Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2628
Full metadata record
DC FieldValueLanguage
dc.creator.IDLIMA JUNIOR, L. H. C.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/1091292824139717pt_BR
dc.contributor.advisor1FREIRE, Raimundo Carlos Silvério.-
dc.contributor.advisor1IDFREIRE, R.C.S.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4016576596215504pt_BR
dc.contributor.referee1MELO, Hiran de.-
dc.contributor.referee2ASSIS, Francisco Marcos de.-
dc.description.resumoNesta dissertação são apresentados os resultados de uma investigação da utilização da Lógica Paraconsistente anotada na medição e monitoramento da temperatura de um líquido aquecido por uma fonte de calor controlada. Na lógica paraconsistente anotada é necessário que se tenha à compreensão de como as imprecisões e incertezas ocorrem no processo de medição utilizando-se a instrumentação eletrônica, possibilitando a aferição da relevância e confiabilidade dos resultados obtidos através da aplicação da teoria da lógica paraconsistente. A característica fundamental da lógica paraconsistente é a de representar o manuseio de informações imprecisas, provendo um método de traduzir expressões verbais, vagas, imprecisas e qualitativas em valores numéricos. Apresenta-se um sistema projetado para a medição e o monitoramento da temperatura de um líquido no qual um microcontrolador é programado utilizando a lógica paraconsistente anotada de dois valores. Na medição da temperatura de um líquido utilizam-se dois pares de sensores que são distribuídos de modo a ressaltar as inconsistências das medidas. No monitoramento os sinais gerados pelos sensores, depois de processados por um conversor A/D, são analisados por meio de um algoritmo baseado na Lógica Paraconsistente. O controle da fonte de calor é efetuado por um sinal proveniente do microcontrolador após uma conversão D/A. Nos experimentos observou-se que os resultados das medidas de temperatura apresentavam uma exatidão de + I o C.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elértrica.-
dc.titleLógica para consistente anotada: aplicação na aquisição de dados de sensores de temperatura.pt_BR
dc.date.issued2003-12-
dc.description.abstractIn this dissertation are presented of the results of an investigation of the use the noted paraconsistente logic in the measurement and monitorization of the temperature of a warm liquid for a heat source. In the noted paraconsitente logic is necessary the comprehension of how the imprecision and uncertain occur in the measurement process use the electronic instrumentation, enabling of the relevance and reliance gauge of the results gathered through paraconsistente logic theory. The fundamental characteristic of the paraconsistente logic is its ability to represent the handling of inexact information, providing a method of translating verbal expressions, vacancies, imprecise and qualitative in numeric values. It is presented a projected system for the measurement and the monitorization of the temperature of a liquid in which a microtroller is programmed using the noted paraconsistente logic of two values. In the measurement of the temperature of a liquid was used two pairs or temperature sensors distributed from way to emphasize the inconsistencies of the measures. In the monitorization the sings generated by the temperature sensors, after having processed for a converter A/D are analyzed through an algorithm based on the paraconsistente logic. The control of heat source is made by an sign originating from the microcontroller after a conversion D/A. In the experiments it was observed that the results of the temperature measures presented an accuracy of + 1 °C.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2628-
dc.date.accessioned2019-01-30T10:45:15Z-
dc.date.available2019-01-30-
dc.date.available2019-01-30T10:45:15Z-
dc.typeDissertaçãopt_BR
dc.subjectLógica paraconsistente.-
dc.subjectSensores de temperatura.-
dc.subjectAquisição de dados.-
dc.subjectParaconsistory logic.-
dc.subjectTemperature sensors.-
dc.subjectData acquisition.-
dc.rightsAcesso Abertopt_BR
dc.creatorLIMA JÚNIOR, Luis Hermano Casado de-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeLogic for consistent annotation: application in data acquisition of temperature sensors.pt_BR
dc.identifier.citationLIMA JÚNIOR, Luis Hermano Casado de. Lógica para consistente anotada: aplicação na aquisição de dados de sensores de temperatura. 151f. 2003. (Dissertação de Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2003.pt_BR