Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/17406
Full metadata record
DC FieldValueLanguage
dc.creator.IDMACÊDO, E. C. T.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/1567664152355721pt_BR
dc.contributor.advisor1LIRA, José Gutembergue de Assis.
dc.contributor.advisor1IDLIRA, J. G. A.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9422522354709015pt_BR
dc.contributor.referee1FREIRE, Raimundo Carlos Silvério.
dc.description.resumoOs pára-raios a base de ZnO são equipamentos utilizados na proteção contra sobretensões atmosféricas e de manobra em subestações e linhas de transmissão. Eles são formados por varistores, elementos que apresentam alta não-linearidade entre a tensão e a corrente. Os pára-raios apresentam degradação com o tempo, seja com a própria tensão da rede ou por sobretenões. O monitoramento contínuo da intensidade da corrente de fuga pode indicar falhas permanentes ou atuações momentâneas do pára-raios, enquanto que a análise de suas componentes harmônicas indica o grau de degradação do equipamento ou algumas falhas. A medição e análise harmônica da corrente de fuga têm sido usadas no diagnóstico do estado de degradação dos pára-raios de óxido de zinco (ZnO). Para o desenvolvimento deste trabalho, partiu-se de um estudo bibliográfico sobre os pára-raios de ZnO, desde sua construção física até o seu comportamento em operação no sistema elétrico de potência. Baseados na literatura existente a cerca do tema proposto, desenvolveu-se protótipos dos circuitos necessários para se realizar o monitoramento continuo da corrente de fuga que circula no pára-raios, ou seja, foram desenvolvidos circuitos de um condicionador de sinais, sensor de corrente, analisador de espectro. O circuito condicionador de sinais é destinado a realizar a adequação dos níveis de tensão e corrente a serem processados, o circuito sensor de corrente é o responsável por fornecer em sua saída uma tensão proporcional a corrente de fuga que circula no páraraios e por fim, temos o analisador de espectro que realiza todas as operações matemáticas e analise harmônica dos sinais de tensão e corrente obtidos a partir do páraraios. Por fim, apresentam-se os resultados obtidos nas simulações e nas montagens experimentais, sugerindo algumas sugestões para futuros trabalhos.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleMedidor de corrente de fuga baseado em microcontrolador aplicado a pára-raios de óxido de zinco.pt_BR
dc.date.issued2009-02
dc.description.abstractSurge arresters are equipments of greater importance for the power electrical systems protection. Their task is avoiding switching and atmospheric surges to reach equipments like power transformers. A failure in a surge arrester result in the exposure of the electrical system equipments to electrical surges leading to a complete turn off of the system or even the surge arrester explosion. To avoid this problem, the maintenance of these equipments is made by means of regular monitoring. Measurement of the resistive leakage current and analysis of its harmonic components is one of the most used techniques to evaluate the degradation level of metal oxide surge arresters. This measurement requires the samples acquisition of the voltage applied on the arrester and its leakage current samples what is not a simple task to achieve when the arrester is operating on field. This text presents a new device based on microcontroller PIC® to provide the measurement of the harmonic components of the resistive leakage current in a surge arrester. As main characteristics, this device presents a low cost and simplicity to be set on field equipments.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/17406
dc.date.accessioned2021-02-26T17:27:10Z
dc.date.available2021-02-26
dc.date.available2021-02-26T17:27:10Z
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.subjectMedidor de corrente de fugapt_BR
dc.subjectMicrocontroladorpt_BR
dc.subjectPára-raios de óxido de zincopt_BR
dc.subjectSensor de corrente de figapt_BR
dc.subjectCondicionamento de sinaispt_BR
dc.subjectAlgoritmo de Goertzelpt_BR
dc.subjectDigitalização de sinal analógicopt_BR
dc.subjectPára-raios à base de ZnOpt_BR
dc.subjectAnálise harmônica da corrente de fugapt_BR
dc.subjectLeakage current meterpt_BR
dc.subjectMicrocontrollerpt_BR
dc.subjectZinc oxide surge arresterspt_BR
dc.subjectFig current sensorpt_BR
dc.subjectSignal conditioningpt_BR
dc.subjectGoertzel algorithmpt_BR
dc.subjectAnalog signal scanningpt_BR
dc.subjectZnO-based surge arresterpt_BR
dc.subjectLeakage current harmonic analysispt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorMACÊDO, Euler Cássio Tavares de.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeLeakage current meter based on microcontroller applied to zinc oxide surge arresters.pt_BR
dc.identifier.citationMACÊDO, Euler Cássio Tavares de. Medidor de corrente de fuga baseado em microcontrolador aplicado a pára-raios de óxido de zinco. 2009. f51. Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2009. Disponível em:http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/17406pt_BR
Appears in Collections:Curso de Bacharelado em Engenharia Elétrica - CEEI - Monografias

Files in This Item:
File Description SizeFormat 
EULER CÁSSIO TAVARES DE MACÊDO - TCC ENG. ELÉTRICA 2009.pdfEuler Cássio Tavares de Macêdo - TCC Engenharia Elétrica 2009.3.53 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.