiento del agua del "pozo 1" que abastece a la ciudad de Nova Floresta - PB.
???metadata.dc.creator???: FONSECA, Clarissa Dayanne Medeiros da.
???metadata.dc.contributor.advisor1???: SILVA, Denise Domingos da.
???metadata.dc.contributor.referee1???: SILVEIRA, Gleba Coelli Luna da.
???metadata.dc.contributor.referee2???: SANTOS, Cláudia Patrícia Fernandes dos.
Keywords: Água de abastecimento;PH;Condutividade;Abrandamento;Resina de troca-iônica;Water supply;Conductivity;Relaxation;Ion-exchange resin;Suministro de agua;Conductividad;Relajación
Issue Date: 22-Nov-2011
Publisher: Universidade Federal de Campina Grande
Citation: FONSECA,Clarissa Dayanne Medeiros da. Otimização de metodologia analítica utilizando resina de troca iônica para abrandamento de água do “poço 1” que abastece a cidade de Nova Floresta - PB. 2011. 74 fl. (Trabalho de Conclusão de Curso – Monografia), Curso de Licenciatura em Química, Centro de Educação e Saúde, Universidade Federal de Campina Grande, Cuité – Paraíba – Brasil, 2011.
???metadata.dc.description.resumo???: Este trabalho teve como principal objetivo otimizar metodologia analítica no abrandamento por cromatografia de troca iônica de água do poço, identificado, por conveniência, como “Poço 1”, realizando um estudo através da avaliação das propriedades físico-químicas da amostra (pH, condutividade e dureza) e do desempenho da regeneração da resina, recheio da coluna cromatográfica, em seu tratamento. Para as medidas de pH, utilizou-se um potenciômetro digital, pH METER MODEL e a condutância foi analisada por um condutivímetro digital Mca 150. Na determinação da dureza total da amostra, utilizou-se a Volumetria de Complexação, com solução de EDTA como titulante complexométrico. Antes de passar pela resina de troca iônica, os resultados obtidos para as medidas de pH (5,56), que indicam uma considerável acidez da amostra, apontaram para a não conformidade com os padrões estabelecidos pela resolução 357/2005 do CONAMA (CONSELHO NACIONAL DO MEIO AMBIENTE), que determina que as águas destinadas ao abastecimento e ao consumo humano, devem possuir pH na escala de 6,0 a 9,0. A condutividade da amostra foi de 181,85 mS. Em relação à dureza, a amostra se classifica como uma amostra de dureza média, com 70, 063 mg de CaCO3/L . Após passar pela resina de troca iônica, regenerada com solução alcalina, o pH da amostra apresenta caráter alcalino, acompanhado de uma diminuição da condutividade e um eficiente abrandamento da água, a qual passou a apresentar uma dureza, proveniente de íons carbonato próxima a zero.
Abstract: This work aimed to optimize the analytical methodology slowdown by ion exchange chromatography of water from the well named, for convenience, as "Well 1", conducting a study through the evaluation of physicochemical properties of the sample (pH, conductivity and hardness) and the performance of the regeneration of the resin filling the chromatographic column, in its treatment. For pH measurements, we used a digital potentiometer, pH METER MODEL and the conductance was analyzed by a digital conductivity Mca 150. In determining the total hardness of the sample, we used the volumetric complexation with EDTA solution and complexometric titration. Before passing through the ion exchange resin, the results obtained for the measurement of pH (5.56), indicating a considerable acidity of the samples, indicates non-compliance with the standards established by CONAMA Resolution 357/2005 (NATIONAL COUNCIL THE ENVIRONMENT), which states that water intended for human consumption and supply, should have pH in the range 6.0 to 9.0. The conductivity of the sample was 181.85 mS. In relation to the hardness, the sample is classified as a sample of medium hardness, with 70, 063 mg CaCO3 / L. After passing through the ion exchange resin, regenerated with alkaline solution, the pH of the sample has an alkaline character, accompanied by a decrease in conductivity and an effective slowing down of water, which began to show a hardness, carbonate ions from close to zero.
???metadata.dc.description.resumen???: El objetivo principal de este trabajo fue optimizar la metodología analítica en la desaceleración por cromatografía de intercambio iónico de agua de pozo, identificada, por conveniencia, como “Poço 1”, realizando un estudio a través de la evaluación de las propiedades fisicoquímicas de los muestra (pH, conductividad y dureza) y el rendimiento de la regeneración de resina, llenado de la columna cromatográfica, en su tratamiento. Para mediciones de pH, un potenciómetro digital, MODELO pH METER y se analizó la conductancia mediante un Medidor de conductividad digital Mca 150. Para determinar la dureza total de la muestra, el Volumetría de Complejización, con solución de EDTA como titulador Complexométrico. Antes pasando por la resina de intercambio iónico, los resultados obtenidos para las medidas de pH (5.56), que indicaron una acidez considerable de la muestra, apuntaron al incumplimiento de los estándares establecidos por la resolución CONAMA 357/2005 (CONSEJO NACIONAL DE MEDIO AMBIENTE), que determina que el agua destinada al abastecimiento y consumo humano, debe tener un pH en el rango de 6.0 a 9.0. La conductividad de la muestra fue de 181,85 EM. En cuanto a la dureza, la muestra se clasifica como muestra de dureza media, con 70.063 mg de CaCO3/L. Después de pasar por la resina de intercambio iónico, regenerada con solución alcalina, el pH de la muestra presenta un carácter alcalino, acompañado de una disminución de la conductividad y una eficiente ralentización de la agua, que comenzó a presentar una dureza, proveniente de iones de carbonato cercana a cero.
Keywords: Água de abastecimento
PH
Condutividade
Abrandamento
Resina de troca-iônica
Water supply
Conductivity
Relaxation
Ion-exchange resin
Suministro de agua
Conductividad
Relajación
???metadata.dc.subject.cnpq???: Química
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11343
Appears in Collections:Curso de Licenciatura em Química - CES - Monografias

Files in This Item:
File Description SizeFormat 
CLARISSA DAYANNE MEDEIROS DA FONSECA - TCC LICENCIATURA EM QUÍMICA CES 2011.pdfClarissa Dayanne Medeiros da Fonseca - TCC Licenciatura em Química CES 2011843.09 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.