dc.description.resumo | Neste trabalho estuda-se o comportamento tensão-deformação de um deposito de areia compacta a muito compacta, de origem eólica, com base em resultados de ensaios realizados com o Pressiômetro Menard. A pesquisa foi desenvolvida nas dunas da praia da Taíba, no estado do Ceará, através de uma parceria entre as áreas de Geotecnia da UFCG, COPPE/UFRJ e UNIFOR, e teve como objetivo principal previsões de capacidade de carga de fundações superficiais como base em ensaios pressiométricos. No local estão instalados dez aparelhos aerogeradores de energia apoiados sobre sapatas quadradas. Os resultados obtidos a partir do pressiômetro Menard foram comparados com previsões de capacidade de carga e recalques baseadas em dados de sondagens com SPT disponíveis para o local. As comparações efetuadas mostraram que a tensão admissível prevista com base no pressiômetro foi aproximadamente 20% inferior a previsão feita com base no SPT, empregando-se um método tradicional brasileiro. Com relação aos métodos de outros países baseados no SPT, as comparações indicaram que a previsão baseada no ensaio pressiométrico foi 68% e 94% inferior aos valores previstos pelos métodos de Terzaghi & Peck (1967) e Parry (1978), respectivamente, e superou em 44% o valor obtido com a aplicação do método proposto por Meyerhof (1965). Dessa forma, sugere-se a complementação dos estudos com a realização de provas de carga sobre placa para a determinação do valor da tensão admissível do terreno. | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Centro de Tecnologia e Recursos Naturais - CTRN | pt_BR |
dc.publisher.program | PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL | pt_BR |
dc.publisher.initials | UFCG | pt_BR |
dc.subject.cnpq | Engenharia Civil | - |
dc.title | Previsão da capacidade de carga de fundações superficiais em solos de dunas, através do pressiômetro Ménard. | pt_BR |
dc.date.issued | 2004-03-26 | - |
dc.description.abstract | In the present work, the stress-deformation behavior of an Aeolian sand deposit of a compact to highly compact type is studied based on the results of field test conducted by using the Menard pressure meter. The research was carried out in a partnership among UFCG, COPPE/UFRJ, and UNIFOR, at Taiba beach, Ceara State, Brazil, where ten Aeolian energy generator is installed on squared foundations, and had as the main objective, to forecast the bearing capacity of superficial foundations through pressure meter tests. The results from the Menard pressure meter testing were compared with those obtained in borings done at the same site, based on a SPT standard, and revealed that the accepted stress provided by the Menard pressure meter was about 20% lower than the one obtained with SPT standard, when a traditional Brazilian method was applied. Regarding to SPT methods from other countries, the comparisons indicated that forecast based on the Menard tests were 68% and 94% lower than those methods stated by Terzaghi and Peck (1967) and Perry (1978), respectively. On the other hand, the results from Menard pressure meter were 44% higher than those obtained through the application of the method proposed by Meyerhof (1965). Based on these results, it is suggested that additional studies should be done, considering the accomplishment of bearing test on plates to determine the terrain acceptable stress. | pt_BR |
dc.identifier.uri | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11818 | - |
dc.date.accessioned | 2020-02-12T12:22:31Z | - |
dc.date.available | 2020-02-12 | - |
dc.date.available | 2020-02-12T12:22:31Z | - |
dc.date.available | Fundações Superficiais. | - |
dc.type | Dissertação | pt_BR |
dc.subject | Pressiômetros | - |
dc.subject | Pressiômetro Ménard | - |
dc.subject | Capacidade de Carga | - |
dc.subject | Recalques | - |
dc.subject | Sondagens com SPT | - |
dc.subject | Tensão | - |
dc.subject | Ensaio Pressiométrico | - |
dc.subject | Geotecnia | - |
dc.subject | Pressiometers | - |
dc.subject | Ménard Pressiometer | - |
dc.subject | Battery Capacity | - |
dc.subject | Settlements | - |
dc.subject | SPT Polls | - |
dc.subject | Tension | - |
dc.subject | Pressiometric Assay | - |
dc.subject | Geotechnics | - |
dc.rights | Acesso Aberto | pt_BR |
dc.creator | LOPES, Simone Ribeiro. | - |
dc.publisher | Universidade Federal de Campina Grande | pt_BR |
dc.language | por | pt_BR |
dc.title.alternative | Forecasting the load capacity of surface foundations in dune soils, using the menard pressiometer. | pt_BR |
dc.identifier.citation | LOPES, Simone Ribeiro. Previsão da capacidade de carga de fundações superficiais em solos de dunas, através do pressiômetro Ménard. 2004. 150f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Programa de Pós-Graduação em Engenharia Civil e Ambiental, Universidade Federal de Campina Grande - Paraíba - Brasil, 2004. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11818 | pt_BR |
Appears in Collections: | Mestrado em Engenharia Civil e Ambiental. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
SIMONE RIBEIRO LOPES - DISSERTAÇÃO PPGECA 2004.pdf | Simone Ribeiro Lopes - Dissertação PPGECA 2004. | 12.55 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.