dc.description.resumoA fragilização por hidrogênio, de um metal ou liga, é um problema industrial que pode levar a danos estruturais, quando em condições ótimas acontecerá. Com base nesta premissa o presente estudo teve como objetivo estudar o efeito mitigador da permeação do hidrogênio, pela liga Zn-Ni eletrodepositada sobre Aço SAE 1020. Esta liga, com baixo teor de carbono, é um dos aços mais comumente utilizados na indústria de processo, com excelente relação custo benefício comparado com outros aços destinados ao mesmo propósito. Foram escolhidas duas metodologias para galvanizar este aço com a liga Zn- Ni; uma a base de cloretos e outra a base de sulfatos, com intuito de comparar seus efeitos à permeação de hidrogênio. Inicialmente, foi realizada uma caracterização da corrosão eletroquímica destes e sua análise morfológica, onde ficou constatado que estes revestimentos protegem o metal de base tanto à corrosão quanto a difusão de hidrogênio, porém o processo de eletrodeposição do Zn-Ni a base de sulfatos obteve uma maior concentração de níquel e melhor resistência a corrosão de acordo com os dados obtidos e permeação. Os revestimentos de Zn-Ni diminuíram a susceptibilidade do SAE 1020 à permeação por hidrogênio; onde o revestimento a base de sulfatos obteve razão de alongamento de 95%.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Químicapt_BR
dc.titleAvaliação da permeação do hidrogênio através da liga Zn-Ni eletrodepositada sobre o aço SAE 1020.pt_BR
dc.date.issued2021-09-23-
dc.description.abstractThe embrittlement by hydrogen, of a metal or an alloy, is an industrial problem that can lead to structural damage, when in optimal conditions it will happen. Based on this premise, the present study aimed to study the mitigating effect of hydrogen permeation, by the Zn-Ni alloy electrodeposited on SAE 1020 Steel. This alloy, with low carbon content, is one of the most commonly used steels in the process industry , with an excellent cost-benefit ratio compared to other steels intended for the same purpose. Two methodologies were chosen to galvanize this steel with the Zn-Ni alloy; one based on chlorides and the other based on sulfates, in order to compare their effects to hydrogen permeation. Initially, a characterization of the electrochemical corrosion of these and its morphological analysis was performed, where it was found that these coatings protect the base metal both to corrosion and hydrogen diffusion, but the Zn-Ni electrodeposition process based on sulfates obtained a higher nickel concentration and better corrosion resistance according to the obtained data and permeation. Zn-Ni coatings decreased the susceptibility of SAE 1020 to hydrogen permeation; where the coating based on sulfates obtained an elongation ratio of 95%.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/22655-
dc.date.accessioned2021-12-20T15:32:47Z-
dc.date.available2021-12-20-
dc.date.available2021-12-20T15:32:47Z-
dc.typeTesept_BR
dc.subjectFragilização por hidrogêniopt_BR
dc.subjectPermeação por hidrogêniopt_BR
dc.subjectAço SAE 1020pt_BR
dc.subjectEletrodeposição de Zn-Nipt_BR
dc.subjectCorrosãopt_BR
dc.subjectHydrogen embrittlementpt_BR
dc.subjecthydrogen permeationpt_BR
dc.subjectSAE 1020 steelpt_BR
dc.subjectZn-Ni electrodepositionpt_BR
dc.subjectCorrosionpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorCARVALHO, João Paulo Dantas de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeEvaluation of hydrogen permeation through the Zn-Ni alloy electrodeposited on SAE 1020 steel.-
dc.description.sponsorshipCapespt_BR
dc.identifier.citationCARVALHO, João Paulo Dantas de. Avaliação da permeação do hidrogênio através da liga Zn-Ni eletrodepositada sobre o aço SAE 1020. 121f. Tese (Doutorado em Engenharia Química) - Programa de Pós- Graduação em Engenharia Química, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2021. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/22655pt_BR
Appears in Collections:Doutorado em Engenharia Química.

Files in This Item:
File Description SizeFormat 
JOÃO PAULO DANTAS DE CARVALHO - TESE PPGEQ 2021.pdfJoão Paulo Dantas de Carvalho - Tese PPGEQ 20217.19 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.