Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2076
Full metadata record
DC FieldValueLanguage
dc.creator.IDOLIVEIRA, M. B. L.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6645179913028377pt_BR
dc.contributor.advisor1LEITÃO, Mário de Miranda Vilas Boas Ramos.-
dc.contributor.advisor1IDLEITÃO, Antônio Ocimar Manzi.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/7305189524186801pt_BR
dc.contributor.advisor2MANZI, Antonio Ocimar.-
dc.contributor.advisor2IDMANZI, A. O.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/0575383574431005pt_BR
dc.contributor.referee1SILVA, Bernardo Barbosa da.-
dc.contributor.referee2ESPÍNOLA SOBRINHO, José.-
dc.description.resumoA presente pesquisa teve como objetivo estudar o comportamento dos componentes do balanço de energia em épocas de cheia e de seca no Pantanal Sul Matogrossense, devido à superfície do Pantanal apresentar grandes contrastes entre essas duas épocas. Isto basicamente ocorre porque na maioria dos anos, na época de cheia, forma-se uma lâmina de água sobre a superfície que abrange uma extensa área. Os dados foram coletados durante a execução do Projeto Estudos da Camada Limite Superficial do Pantanal Sul Matogrossense, cuja base experimental foi a Fazenda São Bento (19°34' S; 57°01' W), que está localizada na área da Base de Estudos do Pantanal, pertencente à Universidade Federal do Mato Grosso do Sul, às margens do Rio Miranda, distrito de Passo do Lontra, município de Corumbá - MS. Para obtenção dos dados utilizou-se uma torre de 21 metros de altura, onde foram instalados sensores eletrônicos de alta e baixa frequência. Próximo da torre também foram instalados sensores no solo para completar as medidas das componentes do balanço de energia. Os resultados mostraram que durante o período de estudo a temperatura média diária variou predominantemente entre 25 e 30°C nos meses de verão. No entanto, nos meses de inverno, devido à penetração de frentes frias na região, a temperatura alcançou valores de até 10°C. Já a umidade relativa do ar mostrou-se bastante variável ao longo do ano, apresentando valores mais baixos nos meses de menor índice de precipitação (inverno). O albedo apresentou valores mais elevados (cerca de 20%) no período seco e foi decrescendo à medida que as precipitações foram intensifícando-se, chegando a apresentar valores mínimos de cerca de 5% no final de dezembro de 2001, quando a lâmina de água sobre a superfície atingiu espessura máxima de 74cm. A presença de lâmina de água provocou alterações nos elementos climáticos estudados, bem como nos componentes dos balanços de radiação e de energia, à medida que houve aumento ou diminuição da espessura. Os totais diários do fluxo de calor latente mostraram valores da ordem de 18 MJ/m"2 no período de maior espessura da lâmina de água, o que representou 80% da energia disponível, enquanto que nos meses mais secos, chegou a atingir valores inferiores a 5 MJ/m"2, o que representou apenas cerca de 20% da energia disponível.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM METEOROLOGIApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqMeteorologia.pt_BR
dc.titleBalanço de energia e caracterização do microclima do Pantanal Sul Matogrossense em períodos de cheia e seca.pt_BR
dc.date.issued2004-03-03-
dc.description.abstractThe present research had as objective to study the behavior of the components of the energy balance in times of full and drought in the Pantanal Sul Matogrossense, due to the surface of the region to present great contrasts among those two times. This basically happens because in most of the years at that time of full, is formed a sheet of water on the surface that embraces an extensive area. The data were collected during the execution of Project Estudos da Camada Limite Superficial do Pantanal Sul Matogrossense, whose experimental base went to Fazenda São Bento (19° 34' S; 57° 01' W), that is located in the area of studies of the Swampland, belonging to the Universidade Federal do Mato Grosso do Sul, in the margins of Miranda river, Passo do Lontra, municipal district of Corumbá MS. For obtaining of the data a tower of 21 height meters was used, where were installed sensors electronic of high and low frequency. Close of the tower were also installed sensor in the soil to complete the measures of the components of the swinging of energy. The results showed that during the study period, the temperature measured daily it varied predominantly between 25 and 30°C in the months of summer, however, in the months of winter due to penetration of cold fronts in the area the temperature reached values of up to 10°C. The relative humidity of the air was already shown plenty of variable along the year, presenting lower values in the months of smaller precipitation index (winter). The albedo presented higher values (about 20%) in the dry period and went decreasing the measure in that the precipitations went intensifying, getting to present minimum values of about 5% in the end of December of 2001, when laminates of water on the surface reached thickness maximum of 74 cm. The presence of laminates of water provoked alterations in the studied climatic elements, as well as in the components of the radiation and energy balance, the measure in that there were increase or decrease of the thickness. The totais diary of flow of latent heat showed values of the order of 18 MJ/m2 in the period of larger thickness of the laminates of water, what represented 80% of the available energy, while in the driest months, got to reach inferior values for 5 MJ/m2, what just represented about 20% of the available energy.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2076-
dc.date.accessioned2018-10-29T16:50:51Z-
dc.date.available2018-10-29-
dc.date.available2018-10-29T16:50:51Z-
dc.typeDissertaçãopt_BR
dc.subjectBalanço de energiapt_BR
dc.subjectCaracterização do microclimapt_BR
dc.subjectPantanal sul Matogrossensept_BR
dc.subjectBalanço de radiaçãopt_BR
dc.subjectPantanal Matogrossensept_BR
dc.subjectAlbedopt_BR
dc.subjectCamada limite atmosféricapt_BR
dc.subjectÉpoca de cheia - Pantanalpt_BR
dc.subjectÉpoca de seca - Pantanalpt_BR
dc.subjectBalanço de energiapt_BR
dc.subjectRadiation balancept_BR
dc.subjectCharacterization of the microclimatept_BR
dc.rightsAcesso Abertopt_BR
dc.creatorOLIVEIRA, Maria Betânia Leal de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeEnergy balance and characterization of the Pantanal Sul Matogrossense microclimate during flood and dry periods.pt_BR
dc.identifier.citationOLIVEIRA, Maria Betânia Leal de. Balanço de energia e caracterização do microclima do Pantanal Sul Matogrossense em períodos de cheia e seca. 2004. 124f. (Dissertação de Mestrado em Meteorologia), Programa de Pós-graduação em Meteorologia, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande – Paraíba – Brasil, 2004. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2076pt_BR
Appears in Collections:Mestrado em Meteorologia.

Files in This Item:
File Description SizeFormat 
MARIA BETÂNIA LEAL DE OLIVEIRA - DISSERTAÇÃO PPGMet 2004.pdfMaria Betânia Leal de Oliveira - Dissertação PPGMet 2004. 20.82 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.