Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19056
Title: Estudo do comportamento de transformadores de corrente em regime transitório, incluindo o efeito da histerese no núcleo magnético.
Other Titles: Study of the behavior of current transformers in transient regime, including the effect of hysteresis on the magnetic core.
???metadata.dc.creator???: CARDOSO, Lily da Silva.
???metadata.dc.contributor.advisor1???: GUERRA, Francisco das Chagas Fernandes.
Keywords: Transformadores de corrente em regime transitório;Histerese no núcleo magnético - transformadores;Fluxo residual;Modelo de Tellinen;Current transformers in transient regime;Hysteresis in the magnetic core - transformers;Residual flow;Tellinen model
Issue Date: 2019
Publisher: Universidade Federal de Campina Grande
Citation: CARDOSO, Lily da Silva. Estudo do comportamento de transformadores de corrente em regime transitório, incluindo o efeito da histerese no núcleo magnético. 2019. 55f. (Trabalho de Conclusão de Curso - Monografia), Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba - Brasil, 2019. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19056
???metadata.dc.description.resumo???: Neste trabalho é apresentado o estudo da Saturação em TC’S sob condições de regime transitório dado um sistema de potência, analisando seu comportamento com a presença da histerese e do religamento e sua influência diante das variações do ângulo de incidência do defeito, da componente indutiva da carga, do módulo da impedância da carga e do fluxo residual, para tanto é feito um embasamento teórico pautado na familiarização a respeito das características dos transformadores de corrente, sejam estruturais ou sejam elétricas e suas conformidades segundo a norma NBR 6856, assim como a apresentação do equacionamento necessário para a definição das variáveis envolvidas no objeto de estudo como no desenvolvimento do modelo de Juhani Tellinen, concluindo-se que alguns desses casos devem ser previstos e evitados durante o dimensionamento do TC e projeção do sistema.
Abstract: In this work is presented the study of saturation in TC'S under transient regime conditions given a power system, analyzing its behavior with and without the presence of hysteresis and reclosing and its influence on the variations of the incidence angle of the defect, the inductive component of the load, the load impedance module and the residual flow, the theoretical basis is based on familiarization about the characteristics of the current transformers, either structural or electrical and their conformity according to NBR 6856, as well as the presentation of the necessary equation for the definition of the variables involved in the object of study as in the development of the model of Juhani Tellinen, concluding that some of these cases should be anticipated and avoided during TC sizing and system design.
Keywords: Transformadores de corrente em regime transitório
Histerese no núcleo magnético - transformadores
Fluxo residual
Modelo de Tellinen
Current transformers in transient regime
Hysteresis in the magnetic core - transformers
Residual flow
Tellinen model
???metadata.dc.subject.cnpq???: Engenharia Elétrica.
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19056
Appears in Collections:Curso de Bacharelado em Engenharia Elétrica - CEEI - Monografias

Files in This Item:
File Description SizeFormat 
LILY DA SILVA CARDOSO - TCC ENG. ELÉTRICA 2019.pdfLily da Silva Cardoso - TCC Eng. Elétrica 2019. 1.95 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.