Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20226
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator.ID | FERREIRA, R. S. A. | pt_BR |
dc.creator.Lattes | http://lattes.cnpq.br/1009418948225054 | pt_BR |
dc.contributor.advisor1 | COSTA, Edson Guedes da. | |
dc.contributor.advisor1ID | COSTA, E. G. | pt_BR |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/3930289115658143 | pt_BR |
dc.contributor.advisor2 | GUERRA, Francisco das Chagas Fernandes. | |
dc.contributor.advisor2ID | GUERRA, F. C. F. | pt_BR |
dc.contributor.advisor2Lattes | http://lattes.cnpq.br/1912783247913427 | pt_BR |
dc.contributor.referee1 | NEVES, Washington Luiz Araújo. | |
dc.contributor.referee1ID | NEVES, W. L. A. | pt_BR |
dc.contributor.referee2 | LUCIANO, Benedito Antonio. | |
dc.contributor.referee2ID | LUCIANO, B. A. | pt_BR |
dc.contributor.referee3 | FERREIRA, Tarso Vilela. | |
dc.contributor.referee3ID | FERREIRA, T. V. | pt_BR |
dc.description.resumo | Neste trabalho é apresentada uma avaliação da influência das forças eletromagnéticas nos entreferros de transformadores de corrente de proteção. A avaliação é desenvolvida a partir da verificação da resposta transitória de transformadores de corrente de proteção, considerando os deslocamentos nos entreferros provocados pelas forças eletromagnéticas. Para tanto, foi avaliada a influência das forças eletromagnéticas no núcleo de transformadores de corrente com 8 mm, 16 mm e 24 mm, de comprimento efetivo do entreferro e em seguida, com diferentes distribuições de entreferros no núcleo. A partir do desenvolvimento de simulações computacionais baseadas no Método dos Elementos Finitos, foi possível determinar as forças eletromagnéticas e os deslocamentos nos entreferros. De acordo com os resultados obtidos nesta pesquisa, concluiu-se que as forças eletromagnéticas que atuam nos entreferros de transformadores de corrente de proteção, em condições de regime permanente e curto-circuito, não influenciam a resposta do transformador de corrente para nenhum dos casos avaliados. | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Centro de Engenharia Elétrica e Informática - CEEI | pt_BR |
dc.publisher.program | PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA | pt_BR |
dc.publisher.initials | UFCG | pt_BR |
dc.subject.cnpq | Engenharia Elétrica. | pt_BR |
dc.title | Avaliação da influência das forças eletromagnéticas nos entreferros de transformadores de corrente de proteção. | pt_BR |
dc.date.issued | 2017-12-04 | |
dc.description.abstract | The evaluation of the influence of electromagnetic forces in the gaps of protective current transformers is presented in this work. The evaluation is developed from the verification of the transient response of protective current transformers, considering the displacements in the gaps caused by the electromagnetic forces. Therefore, it was evaluated the influence of the electromagnetic forces for protective current transformers with 8 mm, 16 mm and 24 mm gap length, and then, with different gap distributions in the core. The development of computational simulations based on the Finite Element Method, made it possible to determine the electromagnetic forces and the displacements in the gaps. According to the results obtained in this research, it was concluded that the electromagnetic forces acting on the protective current transformer gaps, under conditions of permanent regime and short circuit, do not influence the current transformer response for any of the cases evaluated. | pt_BR |
dc.identifier.uri | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20226 | |
dc.date.accessioned | 2021-07-23T18:40:44Z | |
dc.date.available | 2021-07-23 | |
dc.date.available | 2021-07-23T18:40:44Z | |
dc.type | Dissertação | pt_BR |
dc.subject | Forças eletromagnéticas | pt_BR |
dc.subject | Transformadores de corrente de proteção | pt_BR |
dc.subject | Eletromecânica | pt_BR |
dc.subject | Curto-circuito | pt_BR |
dc.subject | Entreferros - deslocamento | pt_BR |
dc.subject | Método dos elementos finitos | pt_BR |
dc.subject | Simulação multifísica | pt_BR |
dc.subject | Corrente de curto-circuito | pt_BR |
dc.subject | Histerese Jiles-Atherton - modelo | pt_BR |
dc.subject | Electromagnetic forces | pt_BR |
dc.subject | Protective Current Transformers | pt_BR |
dc.subject | Electromechanical | pt_BR |
dc.subject | Short circuit | pt_BR |
dc.subject | Air gaps - displacement | pt_BR |
dc.subject | Finite element method | pt_BR |
dc.subject | Multiphysics simulation | pt_BR |
dc.subject | Short circuit current | pt_BR |
dc.subject | Jiles-Atherton Hysteresis - Model | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.creator | FERREIRA, Regelii Suassuna de Andrade. | |
dc.publisher | Universidade Federal de Campina Grande | pt_BR |
dc.language | por | pt_BR |
dc.title.alternative | Evaluation of the influence of electromagnetic forces on the air gaps of protective current transformers. | pt_BR |
dc.identifier.citation | FERREIRA, Regelli Suassuna de Andrade. Avaliação da influência das forças eletromagnéticas nos entreferros de transformadores de corrente de proteção. 2017. 72f. (Dissertação de Mestrado) Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20226 | pt_BR |
Appears in Collections: | Mestrado em Engenharia Elétrica. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
REGELII SUASSUNA DE ANDRADE FERREIRA - DISSERTAÇÃO PPGEE 2017.pdf | Regelli Suassuna de Andrade Ferreira - Dissertação PPGEE 2017. | 1.53 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.