dc.description.resumoA utilização de banco de capacitores em sistemas elétricos tem aumentado continuamente seguindo o crescimento da carga e consequentemente do próprio sistema. No entanto, a aplicação de Bancos de Capacitores necessita de cuidados pois podem ocorrer efeitos indesejados, principalmente quando se faz manobra no equipamento, entrando assim em transitórios severos que podem se propagar pelo sistema e causar os mais diversos danos. O ATP Draw (Alternative Transient Program) é um software dedicado para estudos eletromagnéticos, possuindo uma série de aplicações e vantagens. Por meio dele é possível modelar adequadamente os sistemas elétricos, reproduzindo a configuração real das redes elétricas. O presente trabalho tem por objetivo analisar por meio de software os transitórios capacitivos, bem como avaliar métodos de atenuação desse fenômeno. As simulações ocorreram de modo a seguir uma sequência definida: montagem do circuito, configuração dos elementos, configuração dos parâmetros de simulação, tratamento e analise dos resultados. Os resultados obtidos por simulação foram compatíveis com os obtidos a partir das expressões matemáticas deduzidas no texto e dos resultados reportados na literatura. Entretanto, para validação dos resultados obtidos faz – se necessário um estudo de campo realizando as montagens simuladas a fim de verificar a confiabilidade do método utilizado e confrontar os dados adquiridos.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleEstudo de transitórios causados por manobra de bancos de capacitores em redes elétricas.pt_BR
dc.date.issued2015
dc.description.abstractThe utilization of capacitors banks in electric systems have been being increased continuously following the system’s need. However, the application of capacitors banks need attention once may happen undesired problems, mainly while the equipment is in operational mode. Therefore, severe transitory may happen caused by the system and end up causing damage for the whole system. The ATP (Alternative Transient Program) is a software specialized in studies of electromagnetics, having several applications and advantages. Through this software, it is possible to create good electric systems reproducing the real configuration of the electric network. The present article has the objective of analyze through the software the capacitive transitory, as well study the methods of attenuation of this phenomenon. The simulations happened as the following: assembly the circuit; configuration of the elements; configuration of the parameters of simulation; treatment and analysis of the results. The results obtained by simulation were compatible with the ones obtained from the mathematical expressions, explained further in this article, and the results from the books. In contrast, to the validation of the collected results it is necessary a good study in a lab, making simulated circuits in a manner to get better results, verifying the quality of the method used, and confront the acquired results.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18477
dc.date.accessioned2021-04-30T18:27:57Z
dc.date.available2021-04-30
dc.date.available2021-04-30T18:27:57Z
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.subjectEstudo de transitóriospt_BR
dc.subjectManobra de banco de capacitorespt_BR
dc.subjectRedes elétricaspt_BR
dc.subjectBanco de capacitorespt_BR
dc.subjectTransitórios de energizaçãopt_BR
dc.subjectATP Drawpt_BR
dc.subjectAlternative Transient Programpt_BR
dc.subjectLigações de bancos de capacitorespt_BR
dc.subjectSobretensões de manobrapt_BR
dc.subjectTransient studypt_BR
dc.subjectCapacitor bank maneuverpt_BR
dc.subjectElectrical networkspt_BR
dc.subjectCapacitors bankpt_BR
dc.subjectEnergizing transientspt_BR
dc.subjectCapacitor bank connectionspt_BR
dc.subjectSwitching overvoltagespt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorSANTOS SOBRINHO, Antonio Mauricio dos.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeStudy of transients caused by maneuvering capacitor banks in electrical networks.pt_BR
dc.identifier.citationSANTOS SOBRINHO, Antonio Mauricio dos. Estudo de transitórios causados por manobra de bancos de capacitores em redes elétricas. 2015. 49f. (Trabalho de Conclusão de Curso - Monografia), Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba - Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18477pt_BR