dc.creator.IDXAVIER, C. S. S.pt_BR
dc.contributor.advisor1COSTA, Edson Guedes da.
dc.contributor.advisor1IDCOSTA, E. G.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3930289115658143pt_BR
dc.contributor.referee1NEVES, Washington Luiz Araújo.
dc.contributor.referee1IDNEVES, W. L. A.pt_BR
dc.contributor.referee2FERREIRA, Tarso Vilela.
dc.contributor.referee2IDFERREIRA, T. V.pt_BR
dc.description.resumoOs transformadores de potência com isolamento imerso em óleo mineral isolante são equipamentos de tecnologia consolidada, pouca alteração tem sido acrescentada aos projetos ao longo das últimas décadas. A mudança de cenário para um crescimento mais acentuado do Sistema Elétrico de Potência brasileiro necessita de potências bem maiores e, para acompanhar este crescimento em tempo hábil, o Operador Nacional do Sistema decidiu em 2011 exigir equipamentos que possam suportar sobrecargas diárias de longa e curta duração de 20% e 40%, respectivamente. Este requisito tem conseqüências diretas no projeto dos equipamentos, e também no projeto dos equipamentos das conexões aos transformadores nas subestações, secionadores, disjuntores, transformadores de corrente e nos barramentos em instalações antigas. A especificação técnica da Chesf foi alterada visando a atender às condições de sobrecarga. No entanto, o estudo do comportamento térmico dos transformadores de potência merece uma atenção especial desde a concepção dos equipamentos. Este trabalho tem o intuito de avaliar o projeto térmico de transformadores de potência adquiridos pela Chesf nos últimos dois anos através da análise de curvas da temperatura de hot-spot. É desejado que os resultados venham a contribuir e respaldar os requisitos técnicos das futuras especificações técnicas.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleAnálise de desempenho térmico de transformadores de potência com ciclo diário de sobrecarga planejada.pt_BR
dc.date.issued2014-10-31
dc.description.abstractThe oil-immersed transformers are consolidated technology equipment; little change has been added to the projects over the last decades. A change of scenery for stronger growth of the Brazilian Electric Power System needs more powers and to follow this growth during a transitional period, the National System Operator decided in 2011 to require equipment able to withstand diary load cycle with long and short overloading of 20% and 40%. This requirement has direct consequences in the design of equipment, and also in the design of other equipment from these transformers connections in substations, like switch disconnectors , circuit breakers, current transformers and buses in older installations. Chesf transformers technical specification was changed in order to meet these conditions of overload. However, the study of the thermal behavior of power transformers deserves special attention since the design of the equipment. This work aims to evaluate the thermal design of power transformers from Chesf system acquired in the last two years, through the analysis of temperature curves of hot-spot. It is desired that the results will contribute and support the technical requirements of future technical specifications.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20233
dc.date.accessioned2021-07-23T19:27:35Z
dc.date.available2021-07-23
dc.date.available2021-07-23T19:27:35Z
dc.typeDissertaçãopt_BR
dc.subjectTransformadores de potência - desempenho térmicopt_BR
dc.subjectSobrecarga planejadapt_BR
dc.subjectCiclo diário de sobrecarga planejadapt_BR
dc.subjectCurvas de hot-spotpt_BR
dc.subjectHot-spotpt_BR
dc.subjectTransformadores com óleo isolantept_BR
dc.subjectSistema térmico de transformadorpt_BR
dc.subjectÓleo mineral - transformadorespt_BR
dc.subjectComutadores em cargapt_BR
dc.subjectPower transformers - thermal performancept_BR
dc.subjectPlanned overloadpt_BR
dc.subjectPlanned overload daily cyclept_BR
dc.subjectHot-spot curvespt_BR
dc.subjectTransformers with insulating oilpt_BR
dc.subjectTransformer Thermal Systempt_BR
dc.subjectMineral oil - transformerspt_BR
dc.subjectOn-load switchespt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorXAVIER, Cinthia Souza dos Santos.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeThermal performance analysis of power transformers with daily planned overload cycle.pt_BR
dc.identifier.citationXAVIER, Cinthia Souza dos Santos. Análise de desempenho térmico de transformadores de potência com ciclo diário de sobrecarga planejada. 2014. 91f. (Dissertação de Mestrado) Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2014. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20233pt_BR