Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/27141
Full metadata record
DC FieldValueLanguage
dc.creator.IDRAPHAEL L. A. REIS.pt_BR
dc.creator.IDR. REIS.pt_BR
dc.creator.IDR. L. A. REIS.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/1139577841043865pt_BR
dc.contributor.advisor1NEVES, Washington Luiz Araújo.-
dc.contributor.advisor1IDNEVES, W. L. Apt_BR
dc.contributor.advisor1IDNEVES, WASHINGTON L.A.pt_BR
dc.contributor.advisor1IDNEVES, W. L. A.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3107104665517286pt_BR
dc.contributor.advisor2FERNANDES JUNIOR, Damásio.-
dc.contributor.advisor2IDFERNANDES Jr., D.pt_BR
dc.contributor.advisor2IDFERNANDES, D.pt_BR
dc.contributor.advisor2IDFERNANDES, DAMÁSIO.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/3630883713661678pt_BR
dc.contributor.referee1BARROS, Maria Teresa Correia de.-
dc.contributor.referee1IDBARROS, M. T. C.pt_BR
dc.contributor.referee1IDCORREIA DE BARROS, M.T.pt_BR
dc.contributor.referee1IDBARROS, M.T. CORREIA DE.pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/6602027103257722pt_BR
dc.contributor.referee2COSTA, Flavio Bezerra.-
dc.contributor.referee2IDCOSTA, F. B.pt_BR
dc.contributor.referee2IDCosta, Flávio Bezerra.pt_BR
dc.contributor.referee2IDCosta, F.B.pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/7510091283933216pt_BR
dc.contributor.referee3CARDOSO JUNIOR, Ghendy.-
dc.contributor.referee3IDCARDOSO Jr., G.pt_BR
dc.contributor.referee3IDCardoso, Ghendy.pt_BR
dc.contributor.referee3IDCardoso, G.pt_BR
dc.contributor.referee3Latteshttp://lattes.cnpq.br/6284386218725402pt_BR
dc.contributor.referee4SOUZA, Benemar Alencar de.-
dc.contributor.referee4IDSOUZA, B. A.pt_BR
dc.contributor.referee4IDSouza, B.A.pt_BR
dc.contributor.referee4IDDE SOUZA, BENEMAR ALENCAR.pt_BR
dc.contributor.referee4Latteshttp://lattes.cnpq.br/4987294390789975pt_BR
dc.contributor.referee5BRITO, Nubia Silva Dantas.-
dc.contributor.referee5IDBRITO, Núbia Silva Dantaspt_BR
dc.contributor.referee5IDBrito, Núbia Silva Dantaspt_BR
dc.contributor.referee5IDBrito, N.S.D.pt_BR
dc.contributor.referee5Latteshttp://lattes.cnpq.br/9319631147408039pt_BR
dc.description.resumoUm novo método para localização de curtos-circuitos no domínio do tempo utilizando dados de apenas um terminal monitorado da linha de transmissão (LT) é proposto nesta tese. O algoritmo faz uso dos coeficientes de tensão e corrente obtidos da transformada de Park para estimar o local do distúrbio. No caso de faltas aterradas, apenas ondas incidentes de corrente são utilizadas, enquanto que, para os demais casos, uma função de correlação é usada para determinar o tempo de atraso entre o primeiro surto refletido do terminal monitorado e o surto subsequente refletido no ponto de ocorrência do distúrbio. Este atraso é utilizado para estimar o local do curto-circuito. A avaliação do método é realizada por meio de simulações digitais. A validação é realizada por meio de comparações com os desempenhos de um relé numérico real que opera com funções no domínio do tempo, bem como de algoritmos de um e dois terminais baseados na teoria de ondas viajantes reportados na literatura. Dos resultados obtidos, constata-se a eficiência do método em se localizar distúrbios em LT com dados de apenas um terminal, mesmo nos casos críticos em que altos valores de resistência e ângulo de incidência igual a 0◦ são considerados, conduzindo a falha de métodos usuais. Além disso, uma significativa economia de recursos será alcançada por não necessitar de canais de comunicação e seus dispositivos associados. Em outra vertente, contribuições nas análises de sensibilidade de cinco modelos digitais de transformadores de potencial capacitivos (TPC) para estudos de proteção são apresentadas, destacando as alterações nas respectivas respostas em frequência, inclusive nas de fase, as quais normalmente não são reportadas na literatura. Adicionalmente, um estudo original de análises estatísticas dos erros obtidos nos processos de localização de faltas é realizado, demonstrando que o conjunto total de erros pode ser aproximado por uma função com distribuição de probabilidade normal.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétricapt_BR
dc.titleAprimoramento de soluções de localização de curtos-circuitos em linhas de transmissão.pt_BR
dc.date.issued2019-08-07-
dc.description.abstractA new single-ended traveling wave (TW)-based fault location method is proposed in this work. It uses the voltage and current signals obtained through the Park’s transformation to estimate the fault distance. For ungrounded short-circuit cases, a correlation function is applied to compute the time delay between the fault-induced incident and reflected waves, whereas the incident direct (aerial)- and zero-mode current components are used for grounded disturbances. The proposed algorithm evaluations are performed through digital simulations. Its validation is carried out by comparisons with the performance of an actual numerical relay equipped with one-terminal TW-based fault location functions, and with the performance of one- and two-ended TW-based fault locators reported in the literature. From the obtained results, the efficiency in locating faults with single-ended measurements by the proposed technique is quite acceptable, even for zero-crossing fault inception angle scenarios and high fault resistances, which are usually reported as limiting factors for this kind of routines. Besides, a significant saving of economic resources are achieved since the use of the proposed algorithm does not require any communication means and their associated devices. In another strand, contributions on sensitivity analysis of five EMTP-based coupling capacitive voltage transformers (CCVT) digital models for protection studies are presented, in which their frequency response changing due to modeling errors or CCVT aging are shown, including the phase response, which is not often reported in the literature. Additionally, an original study of statistical analysis using the obtained fault location estimated errors is performed, attesting that the total error points can be approximated by a function with normal probability distribution.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/27141-
dc.date.accessioned2022-09-13T18:38:57Z-
dc.date.available2022-09-13-
dc.date.available2022-09-13T18:38:57Z-
dc.typeTesept_BR
dc.subjectLinhas de Transmissãopt_BR
dc.subjectLocalização de Curtos-circuitospt_BR
dc.subjectMedições de um Terminalpt_BR
dc.subjectOndas Viajantespt_BR
dc.subjectProteção de Sistemas Elétricospt_BR
dc.subjectTransformadores para Instrumentospt_BR
dc.subjectTransmission linespt_BR
dc.subjectShort-circuit locationpt_BR
dc.subjectMeasurements of a Terminalpt_BR
dc.subjectTraveling Wavespt_BR
dc.subjectProtection of Electrical Systemspt_BR
dc.subjectTransformers for Instrumentspt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorREIS, Raphael Leite de Andrade.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeImprovement of short-circuit location solutions in transmission lines.pt_BR
dc.identifier.citationREIS, Raphael Leite de Andrade. Aprimoramento de soluções de localização de curtos-circuitos em linhas de transmissão. 20192. 133 fl. Tese (Doutorado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2019.pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
RAPHAEL LEITE DE ANDRADE REIS - TESE (PPGEE) 2019.pdfRaphael Leite de Andrade Reis - Tese (PPGEE) 2019.11.48 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.