Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24850
Full metadata record
DC FieldValueLanguage
dc.creator.Latteshttp://lattes.cnpq.br/2885917672271812pt_BR
dc.contributor.advisor1COSTA, Edson Guedes da.-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3930289115658143pt_BR
dc.contributor.advisor-co1NOBREGA, Luiz Augusto Medeiros Martins.-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/6667507308429720pt_BR
dc.contributor.referee1NEVES, Washington Luiz Araujo.-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/3107104665517286pt_BR
dc.contributor.referee2LIRA, George Rossany Soares de.-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/7283717300126094pt_BR
dc.description.resumoIsoladores poliméricos têm substituído paulatinamente isoladores cerâmicos em linhas de transmissão nas últimas décadas. Entretanto, ainda que isoladores poliméricos apresentem vantagens em relação aos cerâmicos, o seu diagnóstico é mais complexo e afetado em maior ou menor grau pela subjetividade do avaliador. A utilização de métodos de aprendizado de máquina pode mitigar esse problema. Todavia, há uma carência na bibliografia especializada da definição dos atributos de entrada mais significativos para esses métodos, bem como de bancos de dados representativos. Outro problema comumente observado é a elevada subjetividade durante a classificação inicial (rotulagem) dos isoladores. Nesse contexto, o presente trabalho tem como objetivo definir os atributos mais significativos oriundos das técnicas de inspeção por termografia infravermelha, detecção de radiação ultravioleta e ruído ultrassônico enquanto propõe uma metodologia para redução da subjetividade na classificação de isoladores. Também se pretendeu disponibilizar um banco de dados vasto e representativo. Para tanto, 60 isoladores retirados de uma linha de transmissão foram ensaiados em laboratório para extração de dados a partir de cada uma das técnicas citadas. Os dados foram processados e uma metodologia baseada em agrupamento difuso para redução da subjetividade na rotulagem de isoladores foi proposta, considerando ainda a inspeção visual em uma concepção conservadora. Três métodos de seleção de atributos foram utilizados para determinação dos atributos mais significativos, a saber: minimum Redundancy, Maximum Relevance, Relief-F e testes qui-quadrado. A partir dos resultados obtidos, constatou-se que atributos oriundos de ruído ultrassônico, mais precisamente da transformada wavelet de sinais de ruído ultrassônico, se apresentaram promissores para o diagnóstico de isoladores poliméricos, bem como atributos relacionados à localização de pontos quentes no corpo do isolador. Assim, os principais atributos elencados são: os locais de máximo para o aumento de temperatura, bem como para variações de temperatura e variações das variações; a assimetria dos coeficientes de detalhe do segundo nível da transformada Wavelet e a 1ª harmônica para os sinais de ruído ultrassônico. No entanto, os resultados demonstraram que a inspeção visual ainda é um critério importante para a classificação de isoladores. Resultados indicam que a metodologia proposta não é afetada pelas características ambientais nos ensaios, porém mais estudos são necessários. Novos trabalhos podem propor outros atributos, especialmente relativos à inspeção por detecção de radiação ultravioleta, bem como novos métodos de seleção de atributos.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia elétricapt_BR
dc.titleDefinição dos principais atributos para identificação do estado operacional de isoladores poliméricos por aprendizado de máquina.pt_BR
dc.date.issued2022-03-10-
dc.description.abstractPolymer insulators have gradually replaced ceramic insulators in transmission lines in the last decades. However, even though polymer insulators have advantages over ceramic ones, their diagnosis is more complex and affected to a greater or lesser degree by the subjectivity of the evaluator. The use of machine learning methods can mitigate this problem. However, specialized literature lacks on the definition of the most significant input features for these methods, as well as on representative databases. Another problem commonly observed is the high subjectivity during the initial classification (labeling) of insulators. In this context, the present work aims to determine the most significant features arising from the following inspection techniques: infrared thermography, detection of ultraviolet radiation and ultrasonic noise, while proposing a methodology for reducing subjectivity in the classification of insulators. It was also intended to provide a vast and representative database. Therefore, 60 polymer insulators removed from a transmission line were tested in laboratory to extract data from each of the aforementioned techniques. The data were processed and a methodology based on fuzzy clustering was proposed to reduce subjectivity in the labeling of insulators, considering the visual inspection in a conservative conception. Three feature selection methods were used to determine the most significant attributes, namely: minimum Redundancy, Maximum Relevance, Relief F and chi-square tests. From the results obtained, it was found that features from ultrasonic noise, more precisely from the wavelet transform of ultrasonic noise signals, were promising for the diagnosis of polymer insulators, as well as features related to the location of hot spots in the insulator body. Thus, the main attributes listed are the maximum locations for the temperature increase, as well as the temperature variations and variations of the variations; the asymmetry of the detail coefficients of the second level of the Wavelet transform and the first harmonic for the ultrasonic noise. However, the results showed that visual inspection is still an important criterion for classifying insulators. Results also indicate that the proposed methodology is not affected by the environmental characteristics in the tests, but more studies are needed. New works may propose other attributes, especially related to inspection by detection of ultraviolet radiation, as well as new methods of attribute selection.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24850-
dc.date.accessioned2022-04-26T12:51:09Z-
dc.date.available2022-04-26-
dc.date.available2022-04-26T12:51:09Z-
dc.typeDissertaçãopt_BR
dc.subjectSeleção de atributospt_BR
dc.subjectRedução de subjetividadept_BR
dc.subjectIsoladores poliméricospt_BR
dc.subjectBancos de dadospt_BR
dc.subjectFeature selectionpt_BR
dc.subjectSubjectitivy reductionpt_BR
dc.subjectPolymer insulatorspt_BR
dc.subjectDatabasespt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorSOUZA, João Pedro da Costa.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.description.sponsorshipCapespt_BR
dc.identifier.citationSOUZA, João Pedro da Costa. Definição dos principais atributos para identificação do estado operacional de isoladores poliméricos por aprendizado de máquina. 100 f. Dissertação (Mestrado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2022.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
JOÃO PEDRO DA COSTA SOUZA – DISSERTAÇÃO (PPGEE) 2022.pdf4.5 MBAdobe PDFView/Open