dc.description.resumoA redução da complexidade e custo dos conversores estáticos podem ser alcançados através do uso de topologias com número reduzido de dispositivos. Nesse sentido, é proposto neste trabalho o estudo de topologias de conversores que utilizam braços de dois e três-níveis (NPC -Neutral Point Clamped) em sua composição (topologias híbridas). Para a conversão de energia CC/CA ser˜ao avaliadas quatro configurações presentes na literatura. Para a conversão CA/CC/CA com cargas a três fios, duas topologias convencionais e cinco propostas. Para a conversão CC/CA utilizando cargas a quatro fios, duas topologias convencionais e quatro propostas. Para cada topologia apresentada, foram estudados os seguintes pontos: modelagem da configuração, estratégias PWM, estratégia de controle. Foram realizados estudos comparativos entre as topologias propostas e as convencionais, avaliando seus desempenhos, através dos parâmetros: Distorção harmônica das tensões, distorção harmônica das correntes, perdas nas chaves e tensão do barramento. Através das análises fica demonstrado que as topologias propostas têm resultados melhores que os conversores convencionais de dois-níveis (para as topologias de três braços, a 222 teve uma distorção harmônica de tensão total de 0,78% e as topologias híbridas 322 e 323, com 0,67% e 0,46%, respectivamente). Algumas topologias propostas apresentaram desempenho equivalente ao observado nos conversores convencionais de três-níveis (o rendimento da topologia de cinco braços 22322 foi igual ao da topologia convencional 33333, 0,94, utilizando um número reduzido de componentes). Resultados de simulação e experimentais dão suporte as análises realizadas.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleConversores estáticos utilizando estruturas de dois e três-níveis.pt_BR
dc.date.issued2015-08
dc.description.abstractThe reduction in complexity and cost of the static converters may be achieved through the use of topologies with few devices. Therefore, it is proposed in this paper the study of topologies of converters using arms of two and three-levels (NPC - Neutral Point Clamped) in its composition (hybrid topologies). For DC/AC power conversion, four configurations present in the literature will be studied. To AC/DC/AC conversion with three-wire loads, two conventional topologies and five proposals. For DC/AC conversion using four-wire loads, two conventional topologies and four proposals. For each presented topology, the following points were studied: modeling setup, PWM strategies, control strategy. Comparative studies have been conducted between the proposed and conventional topologies, evaluating their performance, through the parameters: voltage harmonic distortions, current harmonic distortions, switches losses and voltage bus. From the analysis it is shown that the proposed topologies have better results than conventional two-level converters (for three legs topologies, the 222 had a total voltage harmonic distortion of 0.78% and hybrid topologies 322 and 323, with 0.67% and 0.46%, respectively). Some proposed topologies exhibited performance equivalent to that observed in the conventional three-level converters (the efficiency of five legs proposed topology 22322 was equal to conventional topology 33333, 0.94, using a reduced number of components). Simulation results and experimental support the analyzes.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18191
dc.date.accessioned2021-04-19T19:55:05Z
dc.date.available2021-04-19
dc.date.available2021-04-19T19:55:05Z
dc.typeTesept_BR
dc.subjectConversores estáticospt_BR
dc.subjectEletrônica de potênciapt_BR
dc.subjectRedução de componentespt_BR
dc.subjectConversores trifásicos em pontept_BR
dc.subjectEstratégia PWMpt_BR
dc.subjectDistorção harmônicapt_BR
dc.subjectStatic Converterspt_BR
dc.subjectPower electronicspt_BR
dc.subjectComponent reductionpt_BR
dc.subjectThree-phase bridge converterspt_BR
dc.subjectPWM Strategypt_BR
dc.subjectHarmonic distortionpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorBARROS, Luciano de Macedo.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeStatic converters using two- and three-level structures.pt_BR
dc.identifier.citationBARROS, Luciano de Macedo. Conversores estáticos utilizando estruturas de dois e três-níveis. 2015. 239f. (Tese de Doutorado), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba - Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18191pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
LUCIANO DE MACEDO BARROS - TESE PPGEE 2015.pdfLuciano de Macedo Barros TESE PPGEE 201526.63 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.