Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20187
Full metadata record
DC FieldValueLanguage
dc.creator.IDPEDRO, H .J. G.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/9620256708244128pt_BR
dc.contributor.advisor1FONTGALLAND, Glauco.
dc.contributor.advisor1IDFONTGALLAND, G.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4256595317953538pt_BR
dc.contributor.advisor2RODRIGUES, Raquel Aline Araújo.
dc.contributor.advisor2IDRODRIGUES, R. A. A.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/4655728179608279pt_BR
dc.contributor.referee1QUEIROZ, Wamberto José Lira de.
dc.contributor.referee2CARVALHO, Joabson Nogueira de.
dc.description.resumoA câmara de reverberação é um ambiente de testes utilizado para avaliar a compatibilidade eletromagnética de um equipamento eletrônico. No interior da câmara de reverberação háumvolume chamado de zona de campo uniforme, onde o equipamento sob teste é posicionado. Nesse volume, o valor do desvio padrão do campo elétrico não pode ultrapassar 3 dB. A posição do equipamento sob teste pode elevar desvio padrão do campo elétrico no interior da zona de campo uniforme. Nesse sentido, é importante verificar, equalizar e reduzir os valores do desvio padrão de cada componente do campo elétrico. O desvio padrão pode ser utilizado como métrica de desempenho, porém para avaliar o desempenho da câmara de reverberação e dos agitadores é necessário escolher um conjunto de métricas que possam caracterizar diferentes aspectos do campo elétrico no interior da câmara, permitindo investigar a convergência dos resultados. Cada métrica de desempenho é obtida por meio da medição do campo elétrico em um ou mais vértices da zona de campo uniforme. Neste trabalho, foi empregado um conjunto de métricas de desempenho mais comuns na literatura, como: coeficiente de anisotropia, coeficiente de não-homogeneidade, desvio padrão e fator de qualidade. Os resultados foram obtidos na faixa de 700 MHz a 3 GHz, permitindo comprovar que a redução da área útil, a introdução de rugosidade e o emprego de ângulos de abertura nas pás do agitador contribuem para o aumento da faixa de operação (em 150 MHz) da câmara de reverberação, redução e equalização do desvio padrão (na faixa de frequências de 1,35 GHz a 3 GHz) no interior da zona de campo uniforme, permitindo que o equipamento sob teste possa ser testado independente de sua posição.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleEqualização do desvio padrão do campo elétrico em uma câmara de reverberação compacta.pt_BR
dc.date.issued2017-12-22
dc.description.abstractA reverberation chamber is a test environment used to evaluate the electromagnetic compatibility of electronic equipment. Inside the Reverb chamber there is a volume called the uniform field zone where the equipment under test is positioned. In this volume the value of the standard deviation of the electric field can not exceed 3 dB. The position of the equipment under test may raise the standard deviation of the electric field within the uniform field zone. In this sense, it is important to verify, equalize and reduce the values of the electric field component standard. The standard deviation can be used as a performance metric, but to evaluate the performance of the reverberation chamber and the stirrers it is necessary to choose a set of metrics that can characterize different aspects of the electric field without interior of the chamber, allowing to investigate a convergence of the results. Each performance metric is obtained by measuring the electric field at one or more vertices of the uniform field zone. In this work, we used a set of performance metrics more common in the literature as: coefficient of anisotropy, coefficient of non-homogeneity, standard pattern and quality factor. The results were obtained in the range of 700 MHz to 3 GHz, allowing to prove that the reduction of the working area, the introduction of roughness and the use of opening angles in the blades of the agitator contribute to the increase of the operating range (in 150 MHz) of the reverberation chamber, reduction and equalization of the standard deviation (from 1.35 GHz to 3 GHz) within the uniform field zone, allowing the equipment under test to be tested regardless of its position.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20187
dc.date.accessioned2021-07-22T16:51:43Z
dc.date.available2021-07-22
dc.date.available2021-07-22T16:51:43Z
dc.typeDissertaçãopt_BR
dc.subjectEstágio em Engenharia Elétricapt_BR
dc.subjectCâmara de reverberaçãopt_BR
dc.subjectCampo elétrico - anisotropiapt_BR
dc.subjectEqualização do desvio padrãopt_BR
dc.subjectAgitador de modospt_BR
dc.subjectAnisotropia do campo elétricopt_BR
dc.subjectEquações de Maxwellpt_BR
dc.subjectCavidade retangular ressonantept_BR
dc.subjectMotor de passopt_BR
dc.subjectInternship in Electrical Engineeringpt_BR
dc.subjectReverberation chamberpt_BR
dc.subjectElectric field - anisotropypt_BR
dc.subjectStandard deviation equalizationpt_BR
dc.subjectMode shakerpt_BR
dc.subjectElectric field anisotropypt_BR
dc.subjectMaxwell's Equationspt_BR
dc.subjectResonant rectangular cavitypt_BR
dc.subjectStepper motorpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorPEDRO, Haslan José Gonçalves.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeStandard deviation equalization of the electric field in a compact reverb chamber.pt_BR
dc.identifier.citationPEDRO, Haslan José Gonçalves. Equalização do desvio padrão do campo elétrico em uma câmara de reverberação compacta. 2017. 81f. (Dissertação de Mestrado) Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20187pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
HASLAN JOSÉ GONÇALVES PEDRO - DISSERTAÇÃO PPGEE 2017.pdfHaslan José Gonçalves Pedro - Dissertação PPGEE 2017.2.32 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.