Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19405
Title: Uma análise energética do Hospital Pedro I.
Other Titles: An energetic analysis of Hospital Pedro I.
???metadata.dc.creator???: VILAR, Pablo Bezerra.
???metadata.dc.contributor.advisor1???: FERREIRA, Tarso Vilela.
???metadata.dc.contributor.referee1???: ALMEIDA, Genoilton João de Carvalho.
Keywords: Estágio em Engenharia Elétrica;Análise energética;Hospital Pedro I;Eficiência energética;Qualímetro;Consumo de energia;Revisão tarifária;Internship in Electrical Engineering;Energy analysis;Hospital Pedro I;Energy efficiency;Qualimeter;Energy consumption;Tariff review
Issue Date: Feb-2011
Publisher: Universidade Federal de Campina Grande
Citation: VILAR, Pablo Bezerra. Uma análise energética do Hospital Pedro I. 2011. 46f. (Relatório de Estágio Supervisionado) Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2011. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19405
???metadata.dc.description.resumo???: Este trabalho buscou, de forma geral, otimizar o uso da energia elétrica no Hospital Pedro I, visando sobretudo a redução dos custos. Com este intuito, foram focadas quatro áreas distintas: revisão contratual, utilização de uma fonte secundária de energia, reestruturação da iluminação de ambientes internos e análise das grandezas elétricas das instalações do hospital. Nessa última área, as grandezas foram obtidas com o auxilio de um qualímetro. Das quatro abordagens adotas para redução de consumo, apenas as modificações da iluminação e as modificações baseadas nos dados obtidos com o qualímetro podem ser aplicadas em curto prazo. A revisão contratual é uma opção bastante viável, porém só poderá ser aplicada a partir de junho de 2011, quando estará formada uma base dados mais confiável acerca do consumo do hospital. Isto se deve a alterações recentes ocorridas na carga total do hospital.O uso de fonte alternativa de energia mostrou-se pouco viável, devido ao elevado custo do óleo diesel.
Abstract: This work attempted to optimize the usage o electrical energy on Hospital Pedro I aiming the reduction of costs. With this goal the work focused on four distinct areas: Contractual Review, The usage of a secondary energy source, Restructuration of the internal illumination of the hospitals building and the analysis of electrical parameters of the hospitals installations, this data was acquired using a qualimeter. Only the modifications on the internal illumination and the conclusions about the data acquired with the qualimeter may be applied in short time The contractual review is a viable option but it cannot be applied at least until june of 2011, when a solid database regarding the hospital consume will be ready due to modifications occurred on the total load of the Hospital. The usage of an alternative energy source is not viable due the high cost of diesel.
Keywords: Estágio em Engenharia Elétrica
Análise energética
Hospital Pedro I
Eficiência energética
Qualímetro
Consumo de energia
Revisão tarifária
Internship in Electrical Engineering
Energy analysis
Hospital Pedro I
Energy efficiency
Qualimeter
Energy consumption
Tariff review
???metadata.dc.subject.cnpq???: Engenharia Elétrica.
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19405
Appears in Collections:Curso de Bacharelado em Engenharia Elétrica - CEEI - Relatórios de Estágio

Files in This Item:
File Description SizeFormat 
PABLO BEZERRA VILAR - RELATÓRIO DE ESTÁGIO ENG. ELÉTRICA 2011.pdfPablo Bezerra Vilar - Relatório de Estágio Eng. Elétrica 2011. 1.73 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.