Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/27067
Full metadata record
DC FieldValueLanguage
dc.creator.IDLIMA, H. B.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6775866140633213pt_BR
dc.contributor.advisor1FERNANDES JUNIOR, Damásio.-
dc.contributor.advisor1IDFERNANDES Jr., D.pt_BR
dc.contributor.advisor1IDFERNANDES, D.pt_BR
dc.contributor.advisor1IDFERNANDES, DAMÁSIO.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3630883713661678pt_BR
dc.contributor.advisor2NEVES, Washington Luiz Araujo.-
dc.contributor.advisor2IDNEVES, W. L. Apt_BR
dc.contributor.advisor2IDNEVES, WASHINGTON L.A.pt_BR
dc.contributor.advisor2IDNEVES, W. L. A.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/3107104665517286pt_BR
dc.contributor.referee1SOUZA, Benemar Alencar de.-
dc.contributor.referee1IDSOUZA, B. A.pt_BR
dc.contributor.referee1IDDE SOUZA, BENEMAR ALENCAR.pt_BR
dc.contributor.referee1IDALENCAR DE SOUZA, BENEMAR.pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/4987294390789975pt_BR
dc.contributor.referee2DANTAS, Karcius Marcelus Colaço.-
dc.contributor.referee2IDDANTAS, K. M. C.pt_BR
dc.contributor.referee2IDDantas, Karcius Marcelus Colaço.pt_BR
dc.contributor.referee2IDDANTAS, KARCIUS M. C.pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/1881990103809201pt_BR
dc.description.resumoCom o desenvolvimento de novos dispositivos na eletrônica de potência, a transmissão em corrente contínua vem se tornando cada vez mais comum, e seu uso é mais vantajoso em determinadas situações que a transmissão em corrente alternada. Baseado nessa importância, propõe-se realizar um estudo comparativo entre os métodos de detecção de faltas em linhas de transmissão de corrente contínua. Os métodos selecionados para o estudo comparativo pertencem ao grupo dos métodos baseados na teoria de ondas viajantes. Foram utilizados métodos que se baseiam na transformada wavelet discreta, na transformada wavelet discreta redundante, na transformada de Park e um método que se baseia na energia da derivada de sinais. O desempenho dos métodos foi analisado com base em simulações realizadas via MATLAB/Simulink de duas configurações diferentes de sistemas HVDC, um sistema monopolar e um bipolar. Nas análises para avaliar o desempenho dos métodos, foram variados os pontos de falta, o tipo de falta e a resistência de falta, a fim de testar a robustez dos métodos para faltas de alta e baixa impedância. Em todos os métodos avaliados, foi aplicado um limiar auto- adaptativo para detecção de faltas. A partir dos resultados, foi verificado que os métodos que obtiveram os melhores desempenhos foram os baseados na energia da derivada de sinais e o método que se baseia na transformada de Park. O método que se baseia da energia da derivada de sinais possui código mais simples, quando comparado com o método que se baseia na transformada de Park, realizando assim, a detecção de faltas de forma mais rápida.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétricapt_BR
dc.titleAnálise comparativa entre métodos de detecção de faltas em linhas de transmissão do tipo HVDC.pt_BR
dc.date.issued2019-04-12-
dc.description.abstractWith the development of new devices in power electronics, direct current transmission is becoming more and more common, and its use is more advantageous in certain situations than the transmission in alternating current. Based on this importance, it is proposed to carry out a comparative study between the methods of detecting faults in direct current transmission lines. The selected methods for comparative study belong to the group of methods based on the theory of traveling wave. The methods used were those based on the discrete wavelet transform, the redundant discrete wavelet transform, the Park transform and a method based on the energy of the signal derivative. The performances of the methods are compared based on simulations performed via MATLAB/Simulink of two different configurations of HVDC systems, a monopolar and a bipolar system. In the analyses to evaluate the performance of the methods, the fault points, fault type and fault resistance were varied in order to test the robustness of the methods for high and low impedance faults. In all the evaluated methods, a self- adaptive threshold for fault detection was applied. From the results it was verified that the methods that obtained the bests results were those based on the energy of the signal derivative and the method based on the Park transform. The method based on signal derivative energy has simpler code, when compared to the method that makes use of the Park transform, thus performing the detection of faults faster.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/27067-
dc.date.accessioned2022-09-12T12:56:01Z-
dc.date.available2022-09-12-
dc.date.available2022-09-12T12:56:01Z-
dc.typeDissertaçãopt_BR
dc.subjectLinhas de transmissão – Falhaspt_BR
dc.subjectDetecção de falhas – HVDCpt_BR
dc.subjectProcessamento de energiapt_BR
dc.subjectLocalização de faltaspt_BR
dc.subjectOndas Viajantespt_BR
dc.subjectTransmission lines - Faultspt_BR
dc.subjectFault Detection – HVDCpt_BR
dc.subjectEnergy processingpt_BR
dc.subjectFault locationpt_BR
dc.subjectWaves travelerspt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorLIMA, Harrison Batista de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeComparative analysis between fault detection methods in power lines HVDC type transmission.pt_BR
dc.identifier.citationLIMA, Harrison Batista de. Análise comparativa entre métodos de detecção de faltas em linhas de transmissão do tipo HVDC. 2019. 90 fl. Dissertação (Mestrado em Engenharia Elétrica) – Universidade Federal de Campina Grande, Centro de Engenharia Elétrica E informática, Campina Grande - Paraíba - Brasil, 2019.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
HARRISON BATISTA DE LIMA - DISSERTAÇÃO (PPGEE) 2019.pdfHarrison Batista de Lima - Dissertação (PPGEE) 2019.2.72 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.