Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1832
Full metadata record
DC FieldValueLanguage
dc.contributor.advisor1MACIEL, Theophilo Moura.-
dc.contributor.advisor1IDMACIEL, T. M.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9476858938351846pt_BR
dc.contributor.referee1CASTRO, Walman Benício de.-
dc.contributor.referee2FERREIRA, Ricardo Artur Sanguinetti.-
dc.contributor.referee3SANTOS, Marco Antonio dos.-
dc.description.resumoA necessidade de exploração de óleos mais pesados, em poços cada vez mais profundos e em ambientes mais agressivos tem causado falhas dos materiais por corrosão com grandes prejuízos econômicos e ambientais. Portanto este trabalho teve como objetivo avaliar a influência dos parâmetros de soldagem sobre a geometria (razão entre a altura e a largura- R/L), diluição(D), teor de Ferro, %Fe, e consequentemente resistência à corrosão de revestimentos de ligas de Ni (Hastelloy-276) aplicados por soldagem em aços C-Mn. O processo de soldagem utilizado foi ao Arco Submerso utilizando um arame eletrodo de liga de níquel (Ni-Cr-Mo-4) com diâmetro de 1,14 mm, avaliando duas modalidades de corrente, a corrente pulsada e a corrente convencional. Como substrato foi empregado segmentos de um tubo de aço de especificação API 5L Gr B com espessura de 18 mm e diâmetro interno de 290 mm. Para relacionar a influência das variáveis citadas com as respostas desejadas, foi utilizada a técnica de planejamento de experimentos com aplicação de planejamento fatorial em dois níveis. O planejamento fatorial foi utilizado apenas na etapa das soldagens dos cordões isolados. As etapas subseqüentes foram confeccionar revestimentos planos com três passes de solda e revestimentos circunferenciais com três passes no interior do tubo, com esse girando e a tocha parada, onde foi avaliado principalmente o teor de Fe e resistência à corrosão. Para os cordões isolados na modalidade de corrente pulsada, foram obtidos valores de diluição de 3,6% a 22,26% e valores de R/L de 0,23 a 0,67, sendo o resultado mais satisfatório de 12,76% e 0,28 para D e R/L respectivamente. Para os corões isolados na modalidade de corrente convencional, os valores de diluição variaram de 9,62% a 23,19%, com R/L variando de 0,21 a 0,60, sendo o resultado mais satisfatório de 11,81% e 0,28 para D e R/L. Nos revestimentos com três passes foram alcançados melhores resultados de resistência à corrosão na modalidade de corrente convencional, sendo a variável distância do bico de contato à peça, DBCP, de maior influência nos resultados.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM CIÊNCIA E ENGENHARIA DE MATERIAISpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia de Materiaispt_BR
dc.titleInfluência dos parâmetros de soldagem sobre as características de revestimentos de liga de níquel aplicados em aços API 5L Gr B pelo processo arco submerso.pt_BR
dc.date.issued2011-08-12-
dc.description.abstractThe need for exploration of heavier oils, in ever deeper wells and more aggressive environments has caused failures due to corrosion of materials with large economic and environmental losses. Therefore the aim of this study was to evaluate the influence of welding parameters on geometry (ratio of height to width - R/L), dilution (D), Iron content, % Fe, and hence corrosion resistance of Ni alloy overlays (Hastelloy-276) applied by welding on C-Mn steels. Submerged Arc welding process was used with pulsed and conventional current using nickel alloy wire electrode (Ni-Cr-Mo-4) with 1.14 mm diameter as filler metal. A segments of API 5L Gr B steel pipe with 18 mm thickness and 290 mm internal diameter was used as substrate. To relate the influence of the variables mentioned with the desired responses design of experiments technique with application of factorial design at two levels was used. The factorial design was used only in the stage of isolated welding beads. Subsequent steps consisted of overlay with 3 welding pass in plan position and inside of the pipe in rotation movement with the torch stopped. In this case it was also being evaluated mainly % Fe and corrosion resistance. For isolated beads in the pulsed current mode, dilution values were obtained from 3.6% to 22.26% and values of R / L from 0.23 to 0.67, being the most satisfactory result of 12.76% and 0.28 for D and R / L respectively. For isolated beads in the conventional current method,dilution values ranged from 9.62% to 23.19%, with R / L ranging from 0.21 to 0.60, being the most satisfactory result of 11.81% and 0.28 for D and R / L. At overlays with three passes, have been achieved better results in the corrosion resistance with conventional current mode, and the variable “distance from the contact tip to the workpiece, DBCP”, had the greatest influence on results.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1832-
dc.date.accessioned2018-09-27T15:03:02Z-
dc.date.available2018-09-27-
dc.date.available2018-09-27T15:03:02Z-
dc.typeDissertaçãopt_BR
dc.subjectSoldagempt_BR
dc.subjectProcesso ao Arco Submersopt_BR
dc.subjectHasteloy-276pt_BR
dc.subjectRevestimentopt_BR
dc.subjectDiluiçãopt_BR
dc.subjectPlanejamento Fatorialpt_BR
dc.subjectResistência à Corrosãopt_BR
dc.subjectWeldingpt_BR
dc.subjectSubmerged Arc Processpt_BR
dc.subjectOverlaypt_BR
dc.subjectDilutionpt_BR
dc.subjectFactorial Designpt_BR
dc.subjectResistance to Corrosionpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorBATISTA, Valmir Rodrigues.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeInfluence of welding parameters on the characteristics of nickel alloys overlays applied on API 5L Gr B steel by submerged arc process.pt_BR
dc.description.sponsorshipCNPqpt_BR
dc.relationCAPESpt_BR
dc.identifier.citationBATISTA, V. R. Influência dos parâmetros de soldagem sobre as características de revestimentos de liga de níquel aplicados em aços API 5L Gr B pelo processo arco submerso. 2011. 102 f. Dissertação (Mestrado em Ciência e Engenharia de Materiais) – Programa de Pós-Graduação em Ciência e Engenharia de Materiais, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2011. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/1832pt_BR
Appears in Collections:Mestrado em Ciência e Engenharia de Materiais.

Files in This Item:
File Description SizeFormat 
VALMIR RODRIGUES BATISTA - DISSERTAÇÃO PPG-CEMat CCT 2011.pdfValmir Rodrigues Batista - Dissertação PPG-CEMat CCT 20113.69 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.