Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1478
Full metadata record
DC FieldValueLanguage
dc.creator.IDMEDEIROS, M. R.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/5921612583032386pt_BR
dc.contributor.advisor1FRANÇA, Kepler Borges.-
dc.contributor.advisor1IDFRANÇA, K. B.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3620576114544758pt_BR
dc.contributor.advisor-co1PEARSON, Howard William.-
dc.contributor.advisor-co1IDPEARSON, H. W.pt_BR
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/9063947672998261pt_BR
dc.contributor.referee1FARIAS NETO, Severino Rodrigues de.-
dc.contributor.referee2LABORDE, Hervé Michel.-
dc.contributor.referee3PEARSON, Howard William.-
dc.contributor.referee4VIEIRA, Fernando Fernandes.-
dc.description.resumoA inativação de bactérias patogênicas é um requisito fundamental no tratamento de água potável. Os avanços na pesquisa de tratamento de água têm sido direcionados para a aplicação de tecnologias que usam menos reagentes químicos, reduzindo assim a formação de subprodutos tóxicos e reduzindo o tempo de operação. Para tanto, objetivou-se projetar e avaliar a eficiência de um reator eletrolítico de bancada, composto pelo par de eletrodos: esponja de níquel (ânodo) e fibra de carbono (cátodo), operando de forma contínua, na desinfecção da bactéria indicadora Escherichia coli (E. coli). Inicialmente, os ensaios foram realizados com água de abastecimento público do LABDES/UFCG, contaminada em laboratório com uma concentração constante, avaliando os efeitos da aplicação das diferenças de potenciais (ddp) de 3,0 V, 5,0 V, 7,0 V e 9,0 V nos respectivos tempos médios de residência (tm): 46,8 s, 65,4 s, 82,2 s e 121,8 s, estimados experimentalmente através do método de injeção de uma solução traçadora (NaCl), nas vazões de 0,5, 1,0, 1,5 e 2,0 L.min-1, respectivamente, nos parâmetros físico-químicos e na desinfecção de E. coli dessa água. Posteriormente, foi proposto o estudo do desempenho do reator em relação aos mesmos parâmetros (condutividade elétrica, pH, turbidez e cor), acrescentando a análise de concentração de cloreto (Cl-). Nessa etapa, foram consideradas maiores faixas de ddp e um tempo médio de residência constante (121,8s), e avaliando diferentes tipos de águas (deionizada, solução de NaCl, água de abastecimento público de Campina Grande) sem e com contaminação de E. coli. Os resultados obtidos, em termos de percentuais de desinfecção de E. coli na água do LABDES, mostraram que sob as ddp de 5,0 e 7,0 V, esses percentuais foram de 99,84 e 99,40%, respectivamente para o maior tempo de residência (121,8 s). Nos experimentos realizados com as outras águas, chegou-se a 100% de desinfecção de E. coli na solução de NaCl contaminada com 103UFC.mL-1, nas densidades de corrente de 9,4 e 11,89 mA.cm-2, respectivamente, e na água de abastecimento público de Campina Grande nessa mesma ordem de concentração de bactéria, a desinfecção se mostrou 100% eficaz nas densidades de corrente de 9,92, 11,1 e 11,7 mA.cm-2. Os resultados mostram que a proposta do trabalho em remover grande parte ou 100% de E. coli de águas, principalmente as águas de consumo humano, foi alcançada.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia químicapt_BR
dc.titleDesenvolvimento e caracterização de um reator eletrolítico para desinfecção de águas contaminadas com Escherichia coli.pt_BR
dc.date.issued2018-04-10-
dc.description.abstractInactivation of pathogenic bacteria is a fundamental requirement in the treatment of drinking water. Advances in water treatment research have been directed toward the application of technologies that use fewer chemical reagents, thereby reducing the formation of toxic byproducts and reducing the time of operation. The objective of this study was to design and evaluate the efficiency of an electrolytic bench reactor composed of the electrode pair: nickel sponge (anode) and carbon fiber (cathode), continuously operating in the disinfection of the indicator bacterium Escherichia coli (E. coli). Initially, the tests were carried out with LABDES / UFCG public contaminated water in a laboratory with a constant concentration, evaluating the effects of applying the potential differences (ddp) of 3.0 V, 5.0 V, 7.0 V and 9,0 V in the respective average residence times (tm): 46.8 s, 65.4 s, 82.2 s and 121.8 s, estimated experimentally by the method of injection of a tracer solution (NaCl) at the flow rates of 0.5, 1.0, 1.5 and 2.0 L.min-1, respectively, in the physico-chemical parameters and in the disinfection of E. coli from this water. Subsequently, it was proposed to study the performance of the reactor in relation to the same parameters (electrical conductivity, pH, turbidity and color), adding the analysis of chloride concentration (Cl-). In this step, we considered greater ranges of ddp and a mean constant residence time (121.8s), and evaluating different types of water (deionized, NaCl solution, public supply water of Campina Grande) without and with E. contamination. coli. The results obtained, in terms of percentages of disinfection of E. coli in LABDES water, showed that under the ddp of 5.0 and 7.0 V, these percentages were 99.84 and 99.40%, respectively, for the highest time of residence (121.8 s). In the experiments performed with the other waters, 100% disinfection of E. coli was achieved in NaCl solution contaminated with 103 CFU.mL -1, at current densities of 9.4 and 11.89 mA.cm-2, respectively, and in the public supply water of Campina Grande in the same order of concentration of bacteria, disinfection was 100% efficient at current densities of 9.92, 11.1 and 11.7 mA.cm-2. The results show that the proposal of the work to remove much or 100% of E. coli from waters, mainly waters of human consumption, was reached.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1478-
dc.date.accessioned2018-08-16T17:40:05Z-
dc.date.available2018-08-16-
dc.date.available2018-08-16T17:40:05Z-
dc.typeTesept_BR
dc.subjectReator Eletrolíticopt_BR
dc.subjectEscherichia Colipt_BR
dc.subjectCampo Elétricopt_BR
dc.subjectDesinfecção da Águapt_BR
dc.subjectElectrolytic Reactorpt_BR
dc.subjectElectric Fieldpt_BR
dc.subjectDisinfection of Waterpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorMEDEIROS, Mariana Rodrigues de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeDevelopment and characterization of an electrolytic reactor for disinfection of water contaminated with escherichia coli.pt_BR
dc.description.sponsorshipCapespt_BR
dc.identifier.citationMEDEIROS, M. R. de. Desenvolvimento e caracterização de um reator eletrolítico para desinfecção de águas contaminadas com Escherichia coli. 2018. 121f. Tese (Doutorado em Engenharia Química) – Programa de Pós-Graduação em Engenharia Química, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2018. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1478pt_BR
Appears in Collections:Doutorado em Engenharia Química.

Files in This Item:
File Description SizeFormat 
MARIANA RODRIGUES DE MEDEIROS - TESE PPGEQ 2018.pdfMariana Rodrigues de Medeiros - Tese PPGEQ 20181.51 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.