Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/27067
Title: Análise comparativa entre métodos de detecção de faltas em linhas de transmissão do tipo HVDC.
Other Titles: Comparative analysis between fault detection methods in power lines HVDC type transmission.
???metadata.dc.creator???: LIMA, Harrison Batista de.
???metadata.dc.contributor.advisor1???: FERNANDES JUNIOR, Damásio.
???metadata.dc.contributor.advisor2???: NEVES, Washington Luiz Araujo.
???metadata.dc.contributor.referee1???: SOUZA, Benemar Alencar de.
???metadata.dc.contributor.referee2???: DANTAS, Karcius Marcelus Colaço.
Keywords: Linhas de transmissão – Falhas;Detecção de falhas – HVDC;Processamento de energia;Localização de faltas;Ondas Viajantes;Transmission lines - Faults;Fault Detection – HVDC;Energy processing;Fault location;Waves travelers
Issue Date: 12-Apr-2019
Publisher: Universidade Federal de Campina Grande
Citation: LIMA, Harrison Batista de. Análise comparativa entre métodos de detecção de faltas em linhas de transmissão do tipo HVDC. 2019. 90 fl. Dissertação (Mestrado em Engenharia Elétrica) – Universidade Federal de Campina Grande, Centro de Engenharia Elétrica E informática, Campina Grande - Paraíba - Brasil, 2019.
???metadata.dc.description.resumo???: Com o desenvolvimento de novos dispositivos na eletrônica de potência, a transmissão em corrente contínua vem se tornando cada vez mais comum, e seu uso é mais vantajoso em determinadas situações que a transmissão em corrente alternada. Baseado nessa importância, propõe-se realizar um estudo comparativo entre os métodos de detecção de faltas em linhas de transmissão de corrente contínua. Os métodos selecionados para o estudo comparativo pertencem ao grupo dos métodos baseados na teoria de ondas viajantes. Foram utilizados métodos que se baseiam na transformada wavelet discreta, na transformada wavelet discreta redundante, na transformada de Park e um método que se baseia na energia da derivada de sinais. O desempenho dos métodos foi analisado com base em simulações realizadas via MATLAB/Simulink de duas configurações diferentes de sistemas HVDC, um sistema monopolar e um bipolar. Nas análises para avaliar o desempenho dos métodos, foram variados os pontos de falta, o tipo de falta e a resistência de falta, a fim de testar a robustez dos métodos para faltas de alta e baixa impedância. Em todos os métodos avaliados, foi aplicado um limiar auto- adaptativo para detecção de faltas. A partir dos resultados, foi verificado que os métodos que obtiveram os melhores desempenhos foram os baseados na energia da derivada de sinais e o método que se baseia na transformada de Park. O método que se baseia da energia da derivada de sinais possui código mais simples, quando comparado com o método que se baseia na transformada de Park, realizando assim, a detecção de faltas de forma mais rápida.
Abstract: With the development of new devices in power electronics, direct current transmission is becoming more and more common, and its use is more advantageous in certain situations than the transmission in alternating current. Based on this importance, it is proposed to carry out a comparative study between the methods of detecting faults in direct current transmission lines. The selected methods for comparative study belong to the group of methods based on the theory of traveling wave. The methods used were those based on the discrete wavelet transform, the redundant discrete wavelet transform, the Park transform and a method based on the energy of the signal derivative. The performances of the methods are compared based on simulations performed via MATLAB/Simulink of two different configurations of HVDC systems, a monopolar and a bipolar system. In the analyses to evaluate the performance of the methods, the fault points, fault type and fault resistance were varied in order to test the robustness of the methods for high and low impedance faults. In all the evaluated methods, a self- adaptive threshold for fault detection was applied. From the results it was verified that the methods that obtained the bests results were those based on the energy of the signal derivative and the method based on the Park transform. The method based on signal derivative energy has simpler code, when compared to the method that makes use of the Park transform, thus performing the detection of faults faster.
Keywords: Linhas de transmissão – Falhas
Detecção de falhas – HVDC
Processamento de energia
Localização de faltas
Ondas Viajantes
Transmission lines - Faults
Fault Detection – HVDC
Energy processing
Fault location
Waves travelers
???metadata.dc.subject.cnpq???: Engenharia Elétrica
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/27067
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
HARRISON BATISTA DE LIMA - DISSERTAÇÃO (PPGEE) 2019.pdfHarrison Batista de Lima - Dissertação (PPGEE) 2019.2.72 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.