Title: Análise da coordenação da proteção de distância em linhas de transmissão de circuito duplo.
Other Titles: Analysis of the coordination of distance protection in dual-circuit transmission lines.
???metadata.dc.creator???: MEIRA, Rafaella Nascimento.
???metadata.dc.contributor.advisor1???: BRITO, Núbia Silva Dantas.
Keywords: Proteção de distância - linhas de transmissão;Linhas de transmissão de circuito duplo - proteção;Filosofia da proteção;Relé de distância;Teleproteção - esquemas de;Software CAPE;Computer Aided Protection Engineering;Distance protection - transmission lines;Dual circuit transmission lines - protection;Protection philosophy;Distance relay;Teleprotection - protection schemes;CAPE software;Computer Aided Protection Engineering
Issue Date: Jun-2016
Publisher: Universidade Federal de Campina Grande
Citation: MEIRA, Rafaella Nascimento. Análise da coordenação da proteção de distância em linhas de transmissão de circuito duplo. 2016. 47f. (Trabalho de Conclusão de Curso - Monografia), Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba - Brasil, 2016. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18694
???metadata.dc.description.resumo???: Este trabalho analisa a coordenação da proteção em Linhas de Transmissão (LT) de circuito duplo, considerando que este tipo de LT requer uma atenção especial com relação à proteção, devido à indutância mútua inerente à mesma. É utilizada a proteção de distância para esquemas de teleproteção de Transferência de Trip de Sobrealcance Permissivo (Permissive Overreaching Transfer Trip - POTT) para acelerar a atuação do relé, garantindo que, em caso de falha de algum equipamento ou parte da rede, a mesma não prejudique a operação do sistema elétrico. A análise parte de um estudo de caso baseado em um sistema teste do Instituto de Engenheiros Eletricistas e Eletrônicos (IEEE), implementado no software CAPE (Computer Aided Protection Engineering), juntamente com todos os ajustes relativos ao relé digital SEL- 311C submetido a simulações de faltas, com o objetivo de validação do trabalho desenvolvido.
Abstract: This work analyzes the protection coordination of double-circuit transmission lines (TL), considering this type of TL require special attention with regard to the protection, due to mutual inductance inherent in it. It is used teleprotection for distance protection using Permissive Overreaching Transfer Trip (POTT) schemes to accelerate the relay performance, ensuring that in the event of failure of any equipment or part of the network, it does not jeopardize the operation the electrical system. The analysis part of an example based on the Institute of electrical and electronics engineers (IEEE) test system implemented in CAPE software (Computer Aided Protection Engineering), along with all the settings for the digital relay SEL- 311C subjected to fault simulations with the purpose of validating the work.
Keywords: Proteção de distância - linhas de transmissão
Linhas de transmissão de circuito duplo - proteção
Filosofia da proteção
Relé de distância
Teleproteção - esquemas de
Software CAPE
Computer Aided Protection Engineering
Distance protection - transmission lines
Dual circuit transmission lines - protection
Protection philosophy
Distance relay
Teleprotection - protection schemes
CAPE software
Computer Aided Protection Engineering
???metadata.dc.subject.cnpq???: Engenharia Elétrica.
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18694
Appears in Collections:Curso de Bacharelado em Engenharia Elétrica - CEEI - Monografias

Files in This Item:
File Description SizeFormat 
RAFAELLA NASCIMENTO MEIRA - TCC ENG. ELÉTRICA 2016.pdfRafaella Nascimento Meira - TCC Eng. Elétrica 2016.1.1 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.