Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18867
Full metadata record
DC FieldValueLanguage
dc.creator.IDMAGALHÃES, G. V. N.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/3741827966416437pt_BR
dc.contributor.advisor1SANTOS JÚNIOR, Gutemberg Gonçalves dos.
dc.contributor.advisor1IDSANTOS JÚNIOR, G. Gpt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0204301941083935pt_BR
dc.contributor.referee1LIMA, Antonio Marcus Nogueira.
dc.contributor.referee1IDLIMA, A. M. N.pt_BR
dc.description.resumoEm décadas passadas, mais de 600.000 dispositivos de estimulação cardíaca sofreram recall, 40% devido a problemas de software [8]. Isso mostra que desenvolver firmwares livres de bugs para esses sistemas ainda é um grande desafio, e que as metodologias usadas para validação não conseguem identificar cenários que levem esses equipamentos a falha. Por serem sistemas críticos, podendo causar danos à saúde dos pacientes ou até mesmo a morte, é de extrema importância desenvolver equipamentos com alto nível de confiabilidade. Isso incentiva, portanto, a formalização de uma metodologia de validação para esses dispositivos. Uma abordagem que se mostra pertinente, é a criação de uma plataforma que simule diferentes condições de batimentos cardíacos e que permita a conexão com marca-passos comerciais, de tal forma a conseguir estimular e detectar falhas nesses sistemas, possibilitando ainda o debug e o levantamento de uma cobertura de testes suficiente para validação de quaisquer desses dispositivos. Além disso, permite também a avaliação da conformidade desses dispositivos pelas Normas Brasileiras para equipamentos eletromédicos implantáveis, em especial, os marca-passos cardíacos. Ademais, a existência de alguns frameworks consagrados pela comunidade acadêmica para modelagem de batimentos cardíacos com e sem arritmias, à exemplo do Virtual Heart Model [2]-[3] desenvolvido pela University of Pennsylvania e disponibilizado de forma gratuita, mostra-se promissor a criação de uma plataforma com os requisitos estabelecidos.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleModelagem de arritmias cardíacas em hardware para validação e avaliação de marca-passos.pt_BR
dc.date.issued2018
dc.description.abstractIn past decades, more than 600,000 cardiac pacing devices have been recalled, 40 % due to software problems [8]. This shows that developing bugs-free firmwares for these systems is still a major challenge, and that the methodologies used for validation can not identify scenarios that lead to such failure. Because they are critical systems that can cause harm to patients’ health or even death, it is extremely important to develop equipment with a high level of reliability. This encourages, therefore, the formalization of a validation methodology for these devices. One approach that is pertinent is the creation of a platform that simulates different heartbeat conditions and allows the connection with commercial pacemakers, so as to be able to stimulate and detect flaws in these systems, also allowing the textit debug and the collection of sufficient test coverage for validation of any of these devices. In addition, it also allows the evaluation of the conformity of these devices by the Brazilian Standards (NBR) for implantable electromedical equipment, especially cardiac pacemakers. In addition, the existence of some frameworks established by the academic community for modeling heartbeats with and without arrhythmias, such as the Virtual Heart Model [2]-[3] developed by the University of Pennsylvania, is available free of charge. promising the creation of a platform with the established requirements.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18867
dc.date.accessioned2021-05-18T19:52:13Z
dc.date.available2021-05-18
dc.date.available2021-05-18T19:52:13Z
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.subjectModelagem de arritmias cardíacaspt_BR
dc.subjectMarca-passos avaliaçãopt_BR
dc.subjectTecnologia aplicada à cardiologiapt_BR
dc.subjectCardiologia - tecnologiapt_BR
dc.subjectDispositivos médicospt_BR
dc.subjectSistemas de tempo realpt_BR
dc.subjectSistemas cíber-físicospt_BR
dc.subjectAutômatospt_BR
dc.subjectVirtual Heart Model - VHMpt_BR
dc.subjectCoração - sistema de condução elétricopt_BR
dc.subjectPacemaker Verification Systempt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorMAGALHÃES, Gabriel Villanova Novaes.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeHardware cardiac arrhythmias modeling for pacemaker validation and evaluation.pt_BR
dc.identifier.citationMAGALHÃES, Gabriel Villanova Novaes. Modelagem de arritmias cardíacas em hardware para validação e avaliação de marca-passos. 2018. 68f. (Trabalho de Conclusão de Curso - Monografia), Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba - Brasil, 2018. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18867pt_BR
Appears in Collections:Curso de Bacharelado em Engenharia Elétrica - CEEI - Monografias

Files in This Item:
File Description SizeFormat 
GABRIEL VILLANOVA NOVAES MAGALHÃES - TCC ENG. ELÉTRICA 2018.pdfGabriel Villanova Novaes Magalhães - TCC Eng. Elétrica 2018.3.41 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.