Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/25819
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator.ID | SILVA, R. M. M. | pt_BR |
dc.creator.Lattes | http://lattes.cnpq.br/4462337110259030 | pt_BR |
dc.contributor.advisor1 | RODRIGUES, Rodrigo Araújo. | - |
dc.contributor.advisor1ID | RODRIGUES, R. A. | pt_BR |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/7538420607868266 | pt_BR |
dc.contributor.referee1 | RODRIGUES, Rachel de Queiroz Ferreira. | - |
dc.contributor.referee1ID | RODRIGUES, R. Q. F. | pt_BR |
dc.contributor.referee2 | RIBEIRO, Rodrigo Alves. | - |
dc.contributor.referee2ID | RIBEIRO, R. A. | pt_BR |
dc.description.resumo | Na odontologia, as questões estéticas estão cada vez mais importantes. Os implantes dentários modernos surgiram a partir de pesquisas de Branemark e estão cada vez mais presentes no dia-a-dia clínico da área, sendo os do tipo cone morse e hexágono externo bastante difundidos. Os implantes são peças de titânio que se unem ao osso por meio de um mecanismo chamado osseointegração e cada sistema traz suas vantagens e desvantagens. A peri-implantite é uma infecção causada nos tecidos adjacentes ao implante devido ao acúmulo de biofilme por má higienização, que pode ser modificada por outros fatores, causando perda óssea, afetando estética e função dos implantes. Além dela, problemas como afrouxamento de parafuso e fratura também podem acometer os diversos sistemas de implantes. Avaliando Cone Morse e Hexágono externo em seus aspectos clínicos, foi possível concluir que o sistema CM se sobressai, segundo a bibliografia consultada. A presente revisão foi realizada entre o período de novembro de 2017 a julho de 2018, incluindo pesquisas, casos clínicos e também outras revisões de literatura encontradas nas plataformas Bireme, Pubmed e Scielo. Ela visou comparar, de acordo com uma revisão literária, os aspectos clínicos entre os sistemas cone morse e hexágono externo de implantes dentários. | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Centro de Saúde e Tecnologia Rural - CSTR | pt_BR |
dc.publisher.initials | UFCG | pt_BR |
dc.subject.cnpq | Odontologia | pt_BR |
dc.title | Cone morse x hexágono externo, vantagens e desvantagens no aspecto clíico: revisão de literatura. | pt_BR |
dc.date.issued | 2018-07-18 | - |
dc.description.abstract | In dentistry, aesthetic issues are increasingly important. Modern dental implants have emerged from Branemark researches and are increasingly present in the clinical dayto- day of the area, with the cone morse and external hexagons being quite widespread. Implants are titanium pieces that attach to the bone through a mechanism called osseointegration and each system brings its advantages and disadvantages. The periimplantite is an infection caused in the tissues adjacent to the implant due to the accumulation of biofilm by poor hygiene, which can be modified by other factors, causing bone loss, affecting aesthetics and function of the implants. In addition, problems such as loosening and fracture can also affect the various implant systems. Evaluating Cone Morse and external Hexagon in its clinical aspects was possible to conclude that the CM system excels according to the bibliography consulted. The present review was conducted between November 2017 and July 2018, including research, clinical cases and other literature reviews found on the Bireme, Pubmed and Scielo platform. It aimed to compare, according to a literary review, the clinical aspects between the cone morse and external hexagon systems of dental implants. | pt_BR |
dc.identifier.uri | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/25819 | - |
dc.date.accessioned | 2022-06-20T16:57:00Z | - |
dc.date.available | 2022-06-20 | - |
dc.date.available | 2022-06-20T16:57:00Z | - |
dc.type | Trabalho de Conclusão de Curso | pt_BR |
dc.subject | Implantodontia | pt_BR |
dc.subject | Morse | pt_BR |
dc.subject | Titânia | pt_BR |
dc.subject | Osseointegração | pt_BR |
dc.subject | Implantes dentários | pt_BR |
dc.subject | Estética dentária | pt_BR |
dc.subject | Peri-implantite | pt_BR |
dc.subject | Cone morse e hexágono externo | pt_BR |
dc.subject | Implantology | pt_BR |
dc.subject | Osseointegration | pt_BR |
dc.subject | Dental implants | pt_BR |
dc.subject | Dental aesthetics | pt_BR |
dc.subject | Peri-implantitis | pt_BR |
dc.subject | Morse cone and external hexagon | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.creator | SILVA, Randerson Mattheus Moura da. | - |
dc.publisher | Universidade Federal de Campina Grande | pt_BR |
dc.language | por | pt_BR |
dc.title.alternative | Morse taper x external hexagon, advantages and disadvantages in the clinical aspect: literature review. | pt_BR |
dc.identifier.citation | SILVA, Randerson Mattheus Moura da. Cone morse x hexágono externo, vantagens e desvantagens no aspecto clíico: revisão de literatura. 2018. 39f. Trabalho de Conclusão de Curso (Artigo), Curso de Bacharelado em Odontologia, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande - Patos - Paraíba - Brasil, 2018. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/25819 | pt_BR |
Appears in Collections: | Curso de Bacharelado em Odontologia - CSTR - Artigos |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
RANDERSON MATTHEUS MOURA - TCC ARTIGO ODONTOLOGIA CSTR 2018.pdf | Randerson Mattheus Moura da Silva - TCC Artigo Odontologia CSTR 2018 | 333.24 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.