Title: | Estruturas realimentadas com sensor termorresistivo aquecido a diferença de temperatura constante. |
Other Titles: | Structures fed back with a thermoresistive sensor heated to a constant temperature difference. |
???metadata.dc.creator???: | SILVA, Thais Luana Vidal de Negreiros da. |
???metadata.dc.contributor.advisor1???: | FREIRE, Raimundo Carlos Silvério. |
???metadata.dc.contributor.referee1???: | LUCIANO, Benedito Antonio. |
Keywords: | Sensor termoresistivo;Radiômetro;Sensor PTC;Sensor NTC;Circuitos realimentados com sensores termoresistivos;Medição de radiação;Diferença de temperatura constante;Thermoresistive sensor;Radiometer;PTC sensor;NTC sensor;Circuits feedback with thermoresistive sensors;Radiation measurement;Constant temperature difference |
Issue Date: | Mar-2015 |
Publisher: | Universidade Federal de Campina Grande |
Citation: | SILVA, Thais Luana Vidal de Negreiros da.Estruturas realimentadas com sensor termorresistivo aquecido a diferença de temperatura constante. 2015. 25f. (Trabalho de Conclusão de Curso - Monografia), Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba - Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18570 |
???metadata.dc.description.resumo???: | Neste trabalho, analisou-se a dinâmica de saída de um radiômetro utilizando sensores termorresistivos. Para tanto, foram desenvolvidas as expressões que regem o comportamento da tensão de saída (para as arquiteturas com saída analógica) e do duty cycle (para as arquiteturas com saída pulsada) em função da radiação, da temperatura ambiente e do T. Posteriormente, estas expressões foram simuladas no Matlab. Verificou-se que em T = 7 se tem maior sensibilidade da tensão de saída para as arquiteturas com saída analógica e radiação em torno de 1500 W/m2. Utilizando T = 7, simulou-se a dinâmica de saída em função da radiação para diferentes valores de temperatura ambiente. Observou-se que o sensor PTC é menos sensível à variação da temperatura ambiente do que o sensor NTC. Acerca da dependência da dinâmica de saída em relação à variação da temperatura ambiente, notou-se que, quanto maior a radiação, menor a influência da temperatura ambiente na tensão de saída. |
Abstract: | Output dynamic performance of radiometers based on thermoresistive sensors at Constant Temperature Difference (CTD) was studied on this work. Simulations of output dynamic voltage (for analog voltage architectures) and duty cycle (for pulsed voltage output architectures) according to radiation, environmental temperature and T were developed. All these expressions were simulated by using Matlab for PTC and NTC sensors. The analog output voltage circuits have better sensitivity at T = 7 for solar radiation at 1500 W/m2. The circuits using NTC sensors are more insensible to environmental temperature variations. Furthermore, increasing solar radiation level, environmental temperature variations have less influence on dynamic output performance. |
Keywords: | Sensor termoresistivo Radiômetro Sensor PTC Sensor NTC Circuitos realimentados com sensores termoresistivos Medição de radiação Diferença de temperatura constante Thermoresistive sensor Radiometer PTC sensor NTC sensor Circuits feedback with thermoresistive sensors Radiation measurement Constant temperature difference |
???metadata.dc.subject.cnpq???: | Engenharia Elétrica. |
URI: | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18570 |