Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19984
Full metadata record
DC FieldValueLanguage
dc.creator.IDCAMPOS, M.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/7207601062237405pt_BR
dc.contributor.advisor1LIMA, Antonio Marcus Nogueira.
dc.contributor.advisor1IDLIMA, A. M. N.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2237395961717699pt_BR
dc.contributor.advisor2OLIVEIRA, Alexandre Cunha.
dc.contributor.advisor2IDOLIVEIRA, A. C.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/6699829609793478pt_BR
dc.contributor.referee1CANHA, Luciane Neves.
dc.contributor.referee2SOUZA, Benemar Alencar de.
dc.contributor.referee3JACOBINA, Cursino Brandão.
dc.contributor.referee4COSTA, Flávio Bezerra.
dc.description.resumoDe uma forma geral todos sistemas elétricos estão susceptíveis a faltas. Todavia, existem faltas que não são detectadas pelo sistema de proteção, como por exemplo, a causada por galhos de árvores que tocam a rede elétrica ou ainda um rompimento de cabo sob uma superfície isolante tal como asfalto. Estas faltas são conhecidas como faltas de alta impedância (FAI). As FAI se apresentam como um desafio e normalmente não são detectadas pela proteção do sistema. Neste trabalho, foi realizado um estudo detalhado de técnicas de detecção de FAI apresentadas na literatura, identificando-se as condições em que cada uma apresenta melhor comportamento em termos de detecção, bem como as eventuais deficiências de cada uma das técnicas estudadas. As técnicas existentes podem ser classificadas em Passivas e Ativas. Das técnicas passivas foram escolhidas cinco para que fosse realizado um estudo comparativo de forma equilibrada partindo-se de um mesmo cenário e avaliando todas as técnicas sob as mesmas condições de análise. Uma técnica ativa também foi estudada, sob a ótica principalmente de desempenho. Baseado em todos estes estudos, foi proposta uma alteração da técnica ativa, esta modificação resultou em um melhor desempenho comparado a original. Para completar este estudo, este trabalho apresenta uma metodologia para a combinação das técnicas passivas de detecção de FAI. A técnica baseada na observação dos Harmônicos de baixa ordem de sequência negativa, foi combinada transformada wavelets. Por fim, foi utilizada uma rede neural artificial para que produzisse um diagnóstico, uma vez que é necessária a combinação de dois resultados para permitir a detecção precisa da condição de falta. Esta metodologia permitiu a distinção dos eventos do sistema e a correta detecção das faltas em todos os casos.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleDetecção de faltas de alta impedância em sistemas de distribuição primários de energia elétrica.pt_BR
dc.date.issued2017-12-07
dc.description.abstractIn general, all electrical systems are susceptible to failure. However, there are faults that are not detected by the protection system, such as those caused by tree branches that hit the power grid or a cable break under an insulating surface such as asphalt. These faults are known as high impedance faults (HIF). HIF present themselves as a challenge and cannot be detected by traditional methods. In this work, a detailed study of detection techniques for high impedance faults presented in technical literature was carried out, identifying the conditions in which each improves detection behavior as well as possible deficiencies in each technique studied. The techniques existing in the literature can be classified as either passive or active. From the passive techniques present in the literature, five were chosen so that a comparative study could be carried out in a balanced way, starting with the same scenario and evaluating all the techniques under the same conditions. An active technique has also been studied from the standpoint of performance in terms of detectability and type of fault. Based on all these studies a change was proposed in the active technique. These modifications resulted in improved performance compared to the original. In order to complete this study, this work presents the possibility of combining the passive techniques for detecting HIF. The technique based on the observation of low order harmonics of negative sequence was combined with the technique based on wavelets. An artificial neural network was used to produce a final result, since it is necessary to combine two results to allow precise diagnosis of the fault condition. This combination allowed the detectors to distinguish the events in the system and correct detection of the faults in all cases.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19984
dc.date.accessioned2021-07-12T16:54:18Z
dc.date.available2021-07-12
dc.date.available2021-07-12T16:54:18Z
dc.typeTesept_BR
dc.subjectFaltas em sistemas de distribuição elétricospt_BR
dc.subjectFaltas de alta impedância - detecçãopt_BR
dc.subjectSistemas de distribuição primáriospt_BR
dc.subjectProcessamento de energiapt_BR
dc.subjectModelagem do sistema de distribuição de energiapt_BR
dc.subjectMétodos de detecção de faltaspt_BR
dc.subjectDetecção de falta de alta impedância por assinaturapt_BR
dc.subjectHarmônicos de baixa ordempt_BR
dc.subjectTransformada de Waveletspt_BR
dc.subjectRedes neurais artificiaispt_BR
dc.subjectFaults in electrical distribution systemspt_BR
dc.subjectHigh impedance faults - detectionpt_BR
dc.subjectPrimary distribution systemspt_BR
dc.subjectEnergy processingpt_BR
dc.subjectModeling the power distribution systempt_BR
dc.subjectFault Detection Methodspt_BR
dc.subjectSignature High Impedance Miss Detectionpt_BR
dc.subjectLow order harmonicspt_BR
dc.subjectWavelets Transformpt_BR
dc.subjectArtificial neural networkspt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorCAMPOS, Maurício de.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeDetection of high impedance faults in primary power distribution systems.pt_BR
dc.identifier.citationCAMPOS, Maurício de. Detecção de faltas de alta impedância em sistemas de distribuição primários de energia elétrica. 2017. 151f. (Tese de Doutorado) Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19984pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
MAURÍCIO DE CAMPOS - - TESE PPGEE 2017.pdfMaurício de Campos - Tese PPGEE 2017.5.96 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.