Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/250
Full metadata record
DC FieldValueLanguage
dc.creator.Latteshttp://lattes.cnpq.br/9066164039769600pt_BR
dc.contributor.advisor1SOUZA, Benemar Alencar de.-
dc.contributor.advisor1IDSOUZA, B. A.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4987294390789975pt_BR
dc.contributor.advisor-co1SIQUEIRA, Iony Patriota de.-
dc.contributor.advisor-co1IDSIQUEIRA, Iony Patriota de.pt_BR
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/6395538047388012pt_BR
dc.description.resumoEste trabalho visa a aplicação da metodologia Manutenção Centrada na Confiabilidade – MCC, através de um projeto piloto em uma unidade de manutenção de linhas de transmissão da Companhia Hidro Elétrica do São Francisco – Chesf. Devido às dificuldades da eliminação dos problemas da ocupação de faixa de linhas de transmissão, o objetivo desta aplicação é reduzir os riscos de acidentes com pessoas que ocupam estas áreas através da mudança nos processo da manutenção de linhas transmissão. Inicialmente é feita a apresentação dos componentes mais críticos das linhas de transmissão, sobre a ótica da segurança, e a identificação dos seus principais modos de falha, assim como, sobre as metodologias de manutenção de linhas de transmissão usadas atualmente. O processo de implantação é feito de forma sistemática e seguindo a estratégia clássica e sequenciada que é a seleção do sistema e coleta de informações, a análise de modos de falhas e efeitos, a seleção das funções significantes, e das atividades aplicáveis, a avaliação das atividades, em seguida é realizada a seleção das atividades para finalmente ser definida a periodicidade das atividades. Verifica-se a eficácia da metodologia, pois após as realização das análises necessárias, conclui-se que é necessário uma metodologia diferenciada para a manutenção de linhas de transmissão, cujas faixas de passagem foram ocupadas irregularmente, certamente a aplicação da metodologia contribuirá para o objetivo maior que é a redução dos riscos existentes nestas linhas de transmissão.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Eletrica.pt_BR
dc.subject.cnpqProcessamento de Energia.pt_BR
dc.titleManutenção centrada em confiabilidade aplicada à gestão de linhas de transmissão localizadas em áreas de ocupação irregular de faixa de passagem.pt_BR
dc.date.issued2014-
dc.description.abstractThis work aims at applying the methodology Reliability Centered Maintenance - RCM, through a pilot project in a maintenance unit transmission lines of the Companhia Hidro Elétrica do São Francisco – Chesf. Due to the difficulties of eliminating the problems of occupation range of transmission lines, the objective of this methodology is to reduce the risk of injury to persons occupying these areas through the change process in the maintenance of transmission lines. Initially the presentation of the most critical components of the transmission lines on the viewpoint of security, and identification of their major failure modes is taken as well as the methodologies for maintenance of transmission lines used today. The deployment process is done systematically and following the classic strategy and sequenced that is the selection of the system and information collection, analysis of failure modes and effects, the selection of the significant functions and activities applicable to assessment effectiveness of activities, then the selection of effective activities is made the frequency of activities to finally be set. Verifies the effectiveness of the methodology, since after the requisite tests, it is concluded that a different methodology for the maintenance of transmission lines present in areas of irregular occupation of track is required in addition to application of Reliability Centered Maintenance brings us to our goal is the reduction of existing risks in these transmission lines.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/250-
dc.date.accessioned2018-02-02T12:32:22Z-
dc.date.available2018-02-02-
dc.date.available2018-02-02T12:32:22Z-
dc.typeDissertaçãopt_BR
dc.subjectLinhas de Transmissão.pt_BR
dc.subjectManutenção Centrada na Confiabilidade.pt_BR
dc.subjectOcupação.pt_BR
dc.subjectFavelas.pt_BR
dc.subjectTransmission Lines.pt_BR
dc.subjectReliability Centered Maintenance.pt_BR
dc.subjectOcupation.pt_BR
dc.subjectIrregular Housing.pt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorSOUZA, Antonio Carlos Vieira de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.identifier.citationSOUZA, Antonio Carlos Vieira de. Manutenção centrada em confiabilidade aplicada à gestão de linhas transmissão localizadas em áreas de ocupação irregular de faixa de passagem. 2014. 131 f. Dissertação (Mestrado em Sistemas de Energia Elétrica) – Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2014.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
ANTONIO CARLOS VIEIRA DE SOUZA – DISSERTAÇÃO PPGEE 2014.pdfAntonio Carlos Vieira de Souza - Dissertação PPGEE 20135.22 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.