Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/17541
Full metadata record
DC FieldValueLanguage
dc.creator.IDFREITAS, D. A.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/7527929004903142pt_BR
dc.contributor.advisor1CORRÊA, Maurício Beltrão de Rossiter.
dc.contributor.advisor1IDCORRÊA, M. B. R.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0041843905239864pt_BR
dc.description.resumoO presente trabalho aborda uma problemática bastante discutida na área do petró- leo nos dias de hoje. O controle e acionamento de bombas centrífugas submersas de alta potência é bastante complexo e nos dias atuais existem poucos especialistas pesquisando na área. Esse foi o grande incentivo da escolha do tema. O trabalho consiste em verifi- car os efeitos causados no sinal de tensão alternada gerado por um inversor no terminal de um motor quando o mesmo percorre um alimentador muito longo. No início temos uma abordagem básica sobre inversores e suas topologias assim como algumas técnicas utilizadas para realizar o chaveamento dos mesmos. Discutimos alguns problemas em se utilizar um inversor mais simples de três níveis e quais são as vantagens de se utilizar um inversor multinível no problema em questão. Logo em seguida discutimos sobre as distorções causadas pelos cabos longos. Temos o efeito pelicular que na verdade não é o grande agente dos resultados obtidos e em especial o efeito da re exão de ondas viajantes que representa boa parte da distorção do sinal transmitido. Em seguida, discutiremos um modelo matemático de um cabo longo para possibilitar a simulação do sistema. Como não há nenhum modelo nos dias de hoje para tal situação, é utilizada a teoria das linhas de transmissão que se assemelha bastante ao problema em questão. Por m, temos a simula- ção total do sistema utilizando a ferramenta simulink do matlab. O sistema consistem em um inversor trifásico PWM de nove níveis conectado ao modelo de cabo longo escolhido que se conecta a um motor de indução trifásico. Após a simulação, vários grá cos foram gerados para que possamos visualizar e analisar os resultados obtidos. Palavras-chaves: bombas centrífugas submersas, inversores, inversores multinível, PWM, efeito pelicular, re exão de ondas, cabo longo, motor de indução.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleVerificação do efeito de cabos longos no acionamento de motores elétricos.pt_BR
dc.date.issued2011
dc.description.abstractThis study addresses a widely debated issue in the oil eld nowadays. The control and drive of high power submersible centrifugal pumps is very complex and nowadays there are few experts researching in the area. That was the great incentive of choice of topic. The work is to verify the e ects on the alternating voltage signal generated by an inverter into the terminal of an engine when it goes a very long feeder. At the beginning we have a basic approach on inverters and their topologies as well as some techniques used to perform the switching of the same. We discuss some problems in using a simple inverter with three levels and what are the advantages of using a multilevel inverter in the problem at hand. Soon after we discussed the distortions caused by long cables. We have the skin e ect which actually is not the great agent of the results and in particular the e ect of re ection of traveling waves which represents much of the distortion of the transmitted signal. Then, we discuss a mathematical model of a long cable to allow the simulation of the system. As there is no model today for such a situation, we took part of the transmission lines theory that is very similar to the problem at hand. Finally, we have the full system simulation using matlab simulink tool. The system consists of a three-phase nine level PWM inverter connected to chosen long cable model that connects to a three-phase induction motor. After the simulation, several graphs were generated so that we can visualize and analyze the results. Keywords: submersible centrifugal pumps, inverters, multilevel inverters, PWM, skin e ect, wave re ection, long cable, induction motor.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/17541
dc.date.accessioned2021-03-08T17:21:51Z
dc.date.available2021-03-08
dc.date.available2021-03-08T17:21:51Z
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.subjectMotores elétricospt_BR
dc.subjectCabos longospt_BR
dc.subjectEfeito de cabos longospt_BR
dc.subjectBombas centrífugas submersaspt_BR
dc.subjectInversores multinívelpt_BR
dc.subjectMotor de induçãopt_BR
dc.subjectPWM senoidalpt_BR
dc.subjectTécnicas de chaveamentopt_BR
dc.subjectDistorções em sinais - cabospt_BR
dc.subjectElectric motorspt_BR
dc.subjectLong cablespt_BR
dc.subjectLong cable effectpt_BR
dc.subjectSubmerged centrifugal pumpspt_BR
dc.subjectMultilevel Inverterspt_BR
dc.subjectInduction motorpt_BR
dc.subjectSinusoidal PWMpt_BR
dc.subjectSwitching techniquespt_BR
dc.subjectSignal distortions - cablespt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorFREITAS, Daniel Araújo de.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeVerification of the effect of long cables on the activation of electric motors.pt_BR
dc.identifier.citationFREITAS, Daniel Araújo de. Verificação do efeito de cabos longos no acionamento de motores elétricos. 2011. f42. Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2011. Disponível em:http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/17541pt_BR
Appears in Collections:Curso de Bacharelado em Engenharia Elétrica - CEEI - Monografias

Files in This Item:
File Description SizeFormat 
DANIEL ARAÚJO DE FREITAS - TCC ENG. ELÉTRICA 2011_1.pdfDaniel Araújo de Freitas - TCC Engenharia Elétrica 2011.1.97 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.