Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26045
Full metadata record
DC FieldValueLanguage
dc.creator.IDNÓBREGA, W. F. S.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/1602521744449997pt_BR
dc.contributor.advisor1SARMENTO, Tássia Cristina de Almeida Pinto.-
dc.contributor.advisor1IDSARMENTO, T. C. A. P.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/8780072808231578pt_BR
dc.contributor.referee1ROSENDO, Rosana Araújo.-
dc.contributor.referee1IDROSENDO, R. A.pt_BR
dc.contributor.referee2RODRIGUES, Rachel de Queiroz Ferreira.-
dc.contributor.referee2IDRODRIGUES, R. Q. F.pt_BR
dc.description.resumoIntrodução: Atualmente, existe uma gama de localizadores eletrônicos disponíveis no mercado e, como era de se esperar, nem todos esses aparelhos são precisos na determinação do comprimento de trabalho. Objetivo: Realizar uma análise comparativa in vitro da precisão e confiabilidade de dois localizadores eletrônicos foraminais, na determinação do comprimento real do dente. Material e métodos: Foram utilizados no estudo 30 dentes extraídos. O comprimento real do dente foi mensurado com lima tipo K n°10 até o aparecimento da sua ponta rente ao forame, observado com lupa. Para mensuração eletrônica, foi utilizada base experimental preenchida com espuma floral e embebida em cloreto de sódio a 0,9%, na qual os dentes foram suportados. As mensurações foram realizadas com o Novapex e Joypex 5 em triplicata por dois examinadores previamente calibrados, tanto antes quanto após o preparo do terço cervical com brocas Gates Glidden. Os dados foram tabulados e analisados utilizando-se os testes t-Student e ANOVA one-way. Os localizadores foram classificados em Preciso, Aceitável, e Errôneo. Resultados: As médias de odontometria do Novapex e Joypex antes e após o preparo cervical diferiram minimamente entre si, não se observando diferenças estatísticas entre elas. A somatória dos escores preciso e aceitável, para o Novapex antes e após o preparo cervical foi de 79,9%, e para o Joypex, antes do preparo foi de 76,66% e após de 96,32, não havendo diferenças estatísticas entre os mesmos. Conclusão: Ambos os localizadores foram considerados capazes de determinar com precisão e confiabilidade o comprimento do canal radicular.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Saúde e Tecnologia Rural - CSTRpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqOdontologiapt_BR
dc.titleAnálise comparativa da precisão e confiabilidade de dois localizadores eletrônicos foraminais: um estudo in vitro.pt_BR
dc.date.issued2015-07-29-
dc.description.abstractIntroduction: Currently, there is a range of electronic locators on the market and, as was to be expected, not all of these devices are accurate in determining the working length. Objective: To conduct a comparative analysis in vitro accuracy and reliability of two electronic apex locators, in determining the real length of the tooth. Methods: Was used 30 extracted teeth in the study. The real length of the tooth was measured with a K file Nº 10 until the appearance of its tip close to the foramen, observed with magnifying glass. For electronic measurement was used experimental basis filled with floral foam and soaked in sodium chloride 0.9%, in which the teeth were supported. The measurements were made with Novapex and Joypex 5 in triplicate by two calibrated examiners, both before and after preparation of the cervical third with Gates Glidden drills. The data were tabulated and analyzed using the t-Student and ANOVA one-way tests. Locators were classified into Accurate, Acceptable, and Erroneous. Results: The average odontometry the Novapex and Joypex before and after cervical ripening differ minimally from each other, with no statistically significant differences between them. The sum of accurate and acceptable scores for Novapex before and after cervical ripening was 79.9%, and the Joypex before the preparation was 76.66% and after 96.32, with no statistical differences between the same. Conclusion: Both locators were considered capable of accurately and reliably determine the length of the root canal.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26045-
dc.date.accessioned2022-06-29T18:10:41Z-
dc.date.available2022-06-29-
dc.date.available2022-06-29T18:10:41Z-
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.subjectLocalizadores eletrônicos foraminaispt_BR
dc.subjectEstudo in vitropt_BR
dc.subjectOdontometriapt_BR
dc.subjectEndodontiapt_BR
dc.subjectÁpice dentáriopt_BR
dc.subjectElectronic foraminal locatorspt_BR
dc.subjectIn vitro studypt_BR
dc.subjectOdontometrypt_BR
dc.subjectEndodonticspt_BR
dc.subjectTooth apexpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorNÓBREGA, Waleska Fernanda Souto.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeComparative analysis of the accuracy and reliability of two electronic foraminal locators: an in vitro study.pt_BR
dc.identifier.citationNÓBREGA, Waleska Fernanda Souto. Análise comparativa da precisão e confiabilidade de dois localizadores eletrônicos foraminais: um estudo in vitro. 2015. 54f. Trabalho de Conclusão de Curso (Artigo), Curso de Bacharelado em Odontologia, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande - Patos - Paraíba - Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26045pt_BR
Appears in Collections:Curso de Bacharelado em Odontologia - CSTR - Artigos

Files in This Item:
File Description SizeFormat 
WALESKA FERNANDA SOUTO NÓBREGA - TCC ARTIGO ODONTOLOGIA CSTR 2015.pdf Waleska Fernanda Souto Nóbrega - TCC Artigo Odontologia CSTR 2015829.6 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.