Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18182
Full metadata record
DC FieldValueLanguage
dc.creator.IDLOUREIRO, F. C. C. L.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/3820070447502334pt_BR
dc.contributor.advisor1LIMA, Antonio Marcus Nogueira.
dc.contributor.advisor1IDLIMA, A. M. N.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2237395961717699pt_BR
dc.contributor.advisor2NEFF, Helmut.
dc.contributor.advisor2IDNEFF, H.pt_BR
dc.description.resumoA microfluídica aliada à optofluídica é um campo emergente com importantes aplicações em biotecnologia e química analítica e que precisa de um maior estudo para o desenvolvimento de dispositivos analíticos miniaturizados. Este trabalho tem como objetivo estudar sistemas microfluídicos, através de métodos experimentais, usando biossensores ópticos e, em especial, aqueles baseados na tecnologia de ressonância de plasmon de superfície (SPR). A tecnologia SPR permite a determinação dos parâmetros de transporte, bem como o monitoramento de interações moleculares. Neste estudo, foram utilizadas células microfluídicas (altura de 0, 75 e 1 mm e volume de 7 e 11 μl) na qual um sensor SPR é integrado. Esta integração permitiu a proposição de: 1) um método para avaliar quantitativamente os parâmetros de transporte, tais como a velocidade de escorregamento e coeficiente de difusão molecular e 2) um método para avaliar as constantes cinéticas e termodinâmicas de ligações de substâncias (biotina, proteínas globulares, soro humano) na superfície sensível do biossensor. Estes resultados permitem melhorar o projeto experimental de imunoensaios, em termos da escolha das substâncias mais adequadas para a camada de imobilização, do volume de analito, e do limiar de detecção, tendo em vista o desenvolvimento de um sistema para detecção de afinidade em reações antígeno-anticorpo, com ênfase especial na detecção do vírus da dengue (DENV).pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleUso de sensor óptico no estudo de sistemas microfluídicos com, e sem, adsorção biomolecular.pt_BR
dc.date.issued2015-01
dc.description.abstractThis work aims to studymicrofluidic systems, through experimentalmethods, using optical biosensors, more especially, surface plasmons resonance (SPR) technology based sensors. The microfluidic area and biotechnology advancement has enabled the development of microsystems that can potentially be used in public health to supply demands for portable and low cost diagnostic devices. However, microfluidic science still requires greater knowledge of fluid devices properties and performance, when reduced from macro to micro scales. Here a method is proposed for realtime monitoring of SPR surface changes as a novel and important tool of analysis for molecular interaction assays and system performance. On this study one microfluidic cell integrated with a SPR sensor is used. This proposed system enables reduction of samples diffusion time and volume allied with SPR sensor advantages of higher precision and sensitivity. The well defined detection range of refractive index changes, at the SPR sensor surface, guarantees high precision measurements. Here, we perform quantitative assessments of transport parameters, such as slip-flow and convective-diffusion flow velocity as a means to optimize system performance parameters. More specifically, we can evaluate qualitatively and quantitatively the kinetic and thermodynamic properties of biotin and proteins with great reliability. Preliminary immunoassays results allow further development of SPR immunosensors applications for affinity detection in antigen-antibody reactions, with special emphasis on dengue virus (DENV) detection and serotype identification.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18182
dc.date.accessioned2021-04-19T17:46:04Z
dc.date.available2021-04-19
dc.date.available2021-04-19T17:46:04Z
dc.typeTesept_BR
dc.subjectSistemas microfluídicospt_BR
dc.subjectAdsorção biomolecularpt_BR
dc.subjectSensor ópticopt_BR
dc.subjectBiossensorespt_BR
dc.subjectImunoensaiospt_BR
dc.subjectRessonância de plasmon de superfíciept_BR
dc.subjectOptofluídicapt_BR
dc.subjectMicrofluídicapt_BR
dc.subjectMicro-fluidodinâmicapt_BR
dc.subjectHidrodinâmica da difusividade molecularpt_BR
dc.subjectImunologia - princípiospt_BR
dc.subjectMicrofluidic systemspt_BR
dc.subjectBiomolecular adsorptionpt_BR
dc.subjectOptical sensorpt_BR
dc.subjectBiosensorspt_BR
dc.subjectImmunoassayspt_BR
dc.subjectSurface plasmon resonancept_BR
dc.subjectOptofluidicpt_BR
dc.subjectMicrofluidicspt_BR
dc.subjectMicro-fluid dynamicspt_BR
dc.subjectHydrodynamics of molecular diffusivitypt_BR
dc.subjectImmunology - principlespt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorLOUREIRO, Fernanda Cecilia Correia Lima.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeUse of an optical sensor in the study of microfluidic systems with, and without, biomolecular adsorption.pt_BR
dc.identifier.citationLOUREIRO, Fernanda Cecilia Correia Lima. Uso de sensor óptico no estudo de sistemas microfluídicos com, e sem, adsorção biomolecular. 2015. 183f. Tese (Doutorado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18182pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
FERNANDA CECILIA CORREIA LIMA LOUREIRO - TESE PPGEE 2015.pdfFernanda Cecilia Correia Lima TESE PPGEE 2015.5.32 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.