Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23949
Title: Análise experimental de consolos curtos de concreto reforçado com fibra de aço.
Other Titles: Experimental analysis of short steel fiber reinforced concrete corbels.
???metadata.dc.creator???: FERREIRA, Josyverton Gomes.
???metadata.dc.contributor.advisor1???: SIMPLÍCIO , Marcos Antônio de Souza.
???metadata.dc.contributor.referee1???: SILVA, José Bezerra da.
???metadata.dc.contributor.referee2???: SANTOS JÚNIOR., Marinaldo dos.
Keywords: Concreto com fibra de aço;Fibra de aço;Consolos curtos;Pré-moldados;Rupturas em consolos;Estruturas;Construção Civil;Concrete with steel fiber;Steel fiber;Short dildos;Precast;Breaks in dildos;Structure;Construction
Issue Date: 2017
Publisher: Universidade Federal de Campina Grande
Citation: FERREIRA, Josyverton Gomes. Análise experimental de consolos curtos de concreto reforçado com fibra de aço. 2017. 70f. Trabalho de Conclusão de Curso (Monografia), Curso de Bacharelado em Engenharia Civil, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande - Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23949
???metadata.dc.description.resumo???: Um dos problemas recorrentes na execução da pré-moldagem de estruturas é a necessidade das ligações entre os elementos com objetivo de garantir estabilidade e uma boa distribuição de esforços. O consolo é amplamente utilizado em estruturas pré- moldadas, pois serve como elemento de ligação entre dois componentes tais como viga- pilar. Apesar da eficiência na distribuição dos esforços, os consolos apresentam a dificuldade de concretagem no processo de pré-moldagem devido à grande taxa de armadura necessária em pouco espaço. Além da armadura do tirante principal, geralmente se utilizam estribos verticais e horizontais (Armadura de costura). Diante disto, esse trabalho surge com objetivo de estudar a influência da adição de fibras de aço ao concreto convencional utilizado na moldagem de consolos curtos visando a diminuição da armadura de costura e melhoria da característica frágil do concreto. A fase experimental foi dividida em duas (2) etapas: Ensaios de caracterização do material e ensaios mecânicos (Resistência à compressão simples, resistência à tração e ensaio destrutivo dos modelos). Foram ensaiados três modelos de consolos em que dois deles moldados sem incorporação de fibra sendo um com metade da armadura de costura (As,cost) e o outro com o As,cost total proposta pela NBR 9062/2006, e o terceiro com metade do armadura de costura e adição de 0,5% de fibra de aço. De modo geral essa pesquisa mostrou que a adição de fibras de aço ao concreto promoveu incrementos na capacidade de carga de consolos aumentando a carga última e a carga de início de fissuração do modelo ensaiado.
Abstract: One of the recurring problems in the implementation of the pre-molding of the structures is the need of the connections between the elements with the aim of ensuring stability and a good distribution of efforts. The corbels is widely used in pre -molded, in that it serves as a connecting element between two components such as beam-pillar. In spite of the efficiency in the distribution of efforts, the consolation presents the difficulty of concreting in the process of pre-molding due to the large amount of armor required in little space. In addition to the main strut armature, generally if they use stirrups in vertical and horizontal (Armor of sewing). Consequently, this work arises with the aim to study the influence of addition of steel fiber to the concrete in the conventional used in the molding of corbels short, aiming at reducing the armor's seam and the improvement of the characteristic of a fragile concrete. The experimental phase was divided into two (2) steps: Tests for material characterization and mechanical tests (Resistance to compression simple tensile strength testing and destructive of the models). Have been tested three models of corbels being two of them molded without incorporation of fiber one with half the armor of the seam (As,cost) and the other with the As,cost total proposed by the NBR 9062/2006, and the third with half of the armor stitching and addition of 0.5% steel fibre.In general this research showed that the addition of steel fiber to the concrete promoted increments in the load c apacity of corbels increasing the load of break and the Beginning of cracking of the model tested.
Keywords: Concreto com fibra de aço
Fibra de aço
Consolos curtos
Pré-moldados
Rupturas em consolos
Estruturas
Construção Civil
Concrete with steel fiber
Steel fiber
Short dildos
Precast
Breaks in dildos
Structure
Construction
???metadata.dc.subject.cnpq???: Engenharia Civil
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23949
Appears in Collections:Curso de Bacharelado em Engenharia Civil - CTRN - Monografias

Files in This Item:
File Description SizeFormat 
JOSYVERTON GOMES FERREIRA - TCC ENG. CIVIL CTRN 2017.pdfJosyverton Gomes Ferreira - TCC Eng. Civil CTRN 2017.3.7 MBAdobe PDFView/Open