Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/27131
Full metadata record
DC FieldValueLanguage
dc.creator.IDMELO, Y. M. P.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/9058258694004525pt_BR
dc.contributor.advisor1NEVES, Washington Luiz Araújo.-
dc.contributor.advisor1IDNEVES, W. L. A.pt_BR
dc.contributor.advisor1IDNEVES, WASHINGTON L.A.pt_BR
dc.contributor.advisor1IDNEVES, WASHINGTON LUIZ ARAUJO.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3107104665517286pt_BR
dc.contributor.advisor2FERNANDES JÚNIOR, Damásio.-
dc.contributor.advisor2IDFERNANDES Jr., D.pt_BR
dc.contributor.advisor2IDFERNANDES, D.pt_BR
dc.contributor.advisor2IDFERNANDES, DAMÁSIO.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/3630883713661678pt_BR
dc.contributor.referee1VIEIRA JÚNIOR, José Carlos de Melo.-
dc.contributor.referee1IDVIEIRA JUNIOR, J. C. M.pt_BR
dc.contributor.referee1IDVIEIRA, J.pt_BR
dc.contributor.referee1IDVieira, Jose C.M.pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/1047893003118791pt_BR
dc.contributor.referee2COSTA, Flávio Bezerra.-
dc.contributor.referee2IDCOSTA, F. B.pt_BR
dc.contributor.referee2IDCOSTA, FLAVIO B.pt_BR
dc.contributor.referee2IDCosta, Flávio Bezerra.pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/7510091283933216pt_BR
dc.contributor.referee3SOUZA, Benemar Alencar de.-
dc.contributor.referee3IDSOUZA, B. A.pt_BR
dc.contributor.referee3IDDE SOUZA, BENEMAR ALENCAR.pt_BR
dc.contributor.referee3IDALENCAR DE SOUZA, BENEMAR.pt_BR
dc.contributor.referee3Latteshttp://lattes.cnpq.br/4987294390789975pt_BR
dc.contributor.referee4BRITO, Núbia Silva Dantas.-
dc.contributor.referee4IDBRITO, Núbia Silva Dantas.pt_BR
dc.contributor.referee4IDBRITO, NUBIA S.D.pt_BR
dc.contributor.referee4IDBRITO, NUBIA.pt_BR
dc.contributor.referee4Latteshttp://lattes.cnpq.br/9319631147408039pt_BR
dc.contributor.referee5MOTA, Wellington Santos.-
dc.contributor.referee5IDMOTA, W. S.pt_BR
dc.contributor.referee5IDWellington S. Mota.pt_BR
dc.contributor.referee5IDMota, Wellington Santos.pt_BR
dc.contributor.referee5Latteshttp://lattes.cnpq.br/5452666875321325pt_BR
dc.description.resumoNeste trabalho de tese a transmissão de energia em corrente contínua é estudada e a principal contribuição é o desenvolvimento de um novo algoritmo para a detecção de faltas em linhas de transmissão em corrente contínua. Este método utiliza os dados sincronizados de tensão e corrente, e desta maneira a detecção de faltas é realizada de forma redundante. Além disso, o método atua em conjunto com um método clássico de localização e classificação de faltas em linhas de transmissão, baseado na teoria de ondas viajantes. São simuladas quatro configurações de sistemas de transmissão de energia elétrica em alta tensão e corrente contínua, sendo um sistema monopolar, um sistema bipolar, um sistema híbrido compostos por linhas em corrente contínua e alternada, e um sistema multiterminal. O método de detecção de faltas desenvolvido utiliza o cálculo da derivada de sinais, cálculo da energia de coeficientes e um limiar auto-adaptativo. Os resultados são analisados considerando-se os erros absolutos, percentuais e os erros admissíveis. Por fim, observa-se que os erros percentuais obtidos na localização de faltas não são superiores a 0,33% para o sistema monopolar, 0,82% para o sistema bipolar e 0,56% para o sistema híbrido, ou seja, 0,82% é o erro percentual máximo para todos os 1980 casos de faltas analisados, mesmo para os casos com alto valor de resistência de falta. As faltas são detectadas corretamente em 100% dos casos simulados das faltas nos sistemas monopolar, bipolar e híbrido. O método proposto se destaca por apresentar resultados semelhantes aos de transformadas renomadas, como a wavelet, utilizando um limiar auto-adaptativo e a redundância entre os sinais de corrente e tensão.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétricapt_BR
dc.titleUma técnica para detecção de faltas em linhas de transmissão de corrente contínua por meio da energia da derivada de sinais.pt_BR
dc.date.issued2018-12-18-
dc.description.abstractIn this work the energy transmission is studied and the main contribution is the development of a new algorithm for fault detection in direct current (DC) transmission lines. This method uses the synchronized voltage and current data, so that fault detection is performed redundantly. In addition, a classical method of fault location and classification on transmission lines is applied together to the proposed detection method. The location method is based on the theory of traveling waves. Three configurations of electric power transmission systems using High Voltage Direct Current (HVDC) technology are simulated: a monopolar system, a bipolar system and a hybrid system composed of alternating current (AC) and DC lines, and a multiterminal system. The developed fault detection method uses the signals derivative calculation, energy calculation of coefficients and a self-adaptive threshold. The results are analyzed considering absolute errors, percentages and admissible errors. Finally, it is observed that the percentage errors obtained in the fault location are not higher than 0.33% for the monopolar system, 0.82% for the bipolar system, and 0.56% for the hybrid system, so, 0.82% is the maximum percentage error for all 1980 cases of analyzed faults, even for cases with high value of fault resistance. Faults are correctly detected at 100% of the simulated cases of faults in monopolar, bipolar and hybrid. The proposed method stands out for presenting similar results to well known transforms, such as wavelet, and using a self-adaptive threshold and redundancy.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/27131-
dc.date.accessioned2022-09-13T17:37:45Z-
dc.date.available2022-09-13-
dc.date.available2022-09-13T17:37:45Z-
dc.typeTesept_BR
dc.subjectLinhas de transmissãopt_BR
dc.subjectHVDCpt_BR
dc.subjectDerivada de sinaispt_BR
dc.subjectDetecção de faltaspt_BR
dc.subjectLocalização de faltaspt_BR
dc.subjectOndas viajantespt_BR
dc.subjectTransmission linespt_BR
dc.subjectDerivative of signalspt_BR
dc.subjectFault detectionpt_BR
dc.subjectLocation of faultspt_BR
dc.subjectTraveling wavespt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorMELO, Yonatha Marques Pereira de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeA technique for fault detection in transmission lines of direct current through the energy of the derivative of signals.pt_BR
dc.identifier.citationMELO, Yonatha Marques Pereira de. Uma técnica para detecção de faltas em linhas de transmissão de corrente contínua por meio da energia da derivada de sinais. 2018. 121 fl. Tese (Doutorado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2018.pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
YONATHA MARQUES PEREIRA DE MELO - TESE (PPGEE) 2018.pdfYonatha Marques Pereira de Melo - Tese (PPGEE) 2018.1.36 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.