Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26814
Full metadata record
DC FieldValueLanguage
dc.creator.IDOLIVEIRA, P. V. B.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/9946288244103459pt_BR
dc.contributor.advisor1NEVES, Washington Luiz Araújo.-
dc.contributor.advisor1IDNEVES, W. L. A.pt_BR
dc.contributor.advisor1IDNEVES, WASHINGTON L.A.pt_BR
dc.contributor.advisor1IDNEVES, WASHINGTON LUIZ ARAUJO.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3107104665517286pt_BR
dc.contributor.advisor2FERNANDES JÚNIOR, Damásio.-
dc.contributor.advisor2IDFERNANDES Jr., D.pt_BR
dc.contributor.advisor2IDFERNANDES, D.pt_BR
dc.contributor.advisor2IDFERNANDES, DAMÁSIO.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/3630883713661678pt_BR
dc.contributor.referee1SOUZA, Benemar Alencar de.-
dc.contributor.referee1IDSOUZA, B. A.pt_BR
dc.contributor.referee1IDDE SOUZA, BENEMAR ALENCAR.pt_BR
dc.contributor.referee1IDALENCAR DE SOUZA, BENEMAR.pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/4987294390789975pt_BR
dc.contributor.referee2BRITO, Núbia Silva Dantas.-
dc.contributor.referee2IDBRITO, Núbia Silva Dantas.pt_BR
dc.contributor.referee2IDBrito, N.S.D.pt_BR
dc.contributor.referee2IDBRITO, NUBIA S.D.pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/9319631147408039pt_BR
dc.description.resumoA influência do sistema de aquisição de dados sobre dois métodos de localização de faltas (de um e dois terminais), baseados em componentes fundamentais e sobre a proteção de distância é avaliada. Para tanto, um Transformador de Potencial Capacitivo (TPC), três filtros anti-aliasing e três conversores analógico/digital (A/D) com 8, 16 e 32 bits foram utilizados. Vários cenários de falta são simulados em um sistema elétrico de 230 kV mo- delado no Alternative Transients Program (ATP). Após cada simulação, os dados gerados foram gravados e posteriormente utilizados em rotinas computacionais desenvolvidas no MATLAB. Nas análises de localização de faltas, o local do curto-circuito é estimado uti- lizando como dados de entrada dos algoritmos localizadores os sinais de tensão e corrente do primário, secundário, secundário filtrado e os sinais digitalizados pelo conversor A/D, e os erros são calculados. Com relação à proteção de distância, a trajetória da impedância aparente, considerando os diferentes sinais oriundos do sistema de aquisição de dados, ao longo da característica mho do relé é traçada. Dos resultados obtidos, constata-se que as estimações dos locais de falta e as trajetórias da impedância são diretamente afetadas pelas respostas em frequência do TPC e dos filtros anti-aliasing, e também pelo erro introduzido durante a conversão A/D. Além disso, observa-se que conversores com 16 bits ou mais obtiveram desempenhos idênticos para as funções de proteção avaliadas.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétricapt_BR
dc.titleInfluência do sistema de aquisição de dados sobre algoritmos de proteção de distância e localização de faltas baseados em componentes fundamentais.pt_BR
dc.date.issued2019-03-08-
dc.description.abstractThe infuence of the data acquisition system on the performance of one- and two-ended fault location techniques and on distance protection is evaluated. Basically, one Coupling Capacitor Voltage Transformers (CCVT), three anti-aliasing Ąlters, and three analog-to- digital converters (ADC) with 8, 16, and 32 bits were taken into account. Several fault scenarios are performed in a 230 kV power system modelled in the Alternative Transients Program (ATP). After each simulation, the data generated were recorded and subsequen- tly evaluated in MATLAB. Routines. In the fault location analyses, the fault point was estimated using as input data to the locator algorithms the voltage and current signals from the primary, secondary, Ąltered secondary, and the signals sampled by the ADC, and the relative errors are computed. Regarding the distance protection, the apparent impe- dance trajectory was plotted, considering the diferent signals from the data acquisition system, over the mho relay characteristics. From the obtained results, it was veriĄed that the estimated fault locations and the impedance trajectory are directly afected by the CCVT and anti-aliasing Ąlters transient responses, and the error introduced by the ADC. Furthermore, it is possible to conclude that ADC with 16 bits or more achieved identical performances for the evaluated protection functions.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26814-
dc.date.accessioned2022-08-31T19:44:57Z-
dc.date.available2022-08-31-
dc.date.available2022-08-31T19:44:57Z-
dc.typeDissertaçãopt_BR
dc.subjectFaltas em linhas de transmissãopt_BR
dc.subjectComponentes fundamentaispt_BR
dc.subjectLocalização de faltaspt_BR
dc.subjectProteção de distânciapt_BR
dc.subjectSistema de aquisição de dadospt_BR
dc.subjectTransitórios eletromagnéticopt_BR
dc.subjectFaults in transmission linespt_BR
dc.subjectFundamental componentspt_BR
dc.subjectFault locationpt_BR
dc.subjectDistance protectionpt_BR
dc.subjectData acquisition systempt_BR
dc.subjectElectromagnetic transientspt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorOLIVEIRA, Paulo Vinicius Bezerra de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeInfluence of the data acquisition system on algorithms distance protection and fault location based on fundamental components.pt_BR
dc.identifier.citationOLIVEIRA, Paulo Vinicius Bezerra de. Influência do sistema de aquisição de dados sobre algoritmos de proteção de distância e localização de faltas baseados em componentes fundamentais. 2019. 86 fl. Dissertação (Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2019.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
PAULO VINICIUS BEZERRA DE OLIVEIRA - DISSERTAÇÃO (PPGEE) 2019.pdfPaulo Vinicius Bezerra de Oliveira - Dissertação (PPGEE) 2019.1.07 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.