Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11936
Full metadata record
DC FieldValueLanguage
dc.creator.IDDINIZ, R. C. S.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/7915381755425396pt_BR
dc.contributor.advisor1FREIRE, Raimundo Carlos Silvério.-
dc.contributor.advisor1MELO, Hiran de.-
dc.contributor.advisor1IDFREIRE, R. C. S.pt_BR
dc.contributor.advisor1IDMELO, H.-
dc.contributor.advisor1IDMELO, H.-
dc.contributor.advisor1IDMELO, H.-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4016576596215504pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2127559774805521-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2127559774805521-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2127559774805521-
dc.contributor.referee1FERREIRA, Rômulo Pires Coelho.-
dc.contributor.referee2SILVA, Antonio Almeida da.-
dc.contributor.referee3CATUNDA, Sebastian Yuri Cavalcanti.-
dc.description.resumoOs anemômetros baseados no principio de medição da velocidade do fluido a partir da transferência de calor, que usam sensores termo-resistivos aquecidos eletricamente, são chamados de "Anemômetros a Fio Quente". Eles podem ser classificados como instrumento elétrico de medição, pois o tipo de sensor utilizado modifica um parâmetro elétrico, grandeza que o instrumento ira processar, em função da grandeza que se deseja medir. No sentido de determinar a velocidade do fluido a partir de um parâmetro elétrico, utiliza-se o principio da equivalência elétrica nas arquiteturas de medição, dentre as estruturas existentes, investigou-se a estrutura a temperatura do sensor constante, conhecida pela sigla "CTA", do inglês "Constant Temperature Anemometer". Neste trabalho apresentam-se considerações de projeto para implementação de CTA com realimentação PWM, além de procedimentos para caracterização de sensores, circuitos para compensação de temperatura do fluido e um sistema de aquisição de dados. Baseado nas considerações de projeto apresentadas neste trabalho, implementou-se um CTA com excitação PWM que mede a velocidade do ar.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleConsiderações de projeto para anemômetros a fio quente baseado em estruturas realimentadas.pt_BR
dc.date.issued2003-12-18-
dc.description.abstractAnemometers based on the measurement principle of the fluid velocity using heat transfer and heated electrically thermo-resistive sensor are called Hot wire anemometer. They can be classified as an measurement electrical instrument because the sensor used has one of its electrical parameter modified in presence of the fluid velocity variation. In order to obtain a fluid velocity from a electric parameter one use the electrical equivalence principle in the measurement structures. Among measurement structures that use such a principle, it was investigated the called Constant Temperature Anemometer - CTA. This dissertation consists of establishing a methodology to be used in design of fluid velocity measurement systems based on feedback structures using PWM excitation, beyond procedures for sensor characterization, circuits of fluid temperature compensation and a data acquisition system. Based on the methodology presented in this dissertation, it was developed a CTA with PWM excitation which measures air velocity.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11936-
dc.date.accessioned2020-02-14T15:20:28Z-
dc.date.available2020-02-14-
dc.date.available2020-02-14T15:20:28Z-
dc.typeDissertaçãopt_BR
dc.subjectAnemômetro-
dc.subjectSensores Termorresistivos-
dc.subjectAnemômetros a Fio Quente-
dc.subjectEquivalência Elétrica-
dc.subjectPonte de Wheatstone-
dc.subjectPrincípio de Medição da Velocidade do Fluido-
dc.subjectAnemometer-
dc.subjectThermoresistive Sensors-
dc.subjectHot Wire Anemometers-
dc.subjectElectrical Equivalence-
dc.subjectWheatstone Bridge-
dc.subjectFluid Speed Measurement Principle-
dc.rightsAcesso Abertopt_BR
dc.creatorDINIZ, Ronny Clay Santos.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeDesign considerations for hot wire anemometers based on feedback structures.pt_BR
dc.identifier.citationDINIZ, Ronny Clay Santos. Considerações de projeto para anemômetros a fio quente baseado em estruturas realimentadas. 112f. (Dissertação) Mestrado em Engenharia Elétrica, Curso de Pós-Graduação em Engenharia Elétrica, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - Paraíba - Brasil, 2004.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
RONNY CLAY SANTOS DINIZ - DISSERTAÇÃO PPGEE 2004.pdfRonny Clay Santos Santos Diniz - Dissertação PPGEE 200416.47 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.