Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19015
Title: Uma introdução ao estudo dos impactos da geração eólica na estabilidade do sistema.
Other Titles: An introduction to the study of the impacts of wind generation on the stability of the system.
???metadata.dc.creator???: DINIZ, Darlanny Silva.
???metadata.dc.contributor.advisor1???: BRITO, Núbia Silva Dantas.
???metadata.dc.contributor.referee1???: DANTAS, Karcius Marcelus Colaço.
Keywords: Energia eólica;Geração eólica - impactos;Impacto da geração eólica;Sistema eólico;Estabilidade de tensão;Curva P-V;Fluxo de potência continuado;ANAREDE;ANATEM;Wind energy;Wind generation - impacts;Impact of wind generation;Wind system;Voltage stability;P-V curve;Continued power flow
Issue Date: Dec-2019
Publisher: Universidade Federal de Campina Grande
Citation: DINIZ, Darlanny Silva. Uma introdução ao estudo dos impactos da geração eólica na estabilidade do sistema. 2019. 61f. (Trabalho de Conclusão de Curso - Monografia), Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba - Brasil, 2019. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19015
???metadata.dc.description.resumo???: Diante da escassez hídrica no país e dos avanços tecnológicos em fontes renováveis, o Sistema Interligado Nacional tem tido uma nova conjuntura com a intensa inserção de geração por fontes intermitentes. Dessa forma, a geração eólica tem atingido até 87% do suprimento diário da carga do Nordeste, proporcionando ao sistema uma maior complexidade de operação devido ao comportamento estocástico dos ventos. Assim, o presente trabalho aborda um breve estudo estacionário e dinâmico na estabilidade de tensão sob o comportamento das diferentes centrais eólicas mediante aos aspectos distintos dos ventos e perturbações no sistema. Para tanto, foi utilizado os fundamentos da literatura e simulações computacionais nos programas ANAREDE e ANATEM, cujo os resultados constataram variações nos níveis de tensão das barras conforme a variação dos ventos, pontos de máximo carregamento frente a aerogeradores de tecnologia distintas e resposta transitória do sistema frentes às centrais eólicas e aos geradores síncronos.
Abstract: Faced with water shortage in the country and technological advances in renewable sources, the National Interconnected System has had a new conjuncture with the intense insertion of generation by intermittent sources. Thus, wind generation has reached up to 87% of the daily Northeast cargo supply, providing the system with greater complexity of operation due to the stochastic wind behavior. So, the present work approaches a brief stationary and dynamic study on the voltage stability under the behavior of the different wind power plants by means of the distinct aspects of the wind and system disturbances. For this, we used the foundations of the literature and computer simulations in the programs ANAREDE and ANATEM, the results of which found variations in the voltage levels of the bars according to the variation of winds, maximum loading points in the face of different technology wind turbines and transitory system response in front of wind power plants and generators Synchronous.
Keywords: Energia eólica
Geração eólica - impactos
Impacto da geração eólica
Sistema eólico
Estabilidade de tensão
Curva P-V
Fluxo de potência continuado
ANAREDE
ANATEM
Wind energy
Wind generation - impacts
Impact of wind generation
Wind system
Voltage stability
P-V curve
Continued power flow
???metadata.dc.subject.cnpq???: Engenharia Elétrica.
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19015
Appears in Collections:Curso de Bacharelado em Engenharia Elétrica - CEEI - Monografias