Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1451
Full metadata record
DC FieldValueLanguage
dc.creator.IDFERREIRA, R. R.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/9103954192801091pt_BR
dc.contributor.advisor1SOUZA, Enio Pereira de.-
dc.contributor.advisor1IDSOUZA, E. P.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/7752212981363912pt_BR
dc.contributor.referee1BRITO, José Ivaldo Barbosa de.-
dc.contributor.referee2MENDES, David.-
dc.description.resumoOs balanços de calor e umidade são comumente utilizados no estudo do comportamento atmosférico na presença de forçamento térmicos e dinâmicos. Em 1973, alguns autores introduziram um método para o cálculo do que chamaram de fonte aparente de calor (Q1) e sumidouro aparente de umidade (Q2), obtidos como resíduos dos balanços de calor e umidade em grande escala. Com este trabalho pretende-se investigar as características dos balanços de umidade e calor para a região de atuação de um vórtice ciclônico de altos níveis (VCAN) sobre a região nordeste do Brasil (NEB), para um evento ocorrido durante o período de 13 a 24 de janeiro de 2011. A análise do ciclo de vida relacionada ao VCAN em termos do balanço de umidade e calor configura-se de grande relevância, já que as mudanças de fase da água são importantes fontes ou sumidouros de energia na atmosfera tropical, em que a condensação da grande quantidade de vapor d’água leva à liberação de grande quantidade de energia, na forma de calor latente de condensação. Os conjuntos de dados utilizados neste estudo foram de reanálises do ERA-Interim pertencentes ao European Centre for Medium-Range Weather Forecasts (ECMWF) com uma resolução espacial de 0.5ᵒx0.5ᵒ, juntamente com o uso de imagens de satélite GOES-12 do canal infravermelho realçado pertencente ao banco de imagens da Divisão de Satélites Ambientais (DSA/INPE), informações de radiossondagem atmosféricas, dados de precipitação estimada pelo satélite Tropical Rainfall Measuring Mission (TRMM), e ainda dados de estação meteorológica de superfície do Instituto Nacional de Meteorologia (INMET). A justificativa que resultou na escolha deste caso de VCAN levou em consideração o fato deste evento ter sido bastante intenso durante seu tempo vida, e teve características bem significantes nas áreas em que o seu centro e sua periferia atuaram. Foram definidos pontos de análises de Q1 e Q2, esses pontos foram ditos como regiões onde o centro e a borda do vórtice estiveram atuando durante seu ciclo de vida. Como resultado foi observado que sobre o ponto da borda, houve uma evolução temporal de Q1 e Q2 desde o nível de 1000 até 200 hPa, durante o período de atuação do vórtice sobre Bom Jesus da Lapa, esses parâmetros mostraram que devido ao centro do VCAN atuar com mais intensidade sobre o local, a subsidência foi dominante, principalmente nos dias em que esse sistema esteve mais intenso. Os picos de Q1 por volta de 400 hPa são indicativos de que o ar frio que advém do centro do VCAN, pode inibir o processo de convecção, e os picos de Q2 por volta de 700 hPa podem estar associados a uma convecção rasa. Já para a cidade de Natal foi visto que durante a atuação da borda do VCAN, Q1 e Q2 se mostraram bem correlacionados, sendo isto um indicativo que o processo de formação de convecção profunda e a liberação de calor latente estiveram acontecendo.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM LETRAS EM REDE PROFLETRAS (UFRN)pt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqMeteorologiapt_BR
dc.titleAspectos termodinâmicos de um vórtice ciclônico de altos níveis sobre o Nordeste do Brasil.pt_BR
dc.date.issued2017-02-24-
dc.description.abstractA Heat and moisture balance are commonly used in the study of atmospheric behavior in the presence of thermal and dynamic forcing. In 1973, some authors introduced a method for calculating what they called apparent heat source (Q1) and apparent moisture sink (Q2), obtained as a residual of large-scale heat and moisture balance. This work intends to investigate the characteristics of moisture and heat balance for the performance of a cyclonic vortex of upper levels (VCAN) in northeastern Brazil (NEB) that occurred during the period from 13 to 24 January 2011. The life cycle analysis of VCAN in terms of moisture and heat balance is of major importance, since the phase changes of water are important sources or sinks of energy for the tropical atmosphere, in which large amounts of condensation water vapour leads to release of large amount of energy, in the form of latent heat of condensation. The data set used in this study are of the ERA-Interim reanalysis of the European Centre for MediumRange Weather Forecasts (ECMWF) with a spatial resolution of 0.5°, along with the use of GOES-12 infrared-channel satellite imagery from the Division of Environmental Satellites (DSA/INPE), atmospheric apparatus information, estimated precipitation data the satellite Rainfall Tropical Measuring Mission (TRMM) , and weather station data of the surface of the National Institute of meteorology (INMET). The justification that resulted in the choice of this case VCAN took into account the fact this event was very intense during his time, life and it had very significant characteristics in the areas in which the center and its periphery acted. Points were defined analyses of Q1 and Q2, these points were defined as regions where the center and the edges of the vortex were acting during their life cycle. As a result it was observed that at the border point, there was a temporal evolution of Q1 and Q2 since the 1000 level up to 200 hPa, during the period of operation of the vortex at Bom Jesus da Lapa these parameters showed that due to the center of the VCAN act with more intensity about this site, the subsidence was dominant, especially in the days when this system was more intense, the negative peaks of Q1 around 400 hPa are indicative that the cold air comes from the center of the VCAN may inhibit the process of convection, and the peaks of Q2 around 700 hPa can be associated with shallow convection. For the city of Natal it was seen during the performance of the VCAN, Q1 and Q2 were well correlated, being this an indication that the process of formation of deep convection and the latent heat release were occuring.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1451-
dc.date.accessioned2018-08-14T20:28:08Z-
dc.date.available2018-08-14-
dc.date.available2018-08-14T20:28:08Z-
dc.typeDissertaçãopt_BR
dc.subjectVórtice Ciclônico de Altos Níveis (VCAN)pt_BR
dc.subjectComportamento Atmosférico - Forçamento Térmicos e Dinâmicospt_BR
dc.subjectBalanços de Umidade e Calor - Nordeste do Brasilpt_BR
dc.subjectHumiditypt_BR
dc.subjectNortheastern Brazilpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorFERREIRA, Rosaria Rodrigues.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.description.sponsorshipCapespt_BR
dc.identifier.citationFERREIRA, R. R. Aspectos termodinâmicos de um vórtice ciclônico de altos níveis sobre o Nordeste do Brasil. 2017. 71 f. Dissertação (Mestrado em Meteorologia) – Programa de Pós-Graduação em Meteorologia, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande, Paraíba, Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1451pt_BR
Appears in Collections:Mestrado em Meteorologia.

Files in This Item:
File Description SizeFormat 
ROSARIA RODRIGUES FERREIRA – DISSERTAÇÃO (PPGMET) 2017.pdfRosaria Rodrigues Ferreira - Dissertação PPGMet CTRN 20173.82 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.