Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20248
Full metadata record
DC FieldValueLanguage
dc.creator.IDROCHA, P. H. V.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/4263182713137336
dc.contributor.advisor1FONTGALLAND, Glauco.
dc.contributor.advisor1IDFONTGALLAND, G.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4256595317953538pt_BR
dc.description.resumoOs isoladores vítreos de alta tensão são, ainda hoje, os principais equipamentos empregados nas linhas de transmissão. Embora haja uma tendência de substituição desses por poliméricos, ainda são predominantemente encontrados principalmente nas redes de transmissão em alta tensão de 69 kV, 230 kV e 500 kV. Localizados distribuidamente ao longo de uma extensa área territorial, os métodos e procedimentos de inspeção se tornam de difícil execução. As rotinas de inspeções preventivas e preditivas realizadas atualmente são dotadas de bastante subjetividade e possuem muitos fatores que restringem a sua implementação. Dependem exclusivamente da avaliação visual do técnico e em condições climáticas específicas: período noturno, mínima fonte de luminosidade, principalmente da lua, umidade relativa do ar elevada e o uso de binóculo. Outras técnicas de inspeção foram estudadas, porém não foram encontrados relatos da sua utilização nas empresas de energia, para as tensões mencionadas. Este trabalho apresenta um método para a realização de inspeção em isoladores de alta tensão. O diferencial do método está na utilização de técnicas de processamento de sinais em conjunto com inteligência artificial, para que assim o espectro eletromagnético irradiado por esses equipamentos, quando estão em operação, seja interpretado e classificado quanto ao nível de poluição dos isoladores. Assim, um critério objetivo é inserido no processo, proporcionando ao inspetor uma ferramenta mais eficiente e que não necessite exclusivamente de uma avaliação subjetiva. As redes neurais artificiais realizaram a classificação dos sinais após o processamento desses através da transformada Wavelet. Medições em laboratório e em campo foram realizadas para servirem de base de dados para o treinamento do método. Os melhores resultados mostram acertos acima de 96,5% em todas as medições realizadas.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleClassificação de isoladores de vidro de alta tensão a partir do espectro eletromagnético irradiado.pt_BR
dc.date.issued2014-12
dc.description.abstractThe glass high voltage insulators are, today, the main equipment used in transmission lines. Although a trend towards replacing them with polymers, are still predominantly found mainly in transmission networks for high voltage 69 kV, 230 kV and 500 kV. Located over an extensive geographical area, the methods and inspection procedures become difficult to perform. The routines of preventive and predictive inspections performed today are equipped with enough subjectivity and have many factors that restrict its implementation. Depend solely on the visual assessment of the technical and specific climatic conditions: night, minimum source of light, especially the moon, high relative humidity and the use of binoculars. Other inspection techniques were studied, but have not found reports of their use in energy companies, for the mentioned tensions. This research presents a method for carrying out inspection on high voltage insulators. The differential method is the use of set in signal processing techniques with artificial intelligence, so that the electromagnetic spectrum radiated by the equipment when in operation, should be interpreted and classified according to the level of pollution of the insulators. Thus, an objective criterion is inserted in the process, giving the inspector a more efficient tool that does not require only a subjective assessment. Artificial neural networks performed the classification of signals after processing these through the wavelet transform. Measurements in the laboratory and field tests were conducted to serve as a database for training method. The best results show up hit 96.5% in all measurements.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20248
dc.date.accessioned2021-07-26T17:00:45Z
dc.date.available2021-07-26
dc.date.available2021-07-26T17:00:45Z
dc.typeDissertaçãopt_BR
dc.subjectIsoladores de vidro de alta tensãopt_BR
dc.subjectEspectro eletromagnético irradiadopt_BR
dc.subjectIsoladores de alta tensãopt_BR
dc.subjectRedes neurais artificiaispt_BR
dc.subjectReconhecimento de padrõespt_BR
dc.subjectTransformada de Waveletpt_BR
dc.subjectHigh Voltage Glass Insulatorspt_BR
dc.subjectRadiated electromagnetic spectrumpt_BR
dc.subjectHigh voltage insulatorspt_BR
dc.subjectArtificial neural networkspt_BR
dc.subjectPattern Recognitionpt_BR
dc.subjectWavelet Transformpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorROCHA, Pedro Henrique Venske da.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeClassification of high voltage glass insulators from the radiated electromagnetic spectrum.pt_BR
dc.identifier.citationROCHA, Pedro Henrique Venske da. Classificação de isoladores de vidro de alta tensão a partir do espectro eletromagnético irradiado. 2014. 101f. (Dissertação de Mestrado) Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2014. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20248pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
PEDRO HENRIQUE VENSKE DA ROCHA - DISSERTAÇÃO PPGEE 2014.pdfPedro Henrique Venske da Rocha - Dissertação PPGEE 2014.4.29 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.