dc.description.resumoEsta pesquisa visa analisar as manifestações patológicas de uma edificação multifamiliar localizada na cidade de Pombal/PB. Trata-se de um estudo de caso, no qual foi realizada a inspeção predial devido a existência de manifestações patológicas. Utilizando a metodologia da norma de inspeção predial do Instituto Brasileiro de Avaliações e Perícias de Engenharia de São Paulo, pôde-se categorizar as manifestações patológicas, no qual foram identificados problemas como desagregação do concreto, corrosão de armaduras, trincas e fissuras, problemas em forros, problemas relacionados a umidade, problemas em instalações hidráulicas e sanitárias, problemas com esquadrias, problemas com instalações elétricas, acessibilidade e no sistema de combate a incêndio, e com isso sugerir medidas de prevenção e correção. Seguindo o método IBAPE, foi analisado o grau de risco (critico, médio e mínimo) das anomalias, e em 19% dos casos as anomalias são consideradas críticas, 24% são de nível médio, e 57% de nível mínimo e com relação aos tipos de anomalias, 38% dos casos são do tipo endógenos, 33% são funcionais e 29% do tipo funcionais. Também foi utilizada a matriz GUT para definir a ordem de prioridade das manifestações patológicas. Por não haver registros de manutenção, a edificação encontra-se com desconformidades e necessita de manutenção imediata e um plano de vistoria, levando em consideração normas vigentes e sendo realizada por profissionais capacitados. Por fim o trabalho mostra a importância da inspeção predial como meio adequado para a manutenção das edificações.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia Agroalimentar - CCTApt_BR
dc.publisher.initialsUFCGpt_BR
dc.titleEstudo de manifestações patológicas em edificação multifamiliar localizada na cidade de Pombal – PB.pt_BR
dc.date.issued2022-08-24-
dc.description.abstractThis research aimed to analyze the pathological manifestations of a multifamily building located in the city of Pombal/PB. This is a case study, in which the building inspection was carried out due to the existence of pathological manifestations. Using the methodology of the building inspection standard of the Instituto Brasileiro de Avaliação e Perícias de Engenharia de São Paulo, it is possible to categorize the pathological manifestations, in which problems such as concrete disintegration, corrosion of reinforcement, cracks and fissures, problems in ceilings were identified. Problems related to humidity, problems with hydraulic and sanitary installations, problems with frames, problems with electrical installations, accessibility and in the fire fighting system, and with that to suggest preventive and corrective measures. Based on the inspection carried out, the building showed irregularities regarding the fire fighting system, as well as the structural system. Following the IBAPE method, the degree of risk (critical, medium and minimum) of the anomalies was analyzed and in 19% of the cases the anomalies are considered critical, 24% are of medium level, and 57% of minimum level and in relation to the types of anomalies, 38% of the cases are of the endogenous type, 33% are functional and 29% of the functional type. The GUT matrix was also used to define the order of priority of pathological manifestations. As there are no maintenance records, the building has nonconformities and needs immediate maintenance and an inspection plan, taking into account current regulations and being carried out by trained professionals. Finally, the work shows the importance of building inspection as an adequate means for the maintenance of buildings.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/27080-
dc.date.accessioned2022-09-12T16:37:59Z-
dc.date.available2022-09-12-
dc.date.available2022-09-12T16:37:59Z-
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.subjectConstrução Civil - Manifestação patológicapt_BR
dc.subjectCivil Construction - Pathological Manifestationpt_BR
dc.subjectInspeção predialpt_BR
dc.subjectBuilding inspectionpt_BR
dc.subjectEdificação multifamiliarpt_BR
dc.subjectMulti-family buildingpt_BR
dc.subjectManutenção predialpt_BR
dc.subjectBuilding maintenancept_BR
dc.rightsAcesso Abertopt_BR
dc.creatorCAVALCANTE SEGUNDO, João Araújo.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeStudy of pathological manifestations in a multifamily building located in the city of Pombal - PB.pt_BR
dc.identifier.citationCAVALCANTE SEGUNDO, João Araújo. Estudo de manifestações patológicas em edificação multifamiliar localizada na cidade de Pombal – PB. 2022. 73 f. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Civil) - Centro de Ciências e Tecnologia Agroalimentar, Universidade Federal de Campina Grande, Pombal, Paraíba, Brasil, 2022.pt_BR