Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1158
Full metadata record
DC FieldValueLanguage
dc.creator.IDSILVEIRA, G. F.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6432823876950364pt_BR
dc.contributor.advisor1NEVES, Gelmires de Araújo.-
dc.contributor.advisor1IDNEVES, G. A.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3167458244674160pt_BR
dc.contributor.advisor2FOOK, Marcus Vinicius Lia.-
dc.contributor.advisor2IDFOOK, M. V. L.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/4149843752530120pt_BR
dc.contributor.referee1LIMA, Verônica Evangelista de.-
dc.contributor.referee2PINTO, Maria Roberta de Oliveira.-
dc.description.resumoNa odontologia os implantes dentários osseointegráveis têm sido a melhor opção para o tratamento da perda dental. Estes permitem a recuperação estética e funcional, como a capacidade de mastigação. Atualmente vem se introduzindo a utilização de polímeros para fabricação de implantes osseointegráveis em substituição aos convencionais de titânio, a exemplo do poli-éter-éter-cetona (PEEK). Dessa forma, o objetivo deste trabalho é avaliar as propriedades do PEEK para aplicações odontológicas a partir das caracterizações morfológica, química e físicas, na perspectiva de uso como implante. As amostras foram analisadas através de Microscopia Eletrônica de Varredura – MEV com Espectroscopia por Energia Dispersiva de raios X – EDS, Difração de raios-X (DRX), Espectroscopia na Região de Infravermelho com Transformada de Fourier (FTIR), Calorimetria Exploratória Diferencial (DSC) e Molhabilidade por Ângulo de Contato. O resultado de MEV apresentou característica de um material de superfície lisa e densa. O EDS exibiu os elementos químicos oxigênio e carbono, característicos do polímero. No DRX observou-se que o PEEK tem comportamento de material semicristalino. Os espectros de FTIR revelaram as bandas típicas de absorção do PEEK. Na análise térmica realizada por calorimetria exploratória diferencial do PEEK, observou-se a presença de um pico endotérmico em 344,68° C, com início em aproximadamente 320° C e final em 349° C. De acordo com os resultados, verifica-se que o PEEK apresenta medidas de ângulo de contato menor que 90°, indicando hidrofilicidade. No ensaio mecânico, percebeu-se que tanto o módulo elástico quanto a resistência à tração do PEEK é mais próximo ao osso que o titânio. Conclui-se que o PEEK apresenta propriedades compatíveis para ser utilizado como biomaterialpt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM CIÊNCIA E ENGENHARIA DE MATERIAISpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia de Materiaispt_BR
dc.titleAvaliação das propriedades do PEEK para aplicações odontológicas.pt_BR
dc.date.issued2015-08-31-
dc.description.abstractIn odontology, the dental osseointegrated implants have been the best option for the treatment of total dental loss. These allow a functional and esthetical recovery, such as the ability of chewing. Nowadays, the use of polymers to fabricate osseointegrated implants has been introduced in replacement to the titanium’s conventionals, as for example the polyether ether ketone (PEEK). Therefore, the purpose of this work is to evaluate the properties of polyether ether ketone (PEEK) to use in dental applications, describing it physically, chemically and morphologically, in the use perspective as implant. The samples have been analyzed through a Scanning Transmission Electron Microscope (STEM), Energy Dispersive x-ray Spectroscopy (EDS), X-ray Diffraction, (XRD), Fourier Transform Infrared (FTIR), Differential Scanning Calorimeter (DSC), Wettability by contact Angle. The result of the STEM showed a characteristic of a flat and dense surface material. The EDS displayed the chemical elements oxygen and carbon, typical of a polymer. On the XRD, the PEEK was observed to behave as a semi crystalline material. The spectrums of the FTIR revealed typical bands of PEEK’s absortion. On the thermical analysis by PEEK’s differential scanning calorimeter, it was observed the presence of an endothermic peak in 344,68˚C, initiating approximately with 320˚C and ending in 349˚ C. According to the results, it is verified that the PEEK presents measures of contact angle less that 90˚, indicating hydrophilicity. On the mechanic test, it was perceived that the elastic module and PEEK’s traction resistence is the closest to the bone rather than the titanium. The conclusion therefore is that the PEEK shows compatible properties to be used as a biomaterial.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1158-
dc.date.accessioned2018-07-12T11:42:41Z-
dc.date.available2018-07-12-
dc.date.available2018-07-12T11:42:41Z-
dc.typeDissertaçãopt_BR
dc.subjectImplantes Dentáriospt_BR
dc.subjectOssointegraçãopt_BR
dc.subjectBiomaterialpt_BR
dc.subjectPEEKpt_BR
dc.subjectDental Implantspt_BR
dc.subjectOsseointegrationpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorSILVEIRA, Geiza Ferreira da.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.identifier.citationSILVEIRA, G. F. da. Avaliação das propriedades do PEEK para aplicações odontológicas. 2015. 55 f. Dissertação (Mestrado em Ciência e Engenharia de Materiais) – Programa de Pós-Graduação em Ciência e Engenharia de Materiais, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1158pt_BR
Appears in Collections:Mestrado em Ciência e Engenharia de Materiais.

Files in This Item:
File Description SizeFormat 
GEIZA FERREIRA DA SILVEIRA - DISSERTAÇÃO PPG-CEMat CCT 2015.pdfGeiza Ferreira da Silveira - Dissertação PPG-CEMat CCT 20151.29 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.